1.
Comput Methods Programs Biomed ; 193: 105526, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32402845

RESUMO

BACKGROUND AND OBJECTIVE: Patients are required to support their cheeks during breath-occluding lung function tests. This prevents cheek expansion which would alter pressure measured at the mouth, and, consequently, lung mechanics measurements. To date, the effect of cheek support on airway resistance measurements has been assessed. However other lung mechanics have not been studied as thoroughly, and no algorithm to account for the effect of missing cheek support on lung mechanics measurements has been developed. METHODS: Lung mechanics were assessed with a breath occlusion test during light panting in healthy subjects with and without cheek support in a body plethysmograph. Average model-based airway resistance, lung elastance, and a parameter representing the viscoelastic were measured. Results were compared to quantify the effect of cheek support on these three parameters. RESULTS: In the nine healthy subjects (5 Female, 4 Male) recruited for this study, all mechanics tended to be underestimated when cheeks were unsupported. Changes in elastance, resistance, and viscoelastic parameter ranged between 1.6-66.8 %, -4.5-21.8 %, and -4.7-68.2 %, respectively, when cheek support was added. The underestimation was due to reduced mouth pressure during cheek expansion when the breath was occluded. The variance of lung mechanics parameters did not change with cheek support in all subjects. CONCLUSIONS: The error in lung mechanics measurement caused by unsupported cheeks was subject dependent. Hence, no rule-of-thumb could be identified to reconstruct missing cheek support. For correct lung mechanics measurements during breath-occluding lung tests, patients must have adequate cheek support. ABBREVIATIONS: ROCC: Occlusion resistance; COPD: Chronic Obstructive Pulmonary Disorder; SB: spontaneous breathing.


Assuntos
Resistência das Vias Respiratórias , Pulmão , Bochecha , Feminino , Humanos , Masculino , Testes de Função Respiratória , Mecânica Respiratória
2.
Comput Methods Programs Biomed ; 186: 105184, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31715280

RESUMO

BACKGROUND AND OBJECTIVE: Model-based lung mechanics monitoring can provide clinically useful information for guiding mechanical ventilator treatment in intensive care. However, many methods of measuring lung mechanics are not appropriate for both fully and partially sedated patients, and are unable provide lung mechanics metrics in real-time. This study proposes a novel method of using lung mechanics identified during passive expiration to estimate inspiratory lung mechanics for spontaneously breathing patients. METHODS: Relationships between inspiratory and expiratory modeled lung mechanics were identified from clinical data from 4 fully sedated patients. The validity of these relationships were assessed using data from a further 4 spontaneously breathing patients. RESULTS: For the fully sedated patients, a linear relationship was identified between inspiratory and expiratory elastance, with slope 1.04 and intercept 1.66. The r value of this correlation was 0.94. No cohort-wide relationship was determined for airway resistance. Expiratory elastance measurements in spontaneously breathing patients were able to produce reasonable estimates of inspiratory elastance after adjusting for the identified difference between them. CONCLUSIONS: This study shows that when conventional methods fail, typically ignored expiratory data may be able to provide clinicians with the information needed about patient condition to guide MV therapy.


Assuntos
Expiração , Inalação , Respiração , Resistência das Vias Respiratórias , Humanos , Modelos Biológicos , Respiração Artificial
3.
Morphologie ; 103(343): 131-138, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31570307

RESUMO

The understanding or prediction of specific functions of the lung can be made using compact models that have identifiable parameters and that are custom designed to the problem of interest. However, when structure contributes to function - as is the case with most lung pathologies - structure-based, biophysical models become essential. Here we describe the application of structure-based models within the lung Physiome framework to identifying and explaining patient risk in 12patients diagnosed with acute pulmonary embolism. The model integrates perfusion, ventilation, and gas exchange to predict arterial blood gases and pulmonary artery pressure in individual patient models in response to patient-specific blood clot distribution, with full or partial arterial occlusion. The necessity for a patient-specific approach with biophysical models that account for scale-specific structure and function is demonstrated.


Assuntos
Pulmão/fisiologia , Modelos Anatômicos , Modelos Biológicos , Fenômenos Biofísicos , Humanos , Pulmão/anatomia & histologia , Interface Usuário-Computador
4.
Comput Methods Programs Biomed ; 171: 41-51, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30344050

RESUMO

BACKGROUND: Model-based glycaemic control protocols have shown promise in neonatal intensive care units (NICUs) for reducing both hyperglycaemia and insulin-therapy driven hypoglycaemia. However, current models for the appearance of glucose from enteral feeding are based on values from adult intensive care cohorts. This study aims to determine enteral glucose appearance model parameters more reflective of premature infant physiology. METHODS: Peaks in CGM data associated with enteral milk feeds in preterm and term infants are used to fit a two compartment gut model. The first compartment describes glucose in the stomach, and the half life of gastric emptying is estimated as 20 min from literature. The second compartment describes glucose in the small intestine, and absorption of glucose into the blood is fit to CGM data. Two infant cohorts from two NICUs are used, and results are compared to appearances derived from data in highly controlled studies in literature. RESULTS: The average half life across all infants for glucose absorption from the gut to the blood was 50 min. This result was slightly slower than, but of similar magnitude to, results derived from literature. No trends were found with gestational or postnatal age. Breast milk fed infants were found to have a higher absorption constant than formula fed infants, a result which may reflect known differences in gastric emptying for different feed types. CONCLUSIONS: This paper presents a methodology for estimation of glucose appearance due to enteral feeding, and model parameters suitable for a NICU model-based glycaemic control context.


Assuntos
Absorção Gastrointestinal , Glucose/análise , Recém-Nascido Prematuro , Algoritmos , Simulação por Computador , Índice Glicêmico , Humanos , Recém-Nascido , Modelos Biológicos
5.
Comput Methods Programs Biomed ; 165: 77-87, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30337083

RESUMO

BACKGROUND AND OBJECTIVES: Mechanical ventilation (MV) is a primary therapy for patients with acute respiratory failure. However, poorly selected ventilator settings can cause further lung damage due to heterogeneity of healthy and damaged alveoli. Varying positive-end-expiratory-pressure (PEEP) to a point of minimum elastance is a lung protective ventilator strategy. However, even low levels of PEEP can lead to ventilator induced lung injury for individuals with highly inflamed pulmonary tissue. Hence, models that could accurately predict peak inspiratory pressures after changes to PEEP could improve clinician confidence in attempting potentially beneficial treatment strategies. METHODS: This study develops and validates a physiologically relevant respiratory model that captures elastance and resistance via basis functions within a well-validated single compartment lung model. The model can be personalised using information available at a low PEEP to predict lung mechanics at a higher PEEP. Proof of concept validation is undertaken with data from four patients and eight recruitment manoeuvre arms. RESULTS: Results show low error when predicting upwards over the clinically relevant pressure range, with the model able to predict peak inspiratory pressure with less than 10% error over 90% of the range of PEEP changes up to 12 cmH2O. CONCLUSIONS: The results provide an in-silico model-based means of predicting clinically relevant responses to changes in MV therapy, which is the foundation of a first virtual patient for MV.


Assuntos
Modelos Biológicos , Respiração Artificial/métodos , Mecânica Respiratória , Interface Usuário-Computador , Adulto , Idoso , Resistência das Vias Respiratórias/fisiologia , Simulação por Computador , Feminino , Humanos , Complacência Pulmonar/fisiologia , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva/efeitos adversos , Respiração com Pressão Positiva/métodos , Respiração com Pressão Positiva/estatística & dados numéricos , Respiração Artificial/efeitos adversos , Respiração Artificial/estatística & dados numéricos , Síndrome do Desconforto Respiratório/terapia , Mecânica Respiratória/fisiologia , Lesão Pulmonar Induzida por Ventilação Mecânica/prevenção & controle
6.
Math Biosci ; 284: 21-31, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27301378

RESUMO

Randomised control trials have sought to seek to improve mechanical ventilation treatment. However, few trials to date have shown clinical significance. It is hypothesised that aside from effective treatment, the outcome metrics and sample sizes of the trial also affect the significance, and thus impact trial design. In this study, a Monte-Carlo simulation method was developed and used to investigate several outcome metrics of ventilation treatment, including 1) length of mechanical ventilation (LoMV); 2) Ventilator Free Days (VFD); and 3) LoMV-28, a combination of the other metrics. As these metrics have highly skewed distributions, it also investigated the impact of imposing clinically relevant exclusion criteria on study power to enable better design for significance. Data from invasively ventilated patients from a single intensive care unit were used in this analysis to demonstrate the method. Use of LoMV as an outcome metric required 160 patients/arm to reach 80% power with a clinically expected intervention difference of 25% LoMV if clinically relevant exclusion criteria were applied to the cohort, but 400 patients/arm if they were not. However, only 130 patients/arm would be required for the same statistical significance at the same intervention difference if VFD was used. A Monte-Carlo simulation approach using local cohort data combined with objective patient selection criteria can yield better design of ventilation studies to desired power and significance, with fewer patients per arm than traditional trial design methods, which in turn reduces patient risk. Outcome metrics, such as VFD, should be used when a difference in mortality is also expected between the two cohorts. Finally, the non-parametric approach taken is readily generalisable to a range of trial types where outcome data is similarly skewed.


Assuntos
Modelos Teóricos , Método de Monte Carlo , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Respiração Artificial/estatística & dados numéricos , Tamanho da Amostra , Humanos
7.
Math Biosci ; 284: 61-70, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27590773

RESUMO

BACKGROUND: Models of human glucose-insulin physiology have been developed for a range of uses, with similarly different levels of complexity and accuracy. STAR (Stochastic Targeted) is a model-based approach to glycaemic control. Elevated blood glucose concentrations (hyperglycaemia) are a common complication of stress and prematurity in very premature infants, and have been associated with worsened outcomes and higher mortality. This research identifies and validates the model parameters for model-based glycaemic control in neonatal intensive care. METHODS: C-peptide, plasma insulin, and BG from a cohort of 41 extremely pre-term (median age 27.2 [26.2-28.7] weeks) and very low birth weight infants (median birth weight 839 [735-1000] g) are used alongside C-peptide kinetic models to identify model parameters associated with insulin kinetics in the NICING (Neonatal Intensive Care Insulin-Nutrition-Glucose) model. A literature analysis is used to determine models of kidney clearance and body fluid compartment volumes. The full, final NICING model is validated by fitting the model to a cohort of 160 glucose, insulin, and nutrition data records from extremely premature infants from two different NICUs (neonatal intensive care units). RESULTS: Six model parameters related to insulin kinetics were identified. The resulting NICING model is more physiologically descriptive than prior model iterations, including clearance pathways of insulin via the liver and kidney, rather than a lumped parameter. In addition, insulin diffusion between plasma and interstitial spaces is evaluated, with differences in distribution volume taken into consideration for each of these spaces. The NICING model was shown to fit clinical data well, with a low model fit error similar to that of previous model iterations. CONCLUSIONS: Insulin kinetic parameters have been identified, and the NICING model is presented for glycaemic control neonatal intensive care. The resulting NICING model is more complex and physiologically relevant, with no loss in bedside-identifiability or ability to capture and predict metabolic dynamics.


Assuntos
Glicemia , Lactente Extremamente Prematuro/sangue , Recém-Nascido de Baixo Peso/sangue , Insulina/sangue , Terapia Intensiva Neonatal , Modelos Biológicos , Humanos , Recém-Nascido
8.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 2717-2720, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28268881

RESUMO

Cardiac output is an important variable when monitoring hemodynamic status. In particular, changes in cardiac output represent the goal of several circulatory management therapies. Unfortunately, cardiac output is very difficult to estimate, either in experimental or clinical settings. The goal of this work is to compare four techniques to measure cardiac output: pressure-volume catheter, aortic flow probe, thermodilution, and the PiCCO monitor. These four techniques were simultaneously used during experiments of fluid and endotoxin administration on 7 pigs. Findings show that, first, each individual technique is precise, with a relative coefficient of repeatability lower than 7 %. Second, 1 cardiac output estimate provided by any technique relates poorly to the estimates from the other 3, even if there is only small bias between the techniques. Third, changes in cardiac output detected by one technique are only detected by the others in 62 to 100 % of cases. This study confirms the difficulty of obtaining a reliable clinical cardiac output measurement. Therefore, several measurements using different techniques should be performed, if possible, and all such should be treated with caution.


Assuntos
Débito Cardíaco , Monitorização Fisiológica/métodos , Animais , Aorta , Catéteres , Hemodinâmica , Pressão , Suínos , Termodiluição
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 1005-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26736434

RESUMO

Accurate Stroke Volume (SV) monitoring is essential for patient with cardiovascular dysfunction patients. However, direct SV measurements are not clinically feasible due to the highly invasive nature of measurement devices. Current devices for indirect monitoring of SV are shown to be inaccurate during sudden hemodynamic changes. This paper presents a novel SV estimation using readily available aortic pressure measurements and aortic cross sectional area, using data from a porcine experiment where medical interventions such as fluid replacement, dobutamine infusions, and recruitment maneuvers induced SV changes in a pig with circulatory shock. Measurement of left ventricular volume, proximal aortic pressure, and descending aortic pressure waveforms were made simultaneously during the experiment. From measured data, proximal aortic pressure was separated into reservoir and excess pressures. Beat-to-beat aortic characteristic impedance values were calculated using both aortic pressure measurements and an estimate of the aortic cross sectional area. SV was estimated using the calculated aortic characteristic impedance and excess component of the proximal aorta. The median difference between directly measured SV and estimated SV was -1.4ml with 95% limit of agreement +/- 6.6ml. This method demonstrates that SV can be accurately captured beat-to-beat during sudden changes in hemodynamic state. This novel SV estimation could enable improved cardiac and circulatory treatment in the critical care environment by titrating treatment to the effect on SV.


Assuntos
Volume Sistólico , Animais , Aorta , Pressão Arterial , Estudos Transversais , Hemodinâmica , Suínos
10.
Obes Surg ; 24(1): 62-70, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23934272

RESUMO

BACKGROUND: We assessed the acute impact of laparoscopic Roux-en-Y gastric bypass (GBP) or sleeve gastrectomy (SG) compared to caloric-matched control group without surgery on glucose excursion in obese patients with type 2 diabetes, and examined if this was mediated by changes in insulin resistance, early insulin response or glucagon-like peptide (GLP)-1 levels. METHODS: Six-day subcutaneous continuous glucose monitoring (CGM) recordings were obtained from patients beginning 3 days before GBP (n = 11), SG (n = 10) or fasting in control group (n = 10). GLP-1, insulin and glucose were measured during 75 g oral glucose tolerance testing at the start and end of each CGM. RESULTS: Post-operative hyperglycaemia occurred after both surgeries in the first 6 h, with a more rapid decline in glycaemia after GBP (p < 0.001). Beyond 24 h post-operatively, continuous overlapping of net glycaemia action reduced from baseline after GBP (median [interquartile range]) 1.6 [1.2-2.4] to 1.0 [0.7-1.3] and after SG 1.4 [0.9-1.8] to 0.7 [0.7-1.0]; p < 0.05), similar to controls (2.2 [1.7-2.5] to 1.3 [0.8-2.8] p < 0.05). Higher log GLP-1 increment post-oral glucose occurred after GBP (mean ± SE, 0.80 ± 0.12 vs. 0.37 ± 0.09, p < 0.05), but not after SG or control intervention. Among subgroup with baseline hyperglycaemia, a reduction in HOMA-IR followed GBP. Reduction in time and level of peak glucose and 2-h glucose occurred after both surgeries but not in controls. CONCLUSIONS: GBP and SG have a similar acute impact on reducing glycaemia to caloric restriction; however, with a superior impact on glucose tolerance.


Assuntos
Cirurgia Bariátrica , Restrição Calórica , Diabetes Mellitus Tipo 2/cirurgia , Hiperglicemia/fisiopatologia , Obesidade Mórbida/cirurgia , Adulto , Glicemia/análise , Diabetes Mellitus Tipo 2/fisiopatologia , Feminino , Gastrectomia , Derivação Gástrica , Peptídeo 1 Semelhante ao Glucagon/sangue , Intolerância à Glucose/fisiopatologia , Teste de Tolerância a Glucose , Humanos , Hiperglicemia/cirurgia , Insulina/sangue , Resistência à Insulina/fisiologia , Laparoscopia , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/fisiopatologia
13.
Comput Methods Programs Biomed ; 109(2): 190-6, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22119761

RESUMO

Located between the left atrium and the left ventricle, the mitral valve controls flow between these two cardiac chambers. Mitral valve dysfunction is a major cause of cardiac dysfunction and its dynamics are little known. A simple non-linear rotational spring model is developed and implemented to capture the dynamics of the mitral valve. A measured pressure difference curve was used as the input into the model, which represents an applied torque to the anatomical valve chords. A range of mechanical model hysteresis states were investigated to find a model that best matches reported animal data of chord movement during a heartbeat. The study is limited by the use of one dataset found in the literature due to the highly invasive nature of getting this data. However, results clearly highlight fundamental physiological issues, such as the damping and chord stiffness changing within one cardiac cycle, that would be directly represented in any mitral valve model and affect behaviour in dysfunction. Very good correlation was achieved between modeled and experimental valve angle with 1-10% absolute error in the best case, indicating good promise for future simulation of cardiac valvular dysfunction, such as mitral regurgitation or stenosis. In particular, the model provides a pathway to capturing these dysfunctions in terms of modeled stiffness or elastance that can be directly related to anatomical, structural defects and dysfunction.


Assuntos
Valva Mitral/fisiologia , Modelos Anatômicos , Modelos Cardiovasculares , Algoritmos , Fenômenos Biomecânicos/fisiologia , Humanos
16.
Comput Methods Programs Biomed ; 101(2): 201-7, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20621383

RESUMO

The cardiac muscle activation or driver function, is a major determinant of cardiovascular dynamics, and is often approximated by the ratio of the left ventricle pressure to the left ventricle volume. In an intensive care unit, the left ventricle pressure is usually never measured, and the left ventricle volume is only measured occasionally by echocardiography, so is not available real-time. This paper develops a method for identifying the driver function based on correlates with geometrical features in the aortic pressure waveform. The method is included in an overall cardiovascular modelling approach, and is clinically validated on a porcine model of pulmonary embolism. For validation a comparison is done between the optimized parameters for a baseline model, which uses the direct measurements of the left ventricle pressure and volume, and the optimized parameters from the approximated driver function. The parameters do not significantly change between the two approaches thus showing that the patient specific approach to identifying the driver function is valid, and has potential clinically.


Assuntos
Cuidados de Enfermagem , Sistemas de Identificação de Pacientes , Humanos , Modelos Teóricos
17.
Math Biosci ; 227(1): 44-55, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20600161

RESUMO

In critical care tight control of blood glucose levels has been shown to lead to better clinical outcomes. The need to develop new protocols for tight glucose control, as well as the opportunity to optimize a variety of other drug therapies, has led to resurgence in model-based medical decision support in this area. One still valid hindrance to developing new model-based protocols using so-called virtual patients, retrospective clinical data, and Monte Carlo methods is the large amount of computational time and resources needed. This paper develops fast analytical-based methods for insulin-glucose system model that are generalizable to other similar systems. Exploiting the structure and partial solutions in a subset of the model is the key in finding accurate fast solutions to the full model. This approach successfully reduced computing time by factors of 5600-144000 depending on the numerical error management method, for large (50-164 patients) virtual trials and Monte Carlo analysis. It thus allows new model-based or model-derived protocols to be rapidly developed via extensive simulation. The new method is rigorously compared to existing standard numerical solutions and is found to be highly accurate to within 0.2%.


Assuntos
Glicemia/metabolismo , Transtornos do Metabolismo de Glucose/sangue , Transtornos do Metabolismo de Glucose/terapia , Modelos Biológicos , Algoritmos , Ensaios Clínicos como Assunto , Simulação por Computador , Tomada de Decisões Assistida por Computador , Humanos , Insulina/sangue , Insulina/uso terapêutico , Cinética , Método de Monte Carlo , Fatores de Tempo
18.
Comput Methods Programs Biomed ; 99(1): 75-87, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20097440

RESUMO

Lumped parameter approaches for modelling the cardiovascular system typically have many parameters of which a significant percentage are often not identifiable from limited data sets. Hence, significant parts of the model are required to be simulated with little overall effect on the accuracy of data fitting, as well as dramatically increasing the complexity of parameter identification. This separates sub-structures of more complex cardiovascular system models to create uniquely identifiable simplified models that are one to one with the measurements. In addition, a new concept of parameter identification is presented where the changes in the parameters are treated as an actuation force into a feed back control system, and the reference output is taken to be steady state values of measured volume and pressure. The major advantage of the method is that when it converges, it must be at the global minimum so that the solution that best fits the data is always found. By utilizing continuous information from the arterial/pulmonary pressure waveforms and the end-diastolic time, it is shown that potentially, the ventricle volume is not required in the data set, which was a requirement in earlier published work. The simplified models can also act as a bridge to identifying more sophisticated cardiac models, by providing an initial set of patient specific parameters that can reveal trends and interactions in the data over time. The goal is to apply the simplified models to retrospective data on groups of patients to help characterize population trends or un-modelled dynamics within known bounds. These trends can assist in improved prediction of patient responses to cardiac disturbance and therapy intervention with potentially smaller and less invasive data sets. In this way a more complex model that takes into account individual patient variation can be developed, and applied to the improvement of cardiovascular management in critical care.


Assuntos
Cuidados Críticos , Técnicas de Diagnóstico Cardiovascular , Sistema Cardiovascular , Simulação por Computador , Bases de Dados Factuais , Diagnóstico por Computador , Humanos
19.
Math Biosci ; 216(2): 132-9, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18817788

RESUMO

A previously validated cardiovascular system (CVS) model and parameter identification method for cardiac and circulatory disease states are extended and further validated in a porcine model (N=6) of induced endotoxic shock with hemofiltration. Errors for the identified model are within 10% when the model is re-simulated and compared to the clinical data. All identified parameter trends over time in the experiments match clinically expected changes both individually and over the cohort. This work represents a further clinical validation of these model-based cardiovascular diagnosis and therapy guidance methods for use with monitoring endotoxic disease states.


Assuntos
Modelos Cardiovasculares , Choque Séptico/diagnóstico , Animais , Simulação por Computador , Modelos Animais de Doenças , Hemodinâmica , Hemofiltração , Choque Séptico/fisiopatologia , Suínos
20.
Comput Methods Programs Biomed ; 91(2): 135-44, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18466998

RESUMO

A cardiovascular system (CVS) model has previously been validated in simulated cardiac and circulatory disease states. It has also been shown to accurately capture all main hemodynamic trends in a porcine model of pulmonary embolism. In this research, a slightly extended CVS model and parameter identification process are presented and validated in a porcine experiment of positive end-expiratory pressure (PEEP) titrations at different volemic levels. The model is extended to more physiologically represent the separation of venous and arterial circulation. Errors for the identified model are within 5% when re-simulated and compared to clinical data. All identified parameter trends match clinically expected changes. This work represents another clinical validation of the underlying fundamental CVS model, and the methods and approach of using them for cardiovascular diagnosis in critical care.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Circulação Coronária/fisiologia , Sistemas de Apoio a Decisões Clínicas , Coração/fisiologia , Hemodinâmica/fisiologia , Modelos Cardiovasculares , Respiração com Pressão Positiva/métodos , Algoritmos , Animais , Simulação por Computador , Humanos , Suínos , Volume de Ventilação Pulmonar/fisiologia