Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Rev. bras. pesqui. méd. biol ; Braz. j. med. biol. res;48(1): 46-50, 01/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-730439

RESUMO

In anurans, changes in ambient temperature influence body temperature and, therefore, energy consumption. These changes ultimately affect energy supply and, consequently, heart rate (HR). Typically, anurans living in different thermal environments have different thermal sensitivities, and these cannot be distinguished by changes in HR. We hypothesized that Rhinella jimi (a toad from a xeric environment that lives in a wide range of temperatures) would have a lower thermal sensitivity regarding cardiac control than R. icterica (originally from a tropical forest environment with a more restricted range of ambient temperatures). Thermal sensitivity was assessed by comparing animals housed at 15° and 25°C. Cardiac control was estimated by heart rate variability (HRV) and heart rate complexity (HRC). Differences in HRV between the two temperatures were not significant (P=0.214 for R. icterica and P=0.328 for R. jimi), whereas HRC differences were. All specimens but one R. jimi had a lower HRC at 15°C (all P<0.01). These results indicate that R. jimi has a lower thermal sensitivity and that cardiac control is not completely dependent on the thermal environment because HRC was not consistently different between temperatures in all R. jimi specimens. This result indicates a lack of evolutive trade-offs among temperatures given that heart rate control at 25°C is potentially not a constraint to heart rate control at 15°C.

2.
Braz J Med Biol Res ; 48(1): 46-50, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25493382

RESUMO

In anurans, changes in ambient temperature influence body temperature and, therefore, energy consumption. These changes ultimately affect energy supply and, consequently, heart rate (HR). Typically, anurans living in different thermal environments have different thermal sensitivities, and these cannot be distinguished by changes in HR. We hypothesized that Rhinella jimi (a toad from a xeric environment that lives in a wide range of temperatures) would have a lower thermal sensitivity regarding cardiac control than R. icterica (originally from a tropical forest environment with a more restricted range of ambient temperatures). Thermal sensitivity was assessed by comparing animals housed at 15° and 25°C. Cardiac control was estimated by heart rate variability (HRV) and heart rate complexity (HRC). Differences in HRV between the two temperatures were not significant (P=0.214 for R. icterica and P=0.328 for R. jimi), whereas HRC differences were. All specimens but one R. jimi had a lower HRC at 15°C (all P<0.01). These results indicate that R. jimi has a lower thermal sensitivity and that cardiac control is not completely dependent on the thermal environment because HRC was not consistently different between temperatures in all R. jimi specimens. This result indicates a lack of evolutive trade-offs among temperatures given that heart rate control at 25°C is potentially not a constraint to heart rate control at 15°C.

3.
IEEE Trans Neural Netw ; 14(6): 1572-5, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-18244603

RESUMO

We analytically investigate the existence of global and partial synchronism in neural networks where each node is represented by a phase oscillator. Partial synchronism, which is important to pattern recognition, can be caused by increasing the natural frequency of an oscillator and restricting the frequencies of others in certain ranges.

4.
Biosci Rep ; 21(2): 181-8, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11725866

RESUMO

The article discusses the importance of avian skeletal muscle as a source for heat generation by means of both shivering and non-shivering. Non-shivering thermogenesis in birds is still a polemic issue. Recent evidence at the molecular/cellular level indicates, however, that this type of heat generation may also exist among birds. The involvement of the sarcoplasmic reticulum calcium ATPase in non-shivering thermogenesis is discussed in-depth.


Assuntos
Aves/fisiologia , Músculo Esquelético/fisiologia , Termogênese/fisiologia , Animais , ATPases Transportadoras de Cálcio/metabolismo , Retículo Sarcoplasmático/enzimologia , ATPases Transportadoras de Cálcio do Retículo Sarcoplasmático
5.
Respir Physiol ; 128(2): 229-33, 2001 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11812387

RESUMO

The gas gill of diving insects allows gas exchange with the surrounding water, thus extending diving time. Incompressible gas gills can potentially last indefinitely underwater, but compressible gas gills have a definite lifetime. Theoretical models of a dive event have reached opposite conclusions about the oxygen gain (G, the ratio between the duration of the diving event and the time that the initial oxygen content of the bubble would allow the insect to stay underwater). While some authors claim that G has a fixed value independently of the parameters of the dive (e.g. oxygen consumption rate) others claim the contrary. However, these claims are based on numerical solutions of the models. In this study we offer an analytical solution to the problem. The analysis of a model with constant area for gas exchange demonstrates that G cannot have a fixed value, for a fixed gain would imply in a P(O(2)) inside the bubble different from the one occurring as a result of physical constraints of the gas exchange process.


Assuntos
Mergulho/fisiologia , Brânquias/metabolismo , Insetos/fisiologia , Consumo de Oxigênio/fisiologia , Algoritmos , Animais , Cinética , Modelos Biológicos , Nitrogênio/metabolismo , Temperatura
6.
Braz J Med Biol Res ; 33(8): 937-47, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10920436

RESUMO

The use of limiting dilution assay (LDA) for assessing the frequency of responders in a cell population is a method extensively used by immunologists. A series of studies addressing the statistical method of choice in an LDA have been published. However, none of these studies has addressed the point of how many wells should be employed in a given assay. The objective of this study was to demonstrate how a researcher can predict the number of wells that should be employed in order to obtain results with a given accuracy, and, therefore, to help in choosing a better experimental design to fulfill one's expectations. We present the rationale underlying the expected relative error computation based on simple binomial distributions. A series of simulated in machina experiments were performed to test the validity of the a priori computation of expected errors, thus confirming the predictions. The step-by-step procedure of the relative error estimation is given. We also discuss the constraints under which an LDA must be performed.


Assuntos
Técnicas de Diluição do Indicador , Computação Matemática , Distribuição Binomial , Contagem de Células/instrumentação , Contagem de Células/métodos , Técnicas de Diluição do Indicador/instrumentação , Modelos Imunológicos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Projetos de Pesquisa , Tamanho da Amostra
7.
Braz J Med Biol Res ; 33(8): 967-82, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10920440

RESUMO

A system is said to be "instantaneous" when for a given constant input an equilibrium output is obtained after a while. In the meantime, the output is changing from its initial value towards the equilibrium one. This is the transient period of the system and transients are important features of open-respirometry systems. During transients, one cannot compute the input amplitude directly from the output. The existing models (e.g., first or second order dynamics) cannot account for many of the features observed in real open-respirometry systems, such as time lag. Also, these models do not explain what should be expected when a system is speeded up or slowed down. The purpose of the present study was to develop a mechanistic approach to the dynamics of open-respirometry systems, employing basic thermodynamic concepts. It is demonstrated that all the main relevant features of the output dynamics are due to and can be adequately explained by a distribution of apparent velocities within the set of molecules travelling along the system. The importance of the rate at which the molecules leave the sensor is explored for the first time. The study approaches the difference in calibrating a system with a continuous input and with a "unit impulse": the former truly reveals the dynamics of the system while the latter represents the first derivative (in time) of the former and, thus, cannot adequately be employed in the apparent time-constant determination. Also, we demonstrate why the apparent order of the output changes with volume or flow.


Assuntos
Modelos Biológicos , Mecânica Respiratória/fisiologia , Termodinâmica , Espirometria
8.
Rev. bras. pesqui. méd. biol ; Braz. j. med. biol. res;33(8): 937-47, Aug. 2000. tab, graf
Artigo em Inglês | LILACS | ID: lil-265851

RESUMO

The use of limiting dilution assay (LDA) for assessing the frequency of responders in a cell population is a method extensively used by immunologists. A series of studies addressing the statistical method of choice in an LDA have been published. However, none of these studies has addressed the point of how many wells should be employed in a given assay. The objective of this study was to demonstrate how a researcher can predict the number of wells that should be employed in order to obtain results with a given accuracy, and, therefore, to help in choosing a better experimental design to fulfill one's expectations. We present the rationale underlying the expected relative error computation based on simple binomial distributions. A series of simulated in machina experiments were performed to test the validity of the a priori computation of expected errors, thus confirming the predictions. The step-by-step procedure of the relative error estimation is given. We also discuss the constraints under which an LDA must be performed


Assuntos
Técnicas de Diluição do Indicador , Computação Matemática , Distribuição Binomial , Contagem de Células/instrumentação , Contagem de Células/métodos , Modelos Imunológicos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
9.
Rev. bras. pesqui. méd. biol ; Braz. j. med. biol. res;33(8): 967-82, Aug. 2000. graf
Artigo em Inglês | LILACS | ID: lil-265855

RESUMO

A system is said to be "instantaneous" when for a given constant input an equilibrium output is obtained after a while. In the meantime, the output is changing from its initial value towards the equilibrium one. This is the transient period of the system and transients are important features of open-respirometry systems. During transients, one cannot compute the input amplitude directly from the output. The existing models (e.g., first or second order dynamics) cannot account for many of the features observed in real open-respirometry systems, such as time lag. Also, these models do not explain what should be expected when a system is speeded up or slowed down. The purpose of the present study was to develop a mechanistic approach to the dynamics of open-respirometry systems, employing basic thermodynamic concepts. It is demonstrated that all the main relevant features of the output dynamics are due to and can be adequately explained by a distribution of apparent velocities within the set of molecules travelling along the system. The importance of the rate at which the molecules leave the sensor is explored for the first time. The study approaches the difference in calibrating a system with a continuous input and with a "unit impulse": the former truly reveals the dynamics of the system while the latter represents the first derivative (in time) of the former and, thus, cannot adequately be employed in the apparent time-constant determination. Also, we demonstrate why the apparent order of the output changes with volume or flow


Assuntos
Modelos Teóricos , Mecânica Respiratória/fisiologia , Termodinâmica , Espirometria
10.
Respir Physiol ; 113(3): 259-70, 1998 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9840335

RESUMO

Total-body plethysmography is a technique often employed in comparative physiology studies because it avoids excessive handling of the animals. The pressure signal obtained is generated by an increase in internal energy of the gas phase of the system. Currently, this increase in internal energy is ascribed to heating (and water vapour saturation) of the inspired gas. The standard equation for computing tidal-volume implies that only temperature and saturation differences can be responsible for generating the ventilation signal. In this study, we were able to demonstrate that the difference between the external process of the thoracic expansion, which is adiabatic, and the internal process of it, which is isothermic, is an important factor of internal energy change in the total-body plethysmography method. In other words, organic tissues transfer heat to the entering gas but also to the present gas, in a way that keeps internal expansion an isothermic process. This extra amount of energy was never taken into account before. Therefore, experiments using such a technique to measure tidal-volume should be done using isothermic chambers. Moreover, due to uncertainties of the complementary measurements (ambient and lung temperatures, ambient water vapour saturation) needed to compute tidal-volume using total-body plethysmography, a minimal temperature difference about 15 degrees C between body and ambient should exist to keep uncertainties in tidal-volume values below 5%. However, this limit is not absolute, because it varies as a function of humidity and degree of uncertainty of the complementary measurements.


Assuntos
Pletismografia Total/instrumentação , Algoritmos , Animais , Metabolismo Energético/fisiologia , Camundongos , Pletismografia Total/estatística & dados numéricos , Processamento de Sinais Assistido por Computador , Tórax/anatomia & histologia , Tórax/fisiologia , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA