Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Mater ; : e2310701, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38733269

RESUMO

Magnetic navigation systems are used to precisely manipulate magnetically responsive materials enabling the realization of new minimally invasive procedures using magnetic medical devices. Their widespread applicability has been constrained by high infrastructure demands and costs. The study reports on a portable electromagnetic navigation system, the Navion, which is capable of generating a large magnetic field over a large workspace. The system is easy to install in hospital operating rooms and transportable through health care facilities, aiding in the widespread adoption of magnetically responsive medical devices. First, the design and implementation approach for the system are introduced and its performance is characterized. Next, in vitro navigation of different microrobot structures is demonstrated using magnetic field gradients and rotating magnetic fields. Spherical permanent magnets, electroplated cylindrical microrobots, microparticle swarms, and magnetic composite bacteria-inspired helical structures are investigated. The navigation of magnetic catheters is also demonstrated in two challenging endovascular tasks: 1) an angiography procedure and 2) deep navigation within the circle of Willis. Catheter navigation is demonstrated in a porcine model in vivo to perform an angiography under magnetic guidance.

2.
Adv Sci (Weinh) ; 11(12): e2305537, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38225742

RESUMO

In minimally invasive surgery, such as cardiac ablation, magnetically steered catheters made of variable-stiffness materials can enable higher dexterity and higher force application to human tissue. However, the long transition time between soft and rigid states leads to a significant increase in procedure duration. Here, a fast-response, multisegmented catheter is described for minimally invasive surgery made of variable-stiffness thread (FRVST) that encapsulates a helical cooling channel. The rapid stiffness change in the FRVST, composed of a nontoxic shape memory polymer, is achieved by an active cooling system that pumps water through the helical channel. The FRVST displays a 66 times stiffness change and a 26 times transition enhancement compare with the noncooled version. The catheter allows for selective bending of each segment up to 127° in air and up to 76° in water under an 80 mT external magnetic field. The inner working channel can be used for cooling an ablation tip during a procedure and for information exchange via the deployment of wires or surgical tools.


Assuntos
Catéteres , Procedimentos Cirúrgicos Minimamente Invasivos , Humanos , Fenômenos Mecânicos , Água , Fenômenos Magnéticos
3.
Semin Neurol ; 43(3): 432-438, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37562456

RESUMO

Advances in robotic technology have improved standard techniques in numerous surgical and endovascular specialties, offering more precision, control, and better patient outcomes. Robotic-assisted interventional neuroradiology is an emerging field at the intersection of interventional neuroradiology and biomedical robotics. Endovascular robotics can automate maneuvers to reduce procedure times and increase its safety, reduce occupational hazards associated with ionizing radiations, and expand networks of care to reduce gaps in geographic access to neurointerventions. To date, many robotic neurointerventional procedures have been successfully performed, including cerebral angiography, intracranial aneurysm embolization, carotid stenting, and epistaxis embolization. This review aims to provide a survey of the state of the art in robotic-assisted interventional neuroradiology, consider their technical and adoption limitations, and explore future developments critical for the widespread adoption of robotic-assisted neurointerventions.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano , Robótica , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Procedimentos Endovasculares/métodos
4.
Adv Sci (Weinh) ; 9(1): e2103277, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34723442

RESUMO

Variable stiffness catheters are typically composed of an encapsulated core. The core is usually composed of a low melting point alloy (LMPA) or a thermoplastic polymer (TP). In both cases, there is a need to encapsulate the core with an elastic material. This imposes a limit to the volume of variable stiffness (VS) material and limits miniaturization. This paper proposes a new approach that relies on the use of thermosetting materials. The variable stiffness catheter (VSC) proposed in this work eliminates the necessity for an encapsulation layer and is made of a unique biocompatible thermoset polymer with an embedded heating system. This significantly reduces the final diameter, improves manufacturability, and increases safety in the event of complications. The device can be scaled to sub-millimeter dimensions, while maintaining a high stiffness change. In addition, integration into a magnetic actuation system allows for precise actuation of one or multiple tools.


Assuntos
Catéteres , Desenho de Equipamento/métodos , Robótica/métodos , Materiais Inteligentes/química , Humanos
5.
Adv Sci (Weinh) ; 8(18): e2101290, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34272935

RESUMO

Minimally invasive robotic surgery often requires functional tools that can change their compliance to adapt to the environment and surgical needs. This paper proposes a submillimeter continuous variable stiffness catheter equipped with a phase-change alloy that has a high stiffness variation in its different states, allowing for rapid compliance control. Variable stiffness is achieved through a variable phase boundary in the alloy due to a controlled radial temperature gradient. This catheter can be safely navigated in its soft state and rigidified to the required stiffness during operation to apply a desired force at the tip. The maximal contact force that the catheter applies to tissue can be continuously modified by a factor of 400 (≈20 mN-8 N). The catheter is equipped with a magnet and a micro-gripper to perform a fully robotic ophthalmic minimally invasive surgery on an eye phantom by means of an electromagnetic navigation system.


Assuntos
Catéteres , Desenho de Equipamento/métodos , Fenômenos Mecânicos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Oftalmológicos/instrumentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Ligas , Fenômenos Eletromagnéticos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Imagens de Fantasmas , Procedimentos Cirúrgicos Robóticos/métodos
6.
Adv Sci (Weinh) ; 8(1): 2000726, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33437567

RESUMO

Patients suffering from heart failure often require circulatory support using ventricular assist devices (VADs). However, most existing VADs provide nonpulsatile flow, involve direct contact between the blood flow and the device's lumen and moving components, and require a driveline to connect to an external power source. These design features often lead to complications such as gastrointestinal bleeding, device thrombosis, and driveline infections. Here, a concept of magnetically active cardiac patches (MACPs) that can potentially function as non-blood contacting, untethered pulsatile VADs inside a magnetic actuationsystem is reported. The MACPs, which are composed of permanent magnets and 3D-printed patches, are attached to the epicardial surfaces, thus avoiding direct contact with the blood flow. They provide powerful actuation assisting native heart pumping inside a magnetic actuation system. In ex vivo experiments on a healthy pig's heart, it is shown that the ventricular ejection fractions are as high as 37% in the left ventricle and 63% in the right ventricle. Non-blood contacting, untethered VADs can eliminate the risk of serious complications associated with existing devices, and provide an alternative solution for myocardial training and therapy for patients with heart failure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...