Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Sci Rep ; 10(1): 9906, 2020 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-32555300

RESUMO

Transcatheter aortic valve implantation (TAVI) still presents complications: paravalvular leakage (PVL) and onset of conduction abnormalities leading to permanent pacemaker implantation. Our aim was testing a validated patient-specific computational framework for prediction of TAVI outcomes and possible complications. Twenty-eight TAVI patients (14 SapienXT and 14 CoreValve) were retrospectively selected. Pre-procedural CT images were post-processed to create 3D patient-specific implantation sites. The procedures were simulated with finite element analysis. Simulations' results were compared against post-procedural clinical fluoroscopy and echocardiography images. The computational model was in good agreement with clinical findings: the overall stent diameter difference was 2.6% and PVL was correctly identified with a post-processing algorithm in 83% of cases. Strains in the implantation site were studied to assess the risk of conduction system disturbance and were found highest in the patient who required pacemaker implantation. This study suggests that computational tool could support safe planning and broadening of TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Simulação por Computador , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Valva Aórtica/diagnóstico por imagem , Valvuloplastia com Balão , Ecocardiografia , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Complicações Pós-Operatórias , Desenho de Prótese , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
J Am Soc Echocardiogr ; 33(5): 622-630, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32122741

RESUMO

OBJECTIVE: We aimed to assess the change in global and regional myocardial function before and after surgical revascularization and their added value when compared with conventional measures in children with anomalous left coronary artery from the pulmonary artery (ALCAPA). METHODS: Advanced echocardiographic assessment was performed pre- and postoperatively in 22 children with ALCAPA (eight male; median surgery age, 0.4 years; interquartile range, 0.21-1.05) and 22 healthy controls. Measurements included global and segmental longitudinal, radial, and circumferential two-dimensional speckle-tracking strain and postsystolic index. RESULTS: Global strains were lower in preoperative patients than in controls (longitudinal: -9% vs -21%; P < .001; circumferential: -11% vs -21%; P < .001; radial: 18% vs 60%; P < .001) and improved postoperatively when compared with preoperative findings (longitudinal: -9% pre vs -16% post; P = .002, circumferential:-11% pre vs -17% post; P = .012, radial: 18% pre vs 53% post; P = .001). Preoperatively, patients with normal global systolic function on conventional echocardiography had significantly impaired global longitudinal and radial strain compared with healthy controls. Global mechanical dyssynchrony improved significantly postoperatively (longitudinal postsystolic index 43 pre vs 6 post, P < .001; circumferential 15 pre vs 2 post, P = .001; radial 48 pre vs 5 post, P = .003). Despite overall improvement in most segments, global longitudinal and circumferential and segmental peak strain in some of the segments supplied by the ALCAPA remained postoperatively abnormal. CONCLUSIONS: This study shows that myocardial deformation indices were a more sensitive measure of LV dysfunction in patients before and after ALCAPA repair than conventional echocardiographic measures. We believe, therefore, they should be added to routine preoperative and serial postoperative follow-up assessment.


Assuntos
Síndrome de Bland-White-Garland , Disfunção Ventricular Esquerda , Criança , Ecocardiografia , Humanos , Lactente , Masculino , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia
3.
Int J Cardiol ; 272: 64-69, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30153993

RESUMO

BACKGROUND: Measures of left ventricular (LV) systolic and diastolic function are known predictors of mortality after repair of tetralogy of Fallot. We aimed to characterise LV reverse remodelling achievable with ramipril therapy. METHODS AND RESULTS: A blinded post-hoc analysis of baseline and 6-month follow-up echocardiograms from the APPROPRIATE (ISRCTN: 97515585) randomised double-blinded placebo-controlled trial of ramipril therapy was performed in 64 patients: 32 in ramipril and 32 in placebo group. Tissue Doppler systolic and diastolic myocardial velocities, mitral inflow velocities and time intervals were measured. Left atrial area and left atrial emptying fraction were calculated. There was significant increase in long axis shortening mean (standard deviation); MAPSE [1.9 (4.2) mm vs -0.2 (3.7) mm; p = 0.030], peak lateral systolic velocity; S' lateral [1.0 (2.0) cm/s vs -0.3 (2.2) cm/s; p = 0.025], peak lateral early diastolic velocity; E' lateral [0.57 (2.4) cm/s vs -3.3 (3.9) cm/s; p < 0.001], transmitral to lateral mitral annular early diastolic velocity ratio; E/E' lateral [-0.7 (1.9) vs 1.5 (1.9); p < 0.001] over the study period in the ramipril compared to the placebo group. Significantly higher measurements were observed in the ramipril arm of the subgroup of patients with right ventricular restrictive physiology in terms of peak late diastolic velocity; A [5.9 (13.5) cm/s vs -5.8 (12.5) cm/s; p = 0.041] and early to late diastolic transmitral velocity ratio; E/A [-0.18 (0.42) vs 0.23 (0.48); p = 0.037]. CONCLUSION: Six months' ramipril treatment appears to limit progression of both diastolic and systolic LV function in adults late after tetralogy of Fallot repair. With increased appreciation that even subtle LV disease predicts tetralogy of Fallot outcomes, further clinical trials of drug therapies are justified.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Complicações Pós-Operatórias/tratamento farmacológico , Insuficiência da Valva Pulmonar/tratamento farmacológico , Ramipril/uso terapêutico , Tetralogia de Fallot/tratamento farmacológico , Função Ventricular Esquerda/efeitos dos fármacos , Adulto , Inibidores da Enzima Conversora de Angiotensina/farmacologia , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/epidemiologia , Ramipril/farmacologia , Método Simples-Cego , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/prevenção & controle , Função Ventricular Esquerda/fisiologia , Adulto Jovem
4.
J Cardiovasc Magn Reson ; 20(1): 24, 2018 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-29609642

RESUMO

BACKGROUND: Children with chronic kidney disease (CKD) have increased cardiovascular mortality. Identifying high-risk children who may benefit from further therapeutic intervention is difficult as cardiovascular abnormalities are subtle. Although transthoracic echocardiography may be used to detect sub-clinical abnormalities, it has well-known problems with reproducibility that limit its ability to accurately detect these changes. Cardiovascular magnetic resonance (CMR) is the reference standard method for assessing blood flow, cardiac structure and function. Furthermore, recent innovations enable the assessment of radial and longitudinal myocardial velocity, such that detection of sub-clinical changes is now possible. Thus, CMR may be ideal for cardiovascular assessment in pediatric CKD. This study aims to comprehensively assess cardiovascular function in pediatric CKD using CMR and determine its relationship with CKD severity. METHODS: A total of 120 children (40 mild, 40 moderate, 20 severe pre-dialysis CKD subjects and 20 healthy controls) underwent CMR with non-invasive blood pressure (BP) measurements. Cardiovascular parameters measured included systemic vascular resistance (SVR), total arterial compliance (TAC), left ventricular (LV) structure, ejection fraction (EF), cardiac timings, radial and longitudinal systolic and diastolic myocardial velocities. Between group comparisons and regression modelling were used to identify abnormalities in CKD and determine the effects of renal severity on myocardial function. RESULTS: The elevation in mean BP in CKD was accompanied by significantly increased afterload (SVR), without evidence of arterial stiffness (TAC) or increased fluid overload. Left ventricular volumes and global function were not abnormal in CKD. However, there was evidence of LV remodelling, prolongation of isovolumic relaxation time and reduced systolic and diastolic myocardial velocities. CONCLUSION: Abnormal cardiovascular function is evident in pre-dialysis pediatric CKD. Novel CMR biomarkers may be useful for the detection of subtle abnormalities in this population. Further studies are needed to determine to prognostic value of these biomarkers.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Doenças Cardiovasculares/diagnóstico por imagem , Coração/diagnóstico por imagem , Insuficiência Renal Crônica/complicações , Adolescente , Fatores Etários , Vasos Sanguíneos/fisiopatologia , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/fisiopatologia , Estudos de Casos e Controles , Criança , Feminino , Taxa de Filtração Glomerular , Coração/fisiopatologia , Hemodinâmica , Humanos , Rim/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Contração Miocárdica , Fenótipo , Valor Preditivo dos Testes , Prognóstico , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/fisiopatologia , Fatores de Risco , Índice de Gravidade de Doença , Função Ventricular Esquerda , Remodelação Ventricular
5.
J Biomech ; 71: 236-244, 2018 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-29482928

RESUMO

Patient-specific computational models are an established tool to support device development and test under clinically relevant boundary conditions. Potentially, such models could be used to aid the clinical decision-making process for percutaneous valve selection; however, their adoption in clinical practice is still limited to individual cases. To be fully informative, they should include patient-specific data on both anatomy and mechanics of the implantation site. In this work, fourteen patient-specific computational models for transcatheter aortic valve replacement (TAVR) with balloon-expandable Sapien XT devices were retrospectively developed to tune the material parameters of the implantation site mechanical model for the average TAVR population. Pre-procedural computed tomography (CT) images were post-processed to create the 3D patient-specific anatomy of the implantation site. Balloon valvuloplasty and device deployment were simulated with finite element (FE) analysis. Valve leaflets and aortic root were modelled as linear elastic materials, while calcification as elastoplastic. Material properties were initially selected from literature; then, a statistical analysis was designed to investigate the effect of each implantation site material parameter on the implanted stent diameter and thus identify the combination of material parameters for TAVR patients. These numerical models were validated against clinical data. The comparison between stent diameters measured from post-procedural fluoroscopy images and final computational results showed a mean difference of 2.5 ±â€¯3.9%. Moreover, the numerical model detected the presence of paravalvular leakage (PVL) in 79% of cases, as assessed by post-TAVR echocardiographic examination. The final aim was to increase accuracy and reliability of such computational tools for prospective clinical applications.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Modelagem Computacional Específica para o Paciente , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/anatomia & histologia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Valvuloplastia com Balão , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Ecocardiografia , Feminino , Análise de Elementos Finitos , Fluoroscopia , Humanos , Masculino , Reprodutibilidade dos Testes , Stents , Tomografia Computadorizada por Raios X
6.
Heart ; 104(17): 1411-1416, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29288192

RESUMO

OBJECTIVES: Infants with symptomatic partial and transitional atrioventricular septal defect undergoing early surgical repair are thought to be at greater risk. However, the outcome and risk profile of this cohort of patients are poorly defined. The aim of this study was to investigate the outcome of symptomatic infants undergoing early repair and to identify risk factors which may predict mortality and reoperation. METHODS: This multicentre study recruited 51 patients (24 female) in three tertiary centres between 2000 and 2015. The inclusion criteria were as follows: (1) partial and transitional atrioventricular septal defect, (2) heart failure unresponsive to treatment, (3) biventricular repair during the first year of life. RESULTS: Median age at definitive surgery was 179 (range 0-357) days. Sixteen patients (31%) had unfavourable anatomy of the left atrioventricular valve: dysplastic (n=7), double orifice (n=3), severely deficient valve leaflets (n=1), hypoplastic left atrioventricular orifice and/or mural leaflet (n=3), short/poorly defined chords (n=2). There were three inhospital deaths (5.9%) after primary repair. Eleven patients (22%) were reoperated at a median interval of 40 days (4 days to 5.1 years) for severe left atrioventricular valve regurgitation and/or stenosis. One patient required mechanical replacement of the left atrioventricular valve. After median follow-up of 3.8 years (0.1-11.4 years), all patients were in New York Heart Association (NYHA) class I. In multivariable analysis, unfavourable anatomy of the left atrioventricular valve was the only risk factor associated with left atrioventricular valve reoperation. CONCLUSIONS: Although surgical repair is successful in the majority of the cases, patients with partial and transitional atrioventricular septal defect undergoing surgical repair during infancy experience significant morbidity and mortality. The reoperation rate is high with unfavourable left atrioventricular valve anatomy.


Assuntos
Procedimentos Cirúrgicos Cardiovasculares , Defeitos dos Septos Cardíacos/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias , Reoperação , Procedimentos Cirúrgicos Cardiovasculares/efeitos adversos , Procedimentos Cirúrgicos Cardiovasculares/métodos , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Defeitos dos Septos Cardíacos/diagnóstico , Defeitos dos Septos Cardíacos/mortalidade , Defeitos dos Septos Cardíacos/fisiopatologia , Humanos , Lactente , Masculino , Valva Mitral/anormalidades , Valva Mitral/fisiopatologia , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Reoperação/métodos , Reoperação/mortalidade , Fatores de Risco , Reino Unido
7.
J Interv Cardiol ; 29(3): 319-24, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27245126

RESUMO

OBJECTIVES: To assess the necessity for balloon aortic valvuloplasty (BAV) during transfemoral transcatheter aortic valve implantation (TAVI) when using balloon-expandable valves. BACKGROUND: BAV is a usual part of TAVI procedures, prior to valve implantation. However, the benefits and necessity of this are unknown and recent evidence in self-expanding valves suggests it may not be necessary. METHODS: Retrospective single-center study of 154 patients undergoing first-time, transfemoral TAVI for native aortic valve stenosis, with (N = 76), and without (N = 78), BAV as part of the procedure. Data collected included demographic, procedural, and outcome data. RESULTS: BAV did not alter VARC-2 defined procedural success or early safety compared to not performing a BAV, including mortality, degree of aortic regurgitation, or need for post-TAVI balloon dilatation, although there was a strong trend to reduced stroke when not performing a BAV. There was a significantly reduced procedural time (P = 0.01) and fluoroscopic time (P < 0.001) without performing a BAV. There were no differences in cerebral embolization (solid, gaseous, or total emboli) noted between the 2 groups, as measured on transcranial doppler (TCD). CONCLUSIONS: TAVI can be effectively and safely performed without a BAV and this results in reduced procedural and fluoroscopic times, although embolization to the brain is not reduced. There is a trend toward reduced stroke risk. (J Interven Cardiol 2016;29:319-324).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Cateterismo Cardíaco/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valvuloplastia com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Int J Cardiovasc Imaging ; 32(4): 593-601, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26608801

RESUMO

The aim of this cohort study was to evaluate the value of echocardiographic multilayer strain analysis in the identification of arrhythmogenic cardiomyopathy (AC) in its earliest stages in which sudden cardiac death can occurs. Twenty seven asymptomatic relatives of AC probands (mean age 39.6 ± 19.5 years, 37 % male) with a desmosomal pathogenic mutation but no additional criteria for AC (group II) were compared to age and sex-matched healthy controls (group I). In addition, 70 patients harboring a pathogenic desmosomal mutation with "definitive" diagnosis of AC (group IV), and 19 subjects with "borderline" diagnosis (group III) were also studied. A standard echocardiographic evaluation plus left (LV) and right ventricular global and regional transmural, endocardial, and epicardial longitudinal strain (LS) analysis, was performed. In group II, while LV ejection fraction, fractional shortening, and S' were not significantly reduced compared to controls, transmural global LS was significantly reduced to 19.3 ± 1.8 % in group II versus 20.9 ± 1.1 % in controls (p = 0.0003). Compared to controls, group II presented significant (p < 0.05) regional LS decrease in the basal infero-lateral, antero-lateral, latero-apical, infero-septal, and septo-apical segments. Moreover, LS of the latero-apical and the basal antero-lateral segments was significantly altered in the epicardium (p < 0.05) but not significantly in the endocardium. Global and regional LV LS analysis allows detection of AC in an early or non-diagnostic stage of the disease. Moreover, epicardial LS analysis allows the detection of abnormalities earlier than endocardial LS.


Assuntos
Arritmias Cardíacas/complicações , Cardiomiopatias/diagnóstico por imagem , Ecocardiografia Doppler , Pericárdio/diagnóstico por imagem , Função Ventricular Esquerda , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Cardiomiopatias/etiologia , Cardiomiopatias/fisiopatologia , Estudos de Casos e Controles , Diagnóstico Precoce , Feminino , Humanos , Londres , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Pericárdio/fisiopatologia , Valor Preditivo dos Testes , Estresse Mecânico , Volume Sistólico , Adulto Jovem
9.
Open Heart ; 2(1): e000188, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25628893

RESUMO

OBJECTIVE: Palliative care (PC) in heart failure (HF) is beneficial and recommended in international HF guidelines. However, there is a perception that PC is underutilised in HF in the UK. This exploratory study aims to investigate, from a PC perspective, this perceived underutilisation and identify problems with current practice that may impact on the provision of PC in HF throughout the UK. METHODS: A prospective survey was electronically sent to PC doctors and nurses via the UK Association for Palliative Medicine and adult PC teams listed in the UK Hospice directory. RESULTS: We received 499 responses (42%-PC consultants). Although PC provision for patients with HF was widespread, burden on PC services was low (47% received less than 10 referrals annually). While PC was acknowledged to have a role in end-stage HF, there were differing views about the optimal model of care. Levels of interdisciplinary collaboration (58%) and mutual education (36%) were low. There were frequent reports that end-of-life matters were not addressed by cardiology prior to PC referral. Moreover, 24% of respondents experienced difficulties with implantable cardioverter defibrillator deactivation. CONCLUSIONS: Low HF referrals despite widespread availability of PC services and insufficient efforts by cardiology to address PC issues may contribute to the perception that PC is underutilised in HF. The challenges facing PC and HF identified here need to be further investigated and addressed. These findings will hopefully promote awareness of PC issues in HF and encourage debate on how to improve PC support for this population.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...