Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Burns Fire Disasters ; 37(2): 112-117, 2024 Jun.
Artigo em Francês | MEDLINE | ID: mdl-38974788

RESUMO

The incidence of extubation failure varies between 2 and 25% depending on the studied population. Few studies have been conducted in burn victims. To determine the incidence, causes, risk factors and outcome of burned patients after a failed extubation, a retrospective single-center case-control study was conducted over a period of 3 years (January 2018-December 2021). All burned patients aged over 16, ventilated for at least 24 hours and having had at least one extubation attempt were included. Extubation failure was defined as the need for re-intubation within 48 hours. Eighty-eight patients had planned extubation. These patients were divided into 2 groups comparable in terms of age and sex. Failure group: including patients with failed extubation (N= 34) and a success group (N= 64) including patients who succeeded. The incidence of extubation failure was 36.6%. Hypophosphatemia, anemia <8g/dl, duration of mechanical ventilation of 8,5 days and abundant secretions during extubation were identified as risk factors for extubation failure (p<0.05). The main cause of failure was retention of secretion (50%). Extubation failure was associated with prolonged length of stay (34 vs. 19 days, P= 0.005), increased infectious complications (P=0.007) and mortality rate (79.4%, 1.5%, P<0.001).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...