Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
NMR Biomed ; 32(1): e4034, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30457179

RESUMO

Entheses are regions where tendons and ligaments attach to bone, and are the primary target in seronegative and other diseases of the musculoskeletal (MSK) system. MRI has been widely used for visualizing features of inflammatory and degenerative MSK disease; however, normal tendons and entheses have short transverse relaxation times (T2 ), and show little or no signal with conventional clinical MRI pulse sequences, making it difficult to investigate their MR properties. In this study we examined the normal MR morphology of the cadaveric Achilles tendon and enthesis at 3 T using novel three-dimensional ultrashort echo time (3D UTE) Cones sequences, and at 11.7 T using conventional MRI sequences. We also studied the MR properties of the Achilles tendon and enthesis including T2 *, T1 , and magnetization transfer ratio (MTR). In addition, MT modeling of macromolecular proton fractions was investigated using 3D UTE Cones sequences at 3 T. Indentation testing was performed to investigate the mechanical properties of the tendons and entheses, and this was followed by histological examination. In total five specimens (<50 years) were investigated. On average, tendons and entheses respectively had T2 * values of 0.93 ± 0.48 ms and 2.77 ± 0.79 ms, T1 values of 644 ± 22 ms and 780 ± 55 ms, MTRs of 0.373 ± 0.03 and 0.244 ± 0.009 with an MT power of 1000° and frequency offset of 2 kHz, and macromolecular proton fractions of 18.0 ± 2.2% and 13.9 ± 1.9%. Compared with the tendon, the enthesis generally had a longer T2 *, a longer T1 , a lower MTR, and a lower macromolecular proton fraction as well as both a higher Young's modulus and stiffness. Results from this study are likely to provide a useful baseline for identifying deviations from the normal in seronegative arthritis and other disease of the entheses.


Assuntos
Tendão do Calcâneo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Imageamento Tridimensional , Masculino , Fatores de Tempo
2.
Magn Reson Imaging ; 49: 4-9, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29309823

RESUMO

We present three-dimensional ultrashort echo time Cones (3D-UTE-Cones) imaging as well as quantification of T2* and magnetization transfer ratio (MTR) of Achilles tendon and its enthesis of healthy volunteers and patients with psoriatic arthritis (PsA) using a 3T scanner. Quantitative T2*, T2 and magnetization transfer ratio (MTR) measurements of Achilles tendon and its enthesis were performed on healthy volunteers (n=7) and PsA patients (n=9) with 3D-UTE-Cones and clinical sequences at 3T. T2* was measured via single-component fitting of UTE images from two interleaved dual echo 3D-UTE-Cones acquisitions. MTR was measured with a dual echo 3D-UTE-Cones-MT sequence. Clinical morphological imaging and quantification of T2 with a Carr-Purcell-Meiboom-Gill (CPMG) sequence and MTR with a gradient recalled echo (GRE) sequence were also performed on each subject. T2* and MTR were analyzed for the two groups and the significance was evaluated. The 3D-UTE-Cones sequence provided high resolution imaging of entheses and tendons. Cones-T2* and Cones-MTR values were significantly higher for the PsA patients. GRE-MTR values showed no significant differences between the groups. No reliable T2 measurement could be achieved with the CPMG sequence due to insufficient signal from entheses and tendons. The 3D-UTE-Cones sequences can be used for morphological and quantitative evaluation of entheses and tendons in PsA patients.


Assuntos
Tendão do Calcâneo/diagnóstico por imagem , Artrite Psoriásica/diagnóstico por imagem , Artrite Psoriásica/patologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Tendão do Calcâneo/patologia , Adulto , Feminino , Humanos , Masculino
3.
Magn Reson Med ; 77(6): 2136-2145, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27263994

RESUMO

PURPOSE: We present three-dimensional ultrashort echo time Cones (3D UTE Cones) techniques for quantification of total water T1 ( T1TW), bound water T1 ( T1BW), and pore water T1 ( T1PW) in vitro and in vivo using a 3 Tesla (T) scanner. METHODS: T1TW, T1BW, and T1PW were measured with three-dimensional (3D) Cones and adiabatic inversion recovery Cone (IR-Cone) sequences. Two-dimensional (2D) nonselective ultrashort echo time (UTE) techniques, including saturation recovery, variable repetition times (TRs), and inversion recovery (IR) preparation approaches were compared with 3D-Cones techniques on bovine cortical bone samples (n = 8). The 3D Cones sequences were used to measure T1TW, T1BW, and T1PW in the tibial midshaft of healthy volunteers (n = 8). RESULTS: Comparable T1 images were achieved for cortical bone between 3D Cones and 2D UTE techniques as well as those published in the literature. The 3D Cones sequences showed a mean T1TW of 208 ± 22 ms, a mean T1PW of 545 ± 28 ms, and a mean T1BW of 131 ± 12 ms for bovine cortical bone; and a mean T1TW of 246 ± 32 ms, a mean T1PW of 524 ± 46 ms, and a mean T1BW of 134 ± 11 ms for the tibial midshaft of healthy volunteers. CONCLUSIONS: The 3D Cones sequences can be used for fast volumetric assessment of bound and pore water T1 images in vitro and in vivo. Magn Reson Med 77:2136-2145, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Água Corporal/química , Água Corporal/diagnóstico por imagem , Fêmur/química , Fêmur/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Absorção Fisico-Química , Algoritmos , Animais , Bovinos , Aumento da Imagem/métodos , Técnicas In Vitro , Porosidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
4.
NMR Biomed ; 29(10): 1373-80, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27496335

RESUMO

We report the three-dimensional ultrashort-TE (3D UTE) and adiabatic inversion recovery UTE (IR-UTE) sequences employing a radial trajectory with conical view ordering for bi-component T2 * analysis of bound water (T2 *(BW) ) and pore water (T2 *(PW) ) in cortical bone. An interleaved dual-echo 3D UTE acquisition scheme was developed for fast bi-component analysis of bound and pore water in cortical bone. A 3D IR-UTE acquisition scheme employing multiple spokes per IR was developed for bound water imaging. Two-dimensional UTE (2D UTE) and IR-UTE sequences were employed for comparison. The sequences were applied to bovine bone samples (n = 6) and volunteers (n = 6) using a 3-T scanner. Bi-component fitting of 3D UTE images of bovine samples showed a mean T2 *(BW) of 0.26 ± 0.04 ms and T2 *(PW) of 4.16 ± 0.35 ms, with fractions of 21.5 ± 3.6% and 78.5 ± 3.6%, respectively. The 3D IR-UTE signal showed a single-component decay with a mean T2 *(BW) of 0.29 ± 0.05 ms, suggesting selective imaging of bound water. Similar results were achieved with the 2D UTE and IR-UTE sequences. Bi-component fitting of 3D UTE images of the tibial midshafts of healthy volunteers showed a mean T2 *(BW) of 0.32 ± 0.08 ms and T2 *(PW) of 5.78 ± 1.24 ms, with fractions of 34.2 ± 7.4% and 65.8 ± 7.4%, respectively. Single-component fitting of 3D IR-UTE images showed a mean T2 *(BW) of 0.35 ± 0.09 ms. The 3D UTE and 3D IR-UTE techniques allow fast volumetric mapping of bound and pore water in cortical bone. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Algoritmos , Água Corporal/diagnóstico por imagem , Osso e Ossos/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Adulto , Animais , Água Corporal/química , Osso e Ossos/química , Bovinos , Humanos , Aumento da Imagem/métodos , Técnicas In Vitro , Masculino , Porosidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...