Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Dent Sci ; 18(3): 1361-1367, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37404616

RESUMO

Background/purpose: Immediate implant placement (IIP) with and without immediate provisionalization (Ipro) may yield satisfactory results in appropriate indications and treatment, especially in the esthetic zone. The aim of this study was to compare implant stability, marginal bone loss (MBL), survival rates, and patient satisfaction between IIP with Ipro and IIP without Ipro. Materials and methods: Seventy patients, each with a failed maxillary anterior tooth, were randomly assigned to IIP with Ipro (Group A: n = 35) or IIP without Ipro (Group B: n = 35). Implant stability quotient (ISQ) and standardized periapical radiographs were performed at surgery and at 3, 6, 9, and 12 months postoperatively to investigate implant stability and MBL, respectively. Survival was assessed 1 year after surgery. Patient satisfaction was evaluated with a visual analogue scale (VAS). Results: Primary ISQ and MBL were not significantly different between groups A and B immediately after surgery (P > 0.05). Implant survival was 100% in both groups, and only one mechanical complication was observed. Patient satisfaction was good at definitive crown delivery and postoperatively 1-year in both groups. However, the immediate postoperative VAS score in Group A was significantly higher than that in Group B (P < 0.05). Conclusion: Group A revealed significantly higher secondary ISQ than Group B at postoperatively 3, 6, 9, and 12 months. There were no significant differences between groups A and B in terms of MBL and survival. Notably, patient satisfaction in Group A was significantly higher than in Group B immediately after surgery.

2.
J Dent Sci ; 18(3): 1272-1279, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37404618

RESUMO

Background/purpose: Implant stability is crucial for successful osseointegration. Marginal bone level is considered an important indicator of long-term implant success and stability. The purposes of this study were to investigate 1) the effect of age, gender, bone density, implant length, and implant diameter on insertion torque (IT), primary implant stability quotient (ISQ), and secondary ISQ, 2) the impact of age, gender, bone density, implant length, implant diameter, IT, and ISQ on marginal bone loss (MBL). Materials and methods: Ninety patients who needed implant therapy were enrolled and overall 156 implants were installed to support single crowns. IT and ISQ were recorded for all implants during surgery and ISQ measurements were performed at follow-up visits. Age, gender, bone density, implant length and diameter were also registered. Radiographic evaluation of MBL was performed postoperative immediate (baseline), 3, 6, 9, 12, 18, and 24 months using digital periapical radiographs. Results: Age had little effect on IT and primary ISQ (P > 0.05). Generally, males had higher IT and primary ISQ, but no significant differences between genders were detected. Bone density showed significant effects on IT and primary ISQ. Correlation analysis revealed high positive correlations between IT/bone density and primary ISQ/implant diameter. Significant impacts of bone density and IT on MBL were found. Conclusion: Implant diameter had a more profound impact than length on IT/primary ISQ. Bone density played a considerable role in IT/primary ISQ determination. Bone density and IT had more impacts than primary ISQ on MBL.

3.
Materials (Basel) ; 6(11): 5335-5351, 2013 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-28788393

RESUMO

In recent studies, sealing of exposed dentinal tubules is generally considered as one of the most effective strategies to treat dentin hypersensitivity. Mesoporous bioactive glass (MBG) is a potential material for treating dentin hypersensitivity due to its highly specific areas for dissolution and re-precipitated reaction for reduction in dentin permeability. The groups of commercial products of PerioGlas®, synthetic MBG and MBG without phosphorus (MBGNP) were compared. The MBG and MBGNP powders were prepared by the sol-gel method and mixed with different calculated ratios of phosphoric acid (PA) and then was brushed onto dentin surfaces. We used X-ray diffractometer (XRD), scanning electronic microscope (SEM), and Fourier transform infrared spectroscopy (FTIR) to investigate the physiochemistry and the occlusion ability of dentinal tubules. The results showed that MBG paste mixed with PA solution has a better ability for occluding dentinal tubules than MBGNP; it has a short reaction time and good operability. The major crystallite phase of MBG agents was monocalcium phosphate monohydrate [Ca(H2PO4)2·H2O] in the early stages of the reactions. MBG pastes that were mixed with 30% and 40% PA had the ability to create excellent penetration depth greater than 80 µm. These agents have the potential to treat dentin hypersensitivity.

4.
Angle Orthod ; 82(3): 565-71, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-21988519

RESUMO

Simultaneous impactions of first, second, and third permanent molars comprises a very rare clinical situation with diverse therapeutic approaches and is a difficult challenge for dentists. Early diagnosis and treatment of eruption disturbances contributes to optimal outcomes. This article reports the treatment of a teenager with severe impaction of right mandibular first, second, and third molars, which hinders the masticatory function and dental arch integrity. A decision-making process and a simple orthodontic technique are described. To shorten the treatment time and simplify the procedures, the impacted right mandibular third and second molars were orthodontically uprighted with an innovative tip-back cantilever. Subsequently, the deeply impacted right mandibular first molar was extracted with minimal obstacles. The combined surgical-orthodontic approach resolved a challenging clinical problem and eliminated the need for prosthetic or dental implant replacement of the impacted molars. Good occlusion, normal function, and a healthy periodontium of the patient were also achieved.


Assuntos
Dente Molar/patologia , Extrusão Ortodôntica , Dente Impactado/terapia , Adolescente , Cefalometria , Humanos , Masculino , Mandíbula , Dente Molar/cirurgia , Extração Dentária , Dente Impactado/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...