Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Stereotact Funct Neurosurg ; 85(4): 184-91, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17389818

RESUMO

PURPOSE: Volumetry is the most commonly used method to measure tumor response in patients who receive Gamma Knife radiosurgery. We calculated the data errors in measurement made by different methods based on the stereotactic fiducials (Gamma Knife workstation), surface area multiplied by thickness (PACS), and product of maximum diameter in x, y, and z dimensions (geometric method) to more precisely evaluate tumor response in patients treated with Gamma Knife radiosurgery. MATERIALS AND METHODS: From 2003 to 2006, 210 tumors were enrolled in this study. MRIs obtained from these patients were transferred to Gamma Knife and PACS workstations. Data errors were defined as the difference between the volume calculated by various methods and the Gamma Knife workstation divided by the volume obtained from the Gamma Knife workstation. Linear regression was used for data analysis. RESULTS: There were 27 lesions with volume <0.5 cm(3), 97 lesions between 0.5 and 4 cm(3), 68 lesions between 4 and 14 cm(3), and 18 lesions larger than 14 cm(3). A strong linear correlation was found between the volume measurement by Gamma Knife workstation and PACS and the geometric method (r = 0.993, 0.967, respectively). Poor correlation between the Gamma Knife and PACS workstation volume measurement was observed in tumors less than 0.5 cm(3) (r = 0.763), but better correlation was found between the Gamma Knife workstation and geometric method (r = 0.871). Fewer data errors were observed in the PACS than in the geometric method (p < 0.001) in tumors with volumes of 0.5-4 cm(3) and 4-14 cm(3); whereas in tumors less than 0.5 cm(3), fewer data errors were observed in the geometric method (p = 0.01). The data error in the whole series was 6 +/- 15% in the PACS system and was relatively correlated with the volume (p = 0.03) and the number of slices (p = 0.021), but not with the Pearsonian coefficient of skewness (p = 0.81). CONCLUSION: The different methods of measurement of tumor volume (>0.5 cm(3)) demonstrated strong linear correlation. In tumors with volume less than 0.5 cm(3), the most reliable method was the geometric method. When using the PACS system in the evaluation of tumor response, a data error as high as 21% should be considered.


Assuntos
Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Radiocirurgia/métodos , Radiocirurgia/estatística & dados numéricos , Carga Tumoral , Neoplasias Encefálicas/diagnóstico por imagem , Determinação de Ponto Final , Humanos , Modelos Lineares , Imageamento por Ressonância Magnética/estatística & dados numéricos , Neoplasia Residual , Valor Preditivo dos Testes , Radiografia , Reprodutibilidade dos Testes , Resultado do Tratamento
2.
J Clin Neurosci ; 12(7): 744-9, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16169730

RESUMO

OBJECTIVE: With the advent of interventional neuroradiology and stereotactic radiosurgery, dural arteriovenous fistulae are less often managed with open surgery. We evaluated the outcome of dural arteriovenous fistulae of the cavernous sinus treated with a combination of radiosurgery and embolization. MATERIAL AND METHODS: Twenty dural arteriovenous fistulae located in the cavernous sinus were enrolled in our study. Fifteen patients received X-knife radiosurgery alone and 5 also required embolization, one before radiosurgery and 4 after radiosurgery. The mean volume of the lesions was 2.8 ml (range 0.2-12.6), the corresponding radiation volume was 6.5 ml (range 0.6-24.6), and the conformity index was 2.9 (range 1.8-5.3). The mean peripheral and maximum radiation dose was 17.8 Gy (range 17-20) and 28.3 Gy (range 19-37) Gy, respectively. The clinical and imaging data were analyzed. RESULTS: The mean follow up period was 29 months (23-39). Seventy-five percent (15/20) of patients receiving radiosurgery alone achieved a symptomatic cure and with additional embolization 90% (18/20) were cured. All patients achieved cure on imaging after radiosurgery alone or in combination with embolization. Abnormal imaging findings were observed in two patients after treatment, one had an intracerebral hemorrhage and the other radiation edema, but both were asymptomatic. CONCLUSION: With multidisciplinary treatment with combined radiosurgery and embolization, satisfactory results can be achieved for dural arteriovenous fistulae with a low complication rate. In patients with mild symptoms, radiosurgery is the initial treatment option. Embolization should be performed in patients with severe symptoms or who have failed radiosurgery.


Assuntos
Seio Cavernoso/efeitos da radiação , Seio Cavernoso/cirurgia , Malformações Vasculares do Sistema Nervoso Central/terapia , Embolização Terapêutica , Radiocirurgia , Adulto , Idoso , Angiografia Cerebral/métodos , Seguimentos , Humanos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos , Técnicas Estereotáxicas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...