Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Oral Investig ; 20(7): 1515-24, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26507647

RESUMO

PURPOSE: Electrochemical oxidation following sandblasting and acid-etching (SLA) treatment has received interest as a surface modification procedure for titanium (Ti) implants (denoted as an SLAffinity surface); however, little information is available on its impacts on the in vivo performance of SLAffinity-Ti implants. The present study evaluated the osseointegration and biomechanical bone-tissue response to SLAffinity-Ti implants with micro- and nanoporous oxide layers. MATERIALS AND METHODS: The interaction between blood and the tested implants was examined. In total, 144 implants with the following surfaces were used: a standard machined (M-Ti), an SLA-Ti, and an SLAffinity-Ti surface. For each animal, four implants (one M-Ti, one SLA-Ti, and two SLAffinity-Ti) were inserted into the mandibular canine-premolar area for histomorphometric observations and another four implants were inserted into the flat surface on the anteromedial aspect of the rear tibia for removal torque (RT) tests. After 2, 4, and 8 weeks of implantation, histomorphometric and RT tests were conducted. RESULTS: Interactions between blood and implants were better for implants with the SLAffinity-Ti surface. RT tests showed a significant improvement in fixation strength for SLAffinity-Ti implants (84.5 ± 8.7 N-cm) after 8 weeks compared to M-Ti (62.95 ± 11.5 N-cm) and SLAffinity-Ti (76.1 ± 6.6 N-cm) implants. A histological evaluation showed that osseous integration had occurred with all implants after 8 weeks. SLAffinity-Ti implants exhibited 28.5 ± 6.2 % bone-to-implant contact (BIC) at 2 weeks and 84.3 ± 8.1 % at 8 weeks. M-Ti implants exhibited BIC levels of 17.0 ± 5.4 and 76.5 ± 6.3 %, whereas SLA-Ti implants exhibited BIC levels of 28.5 ± 6.2 and 81.1 ± 8.4 % at corresponding time intervals. In terms of the peri-implant bone area (BA), values for SLAffinity-Ti implants ranged from 29.5 ± 4.1 to 88.3 ± 3.0 %. For M-Ti implants, values ranged from 20.3 ± 5.5 to 81.7 ± 4.2 %. For SLA-Ti implants, values ranged from 23.0 ± 3.5 to 84.0 ± 3.6 %. CONCLUSIONS: Electrochemical oxidation increased the oxide layers and improved the blood interaction with SLAffinity-Ti implants, resulting in significantly higher bone apposition with the SLAffinity-Ti implants after 2 and 8 weeks of healing. An increase in resistance for the RT of SLAffinity-Ti implants over the 8-week healing period was also observed. CLINICAL RELEVANCE: The use of SLAffinity-Ti implants has potential for improvement of early osseointegration.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Osseointegração/fisiologia , Tíbia/cirurgia , Condicionamento Ácido do Dente , Animais , Polimento Dentário , Implantes Experimentais , Porosidade , Propriedades de Superfície , Suínos , Porco Miniatura , Titânio/química , Torque
2.
Med Eng Phys ; 35(12): 1825-30, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23764430

RESUMO

This study employed a noncontact resonance frequency (RF) detection technique that was developed by our group to evaluate the interfacial bone in in vitro implant-bone models. Based on our method, the implant-bone structure was excited by the acoustic energy of a loudspeaker, and its vibration response was acquired with a capacitance sensor. The spectral analysis was used to characterize the first RF value. Two types of in vitro defect models, Buccal-Lingual (BL) and Mesial-Distal (MD), were constructed for the verification. The measurements of the RF for a defect model clamped at four different heights (9, 10, 11, and 12 mm) were performed in two sensing directions (BL and MD). Moreover, each model was also analyzed using an Osstell Mentor. The obtained two parameters, RF and ISQ (Implant Stability Quotient), were statistically analyzed through one-way analysis of variance (ANOVA) and linear regression analysis for comparisons. The RF and the ISQ values obtained for all of the defect models at the four clamp heights decreased significantly (p < 0.05) with an increase in the severity of the defect. The two parameters for each imperfection increase significantly (p < 0.05) with an increase in the clamp height. Additionally, the RFs of all of the defect models are linearly correlated with their corresponding ISQs for the four clamp heights and the two measuring orientations. Therefore, our developed technique is feasible for the assessment of the postoperative healing around a dental implant.


Assuntos
Osso e Ossos/fisiologia , Implantes Dentários , Teste de Materiais/métodos , Osseointegração
3.
J Formos Med Assoc ; 110(6): 397-400, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21741008

RESUMO

BACKGROUND/PURPOSE: Isolation of teeth with rubber dams is an important procedure for infection control in dentistry, especially in endodontic treatment. This study surveyed the prevalence of rubber dam usage in nonsurgical root canal treatment (RCT) by dentists under the National Health Insurance system in Taiwan. METHODS: A total of 1,332 completed RCT cases were randomly selected from a large database from the Bureau of National Health Insurance in Taiwan in 2004. The radiographs and dental charts of the selected cases were evaluated for the prevalence of rubber dam usage in RCT. The frequencies of rubber dam usage for RCT by dentists were compared between hospitals and private dental clinics and among six different regions in Taiwan. RESULTS: The overall prevalence of rubber dam usage for RCT by dentists under the National Health Insurance system in Taiwan was 16.5%. The frequency of rubber dam usage for RCT by dentists in hospitals (32.8%) was significantly higher than that (10.3%) in private dental clinics (p < 0.0001). However, there was no significant difference in the frequency of rubber dam usage for RCT by dentists among six different geographic regions in Taiwan. CONCLUSION: The prevalence of rubber dam usage for RCT by dentists in Taiwan is relatively low. Because rubber dam isolation of an endodontically-treated tooth can provide better infection control, increase patient protection, and improve treatment efficiency, there is an urgent need to advise dentists in Taiwan to use rubber dams for every RCT case.


Assuntos
Unidade Hospitalar de Odontologia/estatística & dados numéricos , Controle de Infecções Dentárias/estatística & dados numéricos , Prática Privada/estatística & dados numéricos , Tratamento do Canal Radicular , Diques de Borracha , Doenças Dentárias/terapia , Cavidade Pulpar/diagnóstico por imagem , Unidade Hospitalar de Odontologia/normas , Humanos , Ortodontia Preventiva/estatística & dados numéricos , Padrões de Prática Odontológica/normas , Prevalência , Prática Privada/normas , Melhoria de Qualidade , Radiografia , Tratamento do Canal Radicular/instrumentação , Tratamento do Canal Radicular/estatística & dados numéricos , Diques de Borracha/estatística & dados numéricos , Taiwan/epidemiologia , Doenças Dentárias/diagnóstico , Doenças Dentárias/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...