1.
J Biophotonics ; 11(8): e201700364, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29770615

RESUMO

Quantitative phase imaging (QPI) has been investigated to retrieve optical phase information of an object and applied to biological microscopy and related medical studies. In recent examples, differential phase contrast (DPC) microscopy can recover phase image of thin sample under multi-axis intensity measurements in wide-field scheme. Unlike conventional DPC, based on theoretical approach under partially coherent condition, we propose a new method to achieve isotropic differential phase contrast (iDPC) with high accuracy and stability for phase recovery in simple and high-speed fashion. The iDPC is simply implemented with a partially coherent microscopy and a programmable thin-film transistor (TFT) shield to digitally modulate structured illumination patterns for QPI. In this article, simulation results show consistency of our theoretical approach for iDPC under partial coherence. In addition, we further demonstrate experiments of quantitative phase images of a standard micro-lens array, as well as label-free live human cell samples.


Assuntos
Microscopia de Contraste de Fase/métodos , Algoritmos , Animais , Linhagem Celular Tumoral , Processamento de Imagem Assistida por Computador , Lentes , Luz , Camundongos , Microscopia de Contraste de Fase/instrumentação
2.
Opt Lett ; 41(2): 344-7, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26766710

RESUMO

A wide-field multi-plane endoscopic system incorporating multiplexed volume holographic gratings and Talbot illumination to simultaneously acquire optically sectioned fluorescence images of tissue structures from different depths is presented. The proposed endoscopic system is configured such that multiple Talbot-illumination planes occur inside a volumetric sample and serve as the input focal planes for the subsequent multiplexed volume holographic imaging gratings. We describe the design, implementation, and experimental data demonstrating this endoscopic system's ability to obtain optically sectioned multi-plane fluorescent images of tissue samples in wide-field fashion without scanning in lateral and axial directions.


Assuntos
Endoscopia/métodos , Holografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagem Óptica/métodos , Fenômenos Ópticos
3.
Opt Lett ; 40(23): 5542-5, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26625046

RESUMO

A dual-plane in-line digital holographic imaging method incorporating volume holographic microscopy (VHM) is presented to reconstruct objects in a single shot while eliminating zero-order and twin-image diffracted waves. The proposed imaging method is configured such that information from different axial planes is acquired simultaneously using multiplexed volume holographic imaging gratings, as used in VHM, and recorded as in-line holograms where the corresponding reference beams are generated in the fashion of Gabor's in-line holography. Unlike conventional VHM, which can take axial intensity information only at focal depths, the proposed method digitally reconstructs objects at any axial position. Further, we demonstrate the proposed imaging technique's ability to effectively eliminate zero-order and twin images for single-shot three-dimensional object reconstruction.


Assuntos
Holografia/métodos , Microscopia/métodos , Processamento de Imagem Assistida por Computador , Poliestirenos
4.
Opt Express ; 23(6): 7075-84, 2015 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-25837052

RESUMO

Structured illumination microscopy has been widely used to reconstruct optically sectioned fluorescence images in wide-field fashion; however, it still requires axial scanning to obtain multiple depth information of a volumetric sample. In this paper, a new imaging scheme, called speckle-based volume holographic microscopy system, is presented. The proposed system incorporates volumetric speckle illumination and multiplexed volume holographic gratings to acquire multi-plane images with optical sectioning capability, without any axial scanning. We present the design, implementation, and experimental image data demonstrating the proposed system's ability to simultaneously obtain wide-field, optically sectioned, and multi-depth resolved images of fluorescently labeled microspheres and tissue structures.

5.
Opt Express ; 23(4): 4046-54, 2015 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-25836443

RESUMO

A three dimensional (3D) pupil is an optical element, most commonly implemented on a volume hologram, that processes the incident optical field on a 3D fashion. Here we analyze the diffraction properties of a 3D pupil with finite lateral aperture in the 4-f imaging system configuration, using the Wigner Distribution Function (WDF) formulation. Since 3D imaging pupil is finite in both lateral and longitudinal directions, the WDF of the volume holographic 4-f imager theoretically predicts distinct Bragg diffraction patterns in phase space. These result in asymmetric profiles of diffracted coherent point spread function between degenerate diffraction and Bragg diffraction, elucidating the fundamental performance of volume holographic imaging. Experimental measurements are also presented, confirming the theoretical predictions.


Assuntos
Holografia/instrumentação , Imageamento Tridimensional/instrumentação , Lentes , Refratometria/instrumentação , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Holografia/métodos , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Luz , Modelos Teóricos , Refratometria/métodos , Espalhamento de Radiação
6.
Laser Photon Rev ; 8(5): L71-L75, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25678936

RESUMO

Optical sectioning techniques offer the ability to acquire three-dimensional information from various organ tissues by discriminating between the desired in-focus and out-of-focus (background) signals. Alternative techniques to confocal, such as active structured illumination, exist for fast optically sectioned images, but they require individual axial planes to be imaged consecutively. In this article, an imaging technique (THIN), by utilizing active Talbot illumination in 3D and multiplexed holographic Bragg filters for depth discrimination, is demonstrated for imaging in vivo 3D biopsy without mechanical or optical axial scanning.

7.
Opt Lett ; 38(4): 477-9, 2013 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-23455108

RESUMO

We present a design of phase-contrast filters embedded in a three-dimensional pupil to form phase-coded volume holographic gratings (VHGs) for spatial-spectral imaging. The phase-coded VHG improves image contrast and results in strong filtering properties to acquire weak phase structures of an object. In addition, incorporated with in-plane angle multiplexing, the multiplexed phase-coded VHGs enable obtaining weak phase information from multiple depths of an object. We experimentally demonstrate the multiplexed phase-coded VHGs for spatial-spectral imaging to enhance unstained features of spatial-spectral images of human breast cancer cells.


Assuntos
Holografia/métodos , Neoplasias da Mama/patologia , Humanos , Imagem Molecular
8.
J Biomed Opt ; 17(10): 107003, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23047254

RESUMO

Diffuse reflectance spectroscopy has been applied to detect tissue absorption and scattering properties associated with dysplasia, which is a potential precursor of epithelial cancers. The ability of DRS techniques to detect dysplasia could be improved by enhancing the detection of optical properties of the thin epithelial layer where dysplasia occurs. We propose a beveled fiber bundle probe consisting of a source fiber and multiple detection fibers parallel to each other and oriented obliquely to the tissue surface and investigate the sensitivity of reflectance measured with the probe to optical properties of a two-layered normal oral mucosa model. A scalable Monte Carlo method is employed to speed up analyzing spatially resolved reflectance spectra. Results reveal that the oblique probe is more sensitive to epithelial scattering and less sensitive to both stromal absorption and scattering than conventional perpendicular fiber configuration. The clinical relevance of the enhanced sensitivity to epithelial scattering by the proposed probe is demonstrated by quantifying optical properties of the two-layered tissue model from simulated data. The average error of extracted epithelial scattering coefficient is 1.5% and 32% using the oblique and perpendicular probe, respectively. The errors in other optical properties are all below 10% using the oblique probe.


Assuntos
Epitélio/química , Modelos Biológicos , Análise Espectral/instrumentação , Análise Espectral/métodos , Absorção , Simulação por Computador , Hemoglobinas , Humanos , Método de Monte Carlo , Mucosa Bucal/química , Fibras Ópticas , Imagens de Fantasmas , Reprodutibilidade dos Testes , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS