Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Diagnostics (Basel) ; 13(5)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36900093

RESUMO

Purpose: This study aimed to investigate the correlation between sonographic features and central neck lymph node metastasis (CNLM) in solitary solid papillary thyroid microcarcinoma (PTMC) with a taller-than-wide shape. Methods: A total of 103 patients with solitary solid PTMC with a taller-than-wide shape on ultrasonography who underwent surgical histopathological examination were retrospectively selected. Based on the presence or absence of CNLM, patients with PTMC were divided into a CNLM (n = 45) or nonmetastatic (n = 58) group, respectively. Clinical findings and ultrasonographic features, including a suspicious thyroid capsule involvement sign (STCS, which is defined as PTMC abutment or a disrupted thyroid capsule), were compared between the two groups. Additionally, postoperative ultrasonography was performed to assess patients during the follow-up period. Results: Significant differences were observed in sex and the presence of STCS between the two groups (p < 0.05). The specificity and accuracy of the male sex for predicting CNLM were 86.21% (50/58 patients) and 64.08% (66/103 patients), respectively. The sensitivity, specificity, positive predictive value (PPV), and accuracy of STCS for predicting CNLM were 82.22% (37/45 patients), 70.69% (41/58 patients), 68.52% (37/54 patients), and 75.73% (78/103 patients), respectively. The specificity, PPV, and accuracy of the combination of sex and STCS for predicting CNLM were 96.55% (56/58 patients), 87.50% (14/16 patients), and 67.96% (70/103 patients), respectively. A total of 89 (86.4%) patients were followed up for a median of 4.6 years, with no patient having recurrence as detected on ultrasonography and pathological examination. Conclusions: STCS is a useful ultrasonographic feature for predicting CNLM in patients with solitary solid PTMC with a taller-than-wide shape, especially in male patients. Solitary solid PTMC with a taller-than-wide shape may have a good prognosis.

2.
Diagnostics (Basel) ; 13(3)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36766650

RESUMO

OBJECTIVE: To evaluate the stiffness of the sciatic nerve by shear wave elastography (SWE) and to determine whether SWE can be used to predict diabetic foot ulcer (DFU) in a patient with diabetic peripheral neuropathy (DPN). METHODS: Sixteen patients (thirty-two lower limbs) with unilateral DFU were studied retrospectively. The ultrasonographic parameters including cross-sectional area (CSA) of sciatic nerve, intraneural blood flow, peak systolic velocity (Vmax) and resistive index (RI) in the intraneural artery of the sciatic nerve, and the SWE stiffness value of the sciatic nerve were measured. The examinations of arteries of the lower limbs were also performed by ultrasound. According to the presence or absence of DFU, the 32 lower limbs were divided into two groups: the DFU group and the non-DFU group. The ultrasonographic parameters were compared between these two groups. RESULTS: There was no significant difference (p > 0.05) between the two groups for CSA, intraneural blood flow, Vmax and RI in the intraneural artery of the sciatic nerve, and numbers of severe artery stenosis or full occlusion of the artery in the lower limbs. However, SWE stiffness values in the sciatic nerve in the DFU group are higher than the non-DFU group (p < 0.05). When the SWE stiffness values were used for prediction of DFU in patients with DPN, the area under the ROC curve (AUC) was 0.727 (95% CI: 0.541-0.868). When the best SWE stiffness value of 24.48 kPa was taken as a cutoff for prediction of DFU, the sensitivity was 62.50% (95% CI: 35.4-84.8%), and the specificity was 75% (95% CI: 47.6-92.7%). CONCLUSIONS: Sciatic nerve stiffness is significantly higher in lower limbs with DFU. SWE is a noninvasive imaging method that may be used to evaluate sciatic nerve stiffness, then potentially predict DFU in patients with DPN.

3.
Diagnostics (Basel) ; 13(1)2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36611436

RESUMO

OBJECTIVES: To investigate the value of subtypes of completely reversed flow (CRF) waveform in vertebral artery (VA) on Doppler ultrasound in differentiation occlusion from severe stenosis of the ipsilateral proximal subclavian artery (SA). METHODS: A total of 357 patients with CRF in the VA on Doppler US were reviewed retrospectively. Among them, 49 patients (mean age, 68.2 ± 7.8 years) confirmed by digital subtraction angiography (DSA) were included. According to the status of diastolic flow, the CRF was divided into continuous CRF (CCRF, n = 27) and intermittent CRF (ICRF, n = 22). The correlation of subtypes of CRF waveform and VA parameters with the severity of SA stenosis was evaluated. The severity of SA stenosis was determined by DSA. RESULTS: Of those 49 patients, SA occlusion was observed in 33 patients (67%, occlusion group) and severe stenosis in 16 patients (33%, stenosis group). The subtypes of CRF waveforms showed a significant between-group difference (p = 0.005). CCRF exhibited an accuracy of 85.2% (23/27) in diagnosing SA occlusion. The diameter of the target VA with ICRF showed a significant between-group difference (p = 0.041). The target VA diameter ≥ 3.8 mm in ICRF achieved an accuracy of 81.8% (18/22), and its combination with CCRF achieved an accuracy of 83.7% (41/49) in the differentiation of SA occlusion from severe stenosis. CONCLUSIONS: Subtypes of CRF in VA can help to differentiate SA occlusion from severe stenosis. CCRF has higher accuracy in diagnosing SA occlusion. The CCRF waveform plus VA diameter in ICRF is more accurate for differentiating SA occlusion from severe stenosis.

4.
Front Oncol ; 13: 1251492, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38260838

RESUMO

This report describes a rare case of double primary cancer in a female patient aged 49 years who died 2 years after diagnosis. The patient was diagnosed with BRAFV600E-mutant metastatic papillary thyroid carcinoma (PTC) and ALK fusion-positive metastatic lung adenocarcinoma. She presented with multifocal thyroid lesions and underwent radical thyroidectomy and bilateral cervical lymphadenectomy. Thyroid ultrasound revealed the presence of five hypoechoic nodules with irregular margins and microcalcifications; an irregular inhomogeneous hypoechoic level IV cervical lymph node was also found on the right side. Histological analysis confirmed the presence of metastatic PTC, and the tumor tested positive for the BRAFV600E mutation. Ultrasound of the neck, which was performed 4 months postdischarge, revealed enlargement of the left-sided cervical lymph nodes; a biopsy from these nodes confirmed a diagnosis of metastatic PTC. Positron emission tomography-computed tomography scans revealed the presence of multiple pulmonary hypermetabolic foci scattered across bilateral lung fields. Multiple hypermetabolic foci were also observed in the lymph nodes on both sides of the neck, axillae, and mediastinum; in addition, there was evidence of bone destruction with hypermetabolic foci. Supplementary reports from the histological and immunohistochemical analyses of cervical lymph node tissue obtained during primary surgery confirmed the presence of metastatic PTC and poorly differentiated lung adenocarcinoma. In particular, one enlarged cervical lymph node located on the right side of the neck demonstrated tumor components of both PTC and lung adenocarcinoma. Pathological analysis of axillary lymph node puncture biopsy confirmed the presence of metastatic lung adenocarcinoma, and gene analysis revealed the presence of ALK fusion. The patient received targeted therapy based on a multidisciplinary discussion. However, she had a poor prognosis and died 2 years after the diagnosis. The initial thyroid ultrasound findings were reviewed retrospectively; the findings suggested that the possibility of double primary cancers should be considered in cases where the enlarged cervical lymph nodes are highly suspicious of PTC and present as inhomogeneous hypoechoic masses with irregular morphology.

5.
J Ultrasound Med ; 40(12): 2655-2663, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33615538

RESUMO

OBJECTIVES: Skeletal muscle dysfunction is one of the most common comorbidities in chronic obstructive pulmonary disease (COPD). The occurrence of respiratory failure in COPD is common and leads to the patient's death. The diaphragm is the most important muscle in the respiratory system and plays a key role in the onset of respiratory failure. This study explores the feasibility of ultrasound shear wave elastography (SWE) to measure diaphragmatic stiffness and evaluates its changes in COPD patients. METHODS: In total, 77 participants (43 patients with stable COPD and 34 healthy controls) were enrolled. All subjects underwent complete diaphragmatic ultrasound SWE measurements and pulmonary function tests. The diaphragmatic stiffness was indicated via diaphragmatic shear wave velocity (SWV) at functional residual capacity (FRC). A trained operator performed the ultrasound SWE examinations of the first 15 healthy controls thrice to assess the reliability of diaphragmatic SWE. RESULTS: A good to excellent reliability was found in diaphragmatic SWV at FRC (ICC = 0.93, 95%CI 0.82-0.98). As compared to the control group, the diaphragmatic SWV at FRC was considerably high in the COPD group (median 2.5 m/s versus 2.1 m/s, P = .008). Diaphragmatic SWV at FRC was linked to forced expiratory volume in one second (r = -0.30, P = .009), forced vital capacity (r = -0.33, P = .003), modified Medical Research Council score (r = 0.30, P = .001), and COPD assessment test score (r = 0.48, P < .001). CONCLUSIONS: Ultrasound SWE may be employed as an effective tool for quantitative evaluation of diaphragm stiffness and can help in personalized management of COPD, such as treatment guidance and follow-up monitoring.


Assuntos
Técnicas de Imagem por Elasticidade , Doença Pulmonar Obstrutiva Crônica , Diafragma/diagnóstico por imagem , Humanos , Projetos Piloto , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Reprodutibilidade dos Testes
7.
Ultrasound Med Biol ; 41(5): 1328-33, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25638312

RESUMO

This study investigated the value of analyzing spectral Doppler waveform patterns and measuring the peak reversed velocity (PRV) of the vertebral artery (VA) in predicting proximal severe subclavian artery (SA) stenosis and occlusion. Fifty-one patients with proximal SA stenosis were studied retrospectively. Based on the depth of the mid-systolic notch, the Doppler waveforms of the ipsilateral VA were divided into five subtypes (type I, n = 8; type II, n = 8; type III, n = 6; type IV, n = 13; and type V, n = 16). PRV was also measured. PRV receiver operating characteristic curves were constructed to obtain the best cutoff value for predicting severe SA stenosis or complete SA occlusion. The results indicated that both VA Doppler waveform and PRV were associated with the degree of SA stenosis (p < 0.05). PRV and the Doppler waveform in the VA had similar accuracy in predicting SA occlusion (84.3%, 43/51). PRV was more accurate than VA waveforms in predicting severe SA stenosis (98%, 50/51 vs. 94.1%, 48/51). However, no significant differences between the two methods in predicting severe SA stenosis were observed (p = 0.84). Thus, with severe obstruction of the SA, typical Doppler waveform patterns of the VA could be observed. PRV is a helpful criterion in predicting severe stenosis and occlusion of the SA.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Síndrome do Roubo Subclávio/diagnóstico por imagem , Síndrome do Roubo Subclávio/fisiopatologia , Ultrassonografia Doppler/métodos , Artéria Vertebral/diagnóstico por imagem , Artéria Vertebral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Ultrasound Med Biol ; 40(9): 2004-11, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24972501

RESUMO

The aims of this study were to investigate the accuracy of using the taller-than-wide (TTW) sign in two ultrasonographic planes to predict thyroid microcarcinoma, and to confirm the hypothesis that the presence of a TTW sign in both the transverse and longitudinal ultrasonographic planes strongly suggests thyroid microcarcinoma. Nine hundred forty-two thyroid nodules ≤1 cm were submitted to surgical-histopathologic and ultrasonographic examination. TTW signs were divided into three types based on their detection only in the transverse plane (TTTW type, n = 100), only in the longitudinal plane (LTTW type, n = 61) or in both planes (BTTW type, n = 131). The areas under the receiver operating characteristic curves (A(z)) for the three different TTW signs, as well as for the combination of all TTW signs (ATTW, n = 292), were compared. The results indicated that the A(z) values of the TTTW, LTTW, BTTW and ATTW signs in predicting thyroid microcarcinoma were 0.544, 0.531, 0.627 and 0.702, respectively. The ATTW sign was the most accurate (p < 0.05), and the BTTW sign was 100% accurate for predicting thyroid microcarcinoma. However, there was no significant difference between the A(z) values for the TTTW and LTTW signs (p > 0.05). Therefore, both the LTTW and TTTW signs are reliable markers of thyroid microcarcinoma. The BTTW sign strongly suggests thyroid microcarcinoma.


Assuntos
Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Adolescente , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/cirurgia , Ultrassonografia , Adulto Jovem
9.
Ultrasound Med Biol ; 40(6): 1072-82, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24486238

RESUMO

We evaluated the causes, differential diagnosis and clinical significance of completely reversed flow (CRF) in the vertebral artery (VA). Twenty-three patients diagnosed with CRF in the VA by Doppler ultrasound were studied retrospectively. CRF was divided into intermittent CRF and continuous CRF. The peak reversed velocity (PRV) and ratio of time in intermittent CRF to one cardiac cycle (tICRF/CC) were calculated. Causes of CRF were determined on the basis of previous angiography results. The results indicated that subclavian steal phenomenon (SSP) caused all cases of continuous CRF (n = 8). Intermittent CRF was caused by SSP (n = 6) or proximal VA occlusion (n = 9). PRV and tICRF/CC were increased in SSP as compared with VA occlusion (p < 0.05). Using a cutoff of tICRF/CC = 0.30, we achieved excellent accuracy in predicting the cause of intermittent CRF (100%) and posterior circulatory infarction (91%). Thus, analysis of CRF patterns and measurements of VA parameters can be used in differential diagnosis of the causes of CRF and in prediction of posterior circulatory infarction.


Assuntos
Arteriopatias Oclusivas/diagnóstico por imagem , Síndrome do Roubo Subclávio/diagnóstico por imagem , Artéria Vertebral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Arteriopatias Oclusivas/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Síndrome do Roubo Subclávio/fisiopatologia , Ultrassonografia Doppler , Artéria Vertebral/fisiopatologia
10.
J Ultrasound Med ; 32(11): 1945-50, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24154898

RESUMO

OBJECTIVE: To evaluate the causes of bidirectional flow in the vertebral artery detected by Doppler sonography and its differential diagnosis. METHODS: Twenty-nine patients with bidirectional flow in the vertebral artery were retrospectively studied. The vertebral artery parameters, including peak antegrade velocity (PAV), peak reversed velocity (PRV), maximum peak velocity (MPV), peak systolic velocity, resistive index (RI), and diameter, were measured. The MPV was defined as the MPV of bidirectional flow regardless of the velocity of antegrade or retrograde flow. To better predict the cause of bidirectional flow, receiver operating characteristic curves were constructed for these parameters, and the best cutoff values were obtained. The cause of bidirectional flow was determined by angiography. RESULTS: The causes of bidirectional flow were classified as the subclavian steal phenomenon (n = 21) and factors unrelated to the steal phenomenon (n = 8, including a hypoplastic vertebral artery [n = 4] and proximal vertebral artery stenosis and occlusion [n = 4]). Significant differences were observed between the steal phenomenon and non-steal phenomenon groups (P< .05) for MPV, PRV, PAV, target vertebral artery diameter, and contralateral RI. To determine the cause of bidirectional flow, areas under the receiver operating characteristic curves for the different parameters were obtained: 0.929 for MPV, 0.881 for PRV, 0.824 for PAV, 0.753 for target vertebral artery diameter, and 0.845 for contralateral RI. The cutoff value for MPV was 26.1 cm/s, and the accuracy was 93% (27 of 29). CONCLUSIONS: Bidirectional flow in the vertebral artery is not always indicative of the subclavian steal phenomenon. Measurement of hemodynamic parameters in the vertebral artery, such as MPV, can facilitate determination of the cause of bidirectional flow.


Assuntos
Doença Arterial Periférica/diagnóstico por imagem , Síndrome do Roubo Subclávio/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Artéria Vertebral/diagnóstico por imagem , Insuficiência Vertebrobasilar/diagnóstico por imagem , Idoso , Velocidade do Fluxo Sanguíneo , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/fisiopatologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Síndrome do Roubo Subclávio/fisiopatologia , Artéria Vertebral/fisiopatologia , Insuficiência Vertebrobasilar/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...