Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
2.
Am J Ophthalmol ; 266: 196-205, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38810864

RESUMO

PURPOSE: To evaluate how often tests of structure and function detect glaucoma progression at the same study visit. Tests include current glaucoma clinical tests and a new 3-dimensional (3D) optical coherence tomography (OCT) rim measurement. DESIGN: Prospective cohort study. METHODS: For 124 open-angle glaucoma patients at a single institution, one eye was randomly selected for each patient. Patients were included if they had open-angle glaucoma and if they had at least 4 yearly study visits. Study visits included a full dilated eye exam, disc photography (DP), Humphrey visual field (HVF 24-2) testing, 2D OCT retinal nerve fibre layer (RNFL) thickness measurements, and 3D OCT neuroretinal rim measurements (i.e., minimum distance band or MDB). For each test at each study visit, eyes were classified as progressors or non-progressors using event-based analysis. Agreement occurred if tests progressed in the same eye at the same study visit. Agreements between all compared tests were calculated as percentages of agreement. RESULTS: The study included 124 open-angle glaucoma eyes, which had an average follow-up period of 66.9 ± 16.4 months. Structural tests (i.e., DP, global RNFL thickness, and global MDB rim thickness) progressed at the same visit as the functional test (i.e., HVF testing) in only 5.0% (3/60) to 16.0% (13/81) of eyes. Global MDB thickness and global RNFL thickness showed similar agreement with functional HVF testing (i.e., 16.0% [13/81] and 8.3% [7/84], respectively), and global MDB thickness showed better structure-function agreement with HVF testing than between DP and HVF testing (i.e., 5.0% [3/60], P = 0.04). For all paired comparisons between testing methods, eyes with moderate glaucoma showed similar or better agreement than eyes with mild or severe glaucoma. CONCLUSIONS: Clinical tests of structure and function do not usually progress at the same clinic visit. Most of the time, glaucoma progression is only detected by one or two tests.

4.
Curr Opin Ophthalmol ; 34(3): 245-254, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728784

RESUMO

PURPOSE OF REVIEW: To summarize the recent literature on deep learning (DL) model applications in glaucoma detection and surveillance using posterior segment optical coherence tomography (OCT) imaging. RECENT FINDINGS: DL models use OCT derived parameters including retinal nerve fiber layer (RNFL) scans, macular scans, and optic nerve head (ONH) scans, as well as a combination of these parameters, to achieve high diagnostic accuracy in detecting glaucomatous optic neuropathy (GON). Although RNFL segmentation is the most widely used OCT parameter for glaucoma detection by ophthalmologists, newer DL models most commonly use a combination of parameters, which provide a more comprehensive approach. Compared to DL models for diagnosing glaucoma, DL models predicting glaucoma progression are less commonly studied but have also been developed. SUMMARY: DL models offer time-efficient, objective, and potential options in the management of glaucoma. Although artificial intelligence models have already been commercially accepted as diagnostic tools for other ophthalmic diseases, there is no commercially approved DL tool for the diagnosis of glaucoma, most likely in part due to the lack of a universal definition of glaucoma defined by OCT derived parameters alone (see Supplemental Digital Content 1 for video abstract, http://links.lww.com/COOP/A54 ).


Assuntos
Glaucoma , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Inteligência Artificial , Fibras Nervosas , Células Ganglionares da Retina , Glaucoma/diagnóstico , Pressão Intraocular
5.
Semin Ophthalmol ; 38(1): 85-91, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36469549

RESUMO

Complementary and alternative medicine is used by approximately 5% of patients with glaucoma, and examples include marijuana, Ginkgo biloba extract, bilberry fruit extract, and acupuncture. Systemic marijuana is not beneficial for glaucoma due to the short duration of action, the lack of evidence that it alters disease progression, and its negative side effect profile. Drops that affect the cannabinoid pathway are still being studied. Ginkgo biloba and bilberry fruit extracts have been shown to decrease oxidative stress and improve perfusion of the optic nerve head. However, these findings are inconsistent throughout the literature and the studies are small, which makes the overall evidence weak. There is no evidence that acupuncture alters glaucoma disease progression or causes a sustained decrease in intraocular pressure. In summary, the literature suggests that there are transient and/or theoretical benefits of complementary and alternative medicine for glaucoma care; however, the overall evidence to support their use is weak.


Assuntos
Terapias Complementares , Glaucoma , Disco Óptico , Humanos , Glaucoma/tratamento farmacológico , Pressão Intraocular , Estresse Oxidativo
6.
Ophthalmology ; 130(4): 433-442, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36529572

RESUMO

PURPOSE: To review the current published literature on the utility of corneal hysteresis (CH) to assist the clinician in the diagnosis of glaucoma or in the assessment of risk for disease progression in existing glaucoma patients. METHODS: Searches of the peer-reviewed literature in the PubMed database were performed through July 2022. The abstracts of 423 identified articles were examined to exclude reviews and non-English articles. After inclusion and exclusion criteria were applied, 19 articles were selected, and the panel methodologist rated them for level of evidence. Eight articles were rated level I, and 5 articles were rated level II. The 6 articles rated level III were excluded. RESULTS: Corneal hysteresis is lower in patients with primary open-angle glaucoma, primary angle-closure glaucoma, pseudoexfoliative glaucoma, and pseudoexfoliation syndrome compared with normal subjects. Interpretation of low CH in patients with high intraocular pressure (IOP) or on topical hypotensive medications is complicated by the influence of these parameters on CH measurements. However, CH is also lower in treatment-naïve, normal-tension glaucoma patients compared with normal subjects who have a similar IOP. In addition, lower CH is associated with an increased risk of progression of glaucoma based on visual fields or structural markers in open-angle glaucoma patients, including those with apparently well-controlled IOP. CONCLUSIONS: Corneal hysteresis is lower in glaucoma patients compared with normal subjects, and lower CH is associated with an increased risk of disease progression. However, a causal relationship remains to be demonstrated. Nevertheless, measurement of CH complements current structural and functional assessments in determining disease risk in glaucoma suspects and patients. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Oftalmologia , Humanos , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Progressão da Doença , Elasticidade , Glaucoma/diagnóstico , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular , Tonometria Ocular , Estados Unidos
7.
Clin Ophthalmol ; 16: 2595-2608, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35992568

RESUMO

Purpose: To compare the reproducibility of two-dimensional (2D) peripapillary retinal nerve fiber layer (RNFL) thickness and three-dimensional (3D) neuroretinal rim measurements using spectral domain optical coherence tomography (SDOCT) in normal and glaucoma subjects. Methods: One eye per subject for 27 normal and 40 glaucoma subjects underwent repeat SDOCT RNFL thickness scans and optic nerve volume scans on the same day. From the volume scan, custom software calculated five neuroretinal rim parameters: 3D minimum distance band (MDB) thickness, 3D MDB area, 3D rim volume, 2D rim area, and 2D rim thickness. Within-subject variance (Sw), coefficient of variation (CV), and intraclass correlation coefficient (ICC) were analyzed. Results: MDB thickness and RNFL thickness have similar reproducibility among normal and glaucoma subjects (eg, global MDB thickness CVs of 2.4% and 3.6%, and global RNFL thickness CVs of 1.3% and 2.2%; P > 0.05 for both comparisons). Reproducibility of MDB thickness was lower in glaucoma patients for the superior and inferior quadrants compared to normal subjects (CVs of 9.6% versus 3.4% and 6.9% versus 2.7%; P < 0.05, respectively). There were no statistically significant differences between both groups for RNFL thickness in the four quadrants. For both patient groups and for all regions, MDB thickness had the lowest CVs among all five neuroretinal rim parameters (eg, global MDB thickness CVs of 2.4% and 3.6% versus 3.0% and 18.9% for the other four neuroretinal rim parameters). Conclusion: Global MDB and global RNFL thickness are similarly reproducible among normal and glaucoma subjects, though MDB thickness for the superior and inferior quadrants is less reproducible among glaucoma subjects.

8.
Am J Ophthalmol Case Rep ; 27: 101638, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35813588

RESUMO

Purpose: To report two pediatric cases of reticular corneal epithelial edema associated with the use of netarsudil ophthalmic solution 0.02%. Observations: In Case 1, a six-year-old male with glaucoma following cataract surgery was treated with netarsudil for thirteen months and developed diffuse reticular corneal epithelial edema on post-operative day one after undergoing transscleral diode cyclophotocoagulation for persistently elevated intraocular pressures. In Case 2, a three-month-old male with bilateral ocular hypertension developed unilateral inferior reticular corneal epithelial edema five weeks after initiation of netarsudil, which had been discontinued in the fellow eye two weeks prior. In both cases, the reticular epithelial edema resolved following cessation of netarsudil. Conclusions and Importance: Netarsudil-associated reticular corneal epithelial edema can occur in infants and young children.

9.
Clin Ophthalmol ; 16: 2305-2310, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35903751

RESUMO

Purpose: To assess practice patterns and opinions of glaucoma specialists regarding glaucoma drainage device tube shunt placement and post-operative anti-inflammatory medication use. We also assess the perceived need for a randomized control trial to compare them. Patients and Methods: An online survey was distributed to a group of glaucoma specialists from the American Glaucoma Society via the American Glaucoma Society forum from April to August 2021. Results: One hundred and twenty-eight responses were included. Ninety percent placed tubes in the anterior chamber. Sixty-one percent reported that evidence suggested the superiority of sulcus tube placement over the anterior chamber, whereas 34% reported there was not enough evidence to suggest superiority of either in preventing endothelial cell loss. Comparing these techniques for intraocular pressure control, 49% reported evidence suggested sulcus tube placement superiority whereas 46% reported there was not enough evidence. Over 40% of respondents reported that they were either unfamiliar with literature or that there was not enough evidence to support the superiority of difluprednate 0.05% over prednisolone 1% for post-operative use in preventing endothelial cell loss and for intraocular pressure control. Ninety percent and 81% of respondents respectively would benefit from randomized control trials comparing outcomes of anterior chamber vs sulcus tube placement and post-operative corticosteroid usage. Conclusion: Most glaucoma specialists surveyed place glaucoma drainage device tube in the anterior chamber over the sulcus. A randomized control trial to determine optimal tube placement and post-operative anti-inflammatory medication use for preventing endothelial cell loss would change current glaucoma drainage device practice patterns.

10.
Am J Ophthalmol ; 243: 42-54, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35850253

RESUMO

PURPOSE: To assess clinical outcomes of patients with severe, cicatricial ocular surface disease (OSD) implanted with the currently marketed design of the Boston keratoprosthesis type II (BK2). DESIGN: Retrospective cohort study. METHODS: Records of consecutive patients undergoing BK2 implantation from June 2009 to March 2021 were assessed for postoperative visual acuity, postoperative complications, device replacement, and additional surgeries. RESULTS: Fifty-six eyes of 53 patients with a mean follow-up of 45.8 months (range, 0.2-134.7 months) were included. Stevens-Johnson syndrome/toxic epidermal necrolysis was the most common indication (49.1%), followed by mucous membrane pemphigoid (39.6%) and other OSD (11.3%). Visual acuity improved from logMAR 2.2 ± 0.5 preoperatively to 1.5 ± 1.2 at final follow-up. Of 56 eyes, 50 saw ≥20/200 at some point postoperatively. Of the eyes with a follow-up of more than 5 years, 50.0% retained a visual acuity of ≥20/200 at their final follow-up. The most common complications over the entire postoperative course (mean ∼4 years) were de novo or worsening glaucoma (41.1%), choroidal effusions (30.3%), retinal detachment (25.0%), and end-stage glaucoma (25.0%). In a univariate analysis, patients who experienced irreversible loss of ≥20/200 visual acuity were more likely to have been previously implanted with an older design of BK2, less likely to be on preoperative systemic immunosuppressive therapy, and less likely to have undergone concurrent glaucoma tube implantation, compared to patients who retained ≥20/200 acuity (P < .04 for all). CONCLUSIONS: Advances in device design and postoperative care have made implantation of BK2 a viable option for corneal blindness in the setting of severe cicatricial OSD.


Assuntos
Doenças da Córnea , Glaucoma , Humanos , Córnea/cirurgia , Próteses e Implantes , Doenças da Córnea/cirurgia , Estudos Retrospectivos , Implantação de Prótese , Glaucoma/cirurgia
11.
Ophthalmol Glaucoma ; 5(5): 498-506, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35288335

RESUMO

PURPOSE: Clinicians use both global and point-wise information from visual fields to assess the rate of glaucomatous functional progression. We asked which objective, quantitative measures best correlated with subjective assessment by glaucoma experts. In particular, we aimed to determine how much that judgment was based on localized rates of change vs. on global indices reported by the perimeter. DESIGN: Prospective cohort study. PARTICIPANTS: Eleven academic, expert glaucoma specialists independently scored the rate of functional progression, from 1 (improvement) to 7 (very rapid progression), for a series of 5 biannual clinical printouts from 100 glaucoma or glaucoma suspect eyes of 51 participants, 20 of which were scored twice to assess repeatability. METHODS: Regression models were used to predict the average of the 11 clinicians' scores based on objective rates of change of mean deviation (MD), visual field index (VFI), pattern standard deviation (PSD), the Nth fastest progressing location, and the Nth fastest progressing of 10 anatomically defined clusters of locations after weighting by eccentricity. MAIN OUTCOME MEASURES: Correlation between the objective rates of change and the average of the 11 clinicians' scores. RESULTS: The average MD of the study eyes was -2.4 dB (range, -16.8 to +2.8 dB). The mean clinician score was highly repeatable, with an intraclass correlation coefficient of 0.95. It correlated better with the rate of change of VFI (pseudo-R2 = 0.73, 95% confidence interval [CI, 0.60-0.83]) than with MD (pseudo-R2 = 0.63, 95% CI [0.45-0.76]) or PSD (pseudo-R2 = 0.41, 95% CI [0.26-0.55]). Using point-wise information, the highest correlations were found with the fifth-fastest progressing location (pseudo-R2 = 0.71, 95% CI [0.56-0.80]) and the fastest-progressing cluster after eccentricity weighting (pseudo-R2 = 0.61, 95% CI [0.48-0.72]). Among 25 eyes with an average VFI of > 99%, the highest observed pseudo-R2 value was 0.34 (95% CI [0.16-0.61]) for PSD. CONCLUSIONS: Expert academic glaucoma specialists' assessment of the rate of change correlated best with VFI rates, except in eyes with a VFI near the ceiling of 100%. Sensitivities averaged within clusters of locations have been shown to detect change sooner, but the experts' opinions correlated more closely with global VFI. This could be because it is currently the only index for which the perimeter automatically provides a quantitative estimate of the rate of functional progression.


Assuntos
Glaucoma , Testes de Campo Visual , Progressão da Doença , Glaucoma/diagnóstico , Humanos , Estudos Prospectivos , Transtornos da Visão/diagnóstico , Testes de Campo Visual/métodos
13.
Am J Ophthalmol Case Rep ; 25: 101287, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35146185

RESUMO

PURPOSE: To describe 8 cases of reversible reticular corneal epithelial edema of the cornea that developed after use of the topical Rho-kinase inhibitor netarsudil. METHODS: This is a retrospective chart review case series of 8 patients treated with netarsudil at an academic medical center. OBSERVATIONS: Patients had predisposing corneal conditions including penetrating keratoplasty, corneal decompensation after trabeculectomy-associated endophthalmitis, congenital glaucoma with Haab striae, aphakic bullous keratopathy, history of Ahmed valve and silicone oil, and Fuchs endothelial corneal dystrophy undergoing Descemet stripping only. One patient did not have clear predisposing corneal disease other than low endothelial cell density and a history of trabeculectomy. All patients developed reticular corneal epithelial edema, which appeared as collections of moderate sized superficial epithelial bullae arranged in a reticular pattern resembling a honeycomb. Most developed these changes within weeks of initiating netarsudil, but unique to this series are 2 cases in which netarsudil was tolerated by the cornea for months before developing reticular corneal epithelial edema after diode laser cyclophotocoagulation. In cases which underwent anterior segment optical coherence tomography, the imaging demonstrated that the corneal stroma was not edematous, and the reticular corneal epithelial edema involved both host and donor corneal epithelium in cases of penetrating keratoplasty. This fully resolved in all cases upon cessation of netarsudil, and this series is the first to document resolution via a pattern in which the individual bullae become smaller and more widely spaced apart. CONCLUSION: Netarsudil can cause a reversible reticular corneal epithelial edema.

14.
Ophthalmol Glaucoma ; 5(5): 507-515, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35144008

RESUMO

PURPOSE: OCT scans contain large amounts of information, but clinicians often rely on reported layer thicknesses when assessing the rate of glaucomatous progression. We sought to determine which of these quantifications most closely relate to the subjective assessment of glaucoma experts who had all the diagnostic information available. DESIGN: Prospective cohort study. PARTICIPANTS: Eleven glaucoma specialists independently scored the rate of structural progression from a series of 5 biannual clinical OCT printouts. METHODS: A total of 100 glaucoma or glaucoma suspect eyes of 51 participants were included; 20 were scored twice to assess repeatability. Scores ranged from 1 (improvement) to 7 (very rapid progression). Generalized estimating equation linear models were used to predict the mean clinician score from the rates of change of retinal nerve fiber layer thickness (RNFLT) or minimum rim width (MRW) globally or in the most rapidly thinning of the 6 sectors. MAIN OUTCOME MEASURES: The correlation between the objective rates of change and the average of the 11 clinicians' scores. RESULTS: Average RNFLT within the series of study eyes was 79.3 µm (range, 41.4-126.6). Some 95% of individual clinician scores varied by ≤ 1 point when repeated. The mean clinician score was more strongly correlated with the rate of change of RNFLT in the most rapidly changing sector in %/year (pseudo-R2 = 0.657) than the rate of global RNFLT (0.372). The rate of MRW in the most rapidly changing sector had pseudo-R2 = 0.149. CONCLUSIONS: The rate of change of RNFLT in the most rapidly changing sector predicted experts' assessment of the rate of structural progression better than global rates or MRW. Sectoral rates may be a useful addition to current clinical printouts.


Assuntos
Glaucoma , Disco Óptico , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Fibras Nervosas , Estudos Prospectivos , Células Ganglionares da Retina , Tomografia de Coerência Óptica/métodos
16.
Am J Ophthalmol ; 234: 188-198, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34214455

RESUMO

PURPOSE: To evaluate the relationship between the occurrence of optic disc hemorrhages (DH) and glaucoma progression as determined by multiple glaucoma testing modalities. DESIGN: Prospective cohort study. METHODS: A longitudinal study was undertaken of 124 open-angle glaucoma patients who had yearly disc photography, visual fields (VFs), spectral-domain optical coherence tomography (SD-OCT), retinal nerve fiber layer (RNFL) thickness scans, and optic nerve volume scans (Spectralis), all performed on the same day over a 5-year period. The minimum distance band (MDB) thickness, a 3-dimensional (3D) neuroretinal rim parameter, was calculated from optic nerve volume scans. Patients were classified as glaucoma progressors or glaucoma nonprogressors using event-based analysis. RESULTS: Of 124 open-angle glaucoma patients, 19 (15.3%) had 1 or more DHs on yearly disc photographs. Presence of a DH was associated with localized 3D neuroretinal rim thickness progression (superior MDB progression; odds ratio: 3.96; P = .04) but not with global or inferior MDB progression (P = .14 and .81, respectively), DP progression (P = .08), VF progression (P = .45), or RNFL global, inferior, or superior progression (P = .17, .26, and .76, respectively). In the majority of patients with MDB progression (14/17 or 82%), the progression was noted before or concurrently with the first instance of DH. CONCLUSIONS: Glaucoma progression detected by high-density 3D SD-OCT neuroretinal rim measurements preceded DH occurrence in the majority of patients. These findings support the hypothesis that DHs are indicators of ongoing glaucoma progression rather than discrete events that cause subsequent progression.


Assuntos
Glaucoma de Ângulo Aberto , Disco Óptico , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/diagnóstico , Hemorragia , Humanos , Pressão Intraocular , Estudos Longitudinais , Fibras Nervosas , Estudos Prospectivos , Células Ganglionares da Retina , Tomografia de Coerência Óptica/métodos
17.
Curr Opin Ophthalmol ; 33(2): 103-111, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34864763

RESUMO

PURPOSE OF REVIEW: To summarize the literature on three-dimensional (3D) technological advances in ophthalmology, the quantitative methods associated with this, and their improved ability to help detect glaucoma disease progression. RECENT FINDINGS: Improvements in measuring glaucomatous structural changes are the result of dual innovations in optical coherence tomography (OCT) imaging technology and in associated quantitative software. SUMMARY: Compared with two-dimensional (2D) OCT parameters, newer 3D parameters provide more data and fewer artifacts.


Assuntos
Glaucoma , Oftalmologia , Glaucoma/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Tecnologia , Tomografia de Coerência Óptica
18.
Digit J Ophthalmol ; 28(4): 100-109, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36660188

RESUMO

Purpose: To determine whether intereye asymmetry of a three-dimensional neuroretinal rim parameter, the minimum distance band, is useful in differentiating normal eyes from those with open-angle glaucoma. Materials and Methods: This is a cross-sectional study of 28 normal subjects and 33 glaucoma subjects. Subjects underwent spectral domain optical coherence tomography imaging of both eyes. From high-density raster scans of the optic nerve head, a custom-designed segmentation algorithm calculated mean minimum distance band neuroretinal rim thickness globally, for four quadrants, and for four sectors. Intereye minimum distance band thickness asymmetry was calculated as the absolute difference in minimum distance band thickness values between the right and left eyes. Results: Increasing global minimum distance band thickness asymmetry was not associated with increasing age or increasing refractive error asymmetry. Glaucoma patients had thinner mean neuroretinal rim thickness values compared to normal patients (209.0 µm vs 306.0 µm [P < 0.001]). Glaucoma subjects had greater intereye thickness asymmetry compared to normal subjects for the global region (51.9 µm vs 17.6 µm [P < 0.001]) as well as for all quadrants and all sectors. For detecting glaucoma, a thickness asymmetry value >28.3 µm in the inferior quadrant yielded the greatest sum of sensitivity (87.9%) and specificity (75.0%). Globally, thickness asymmetry >30.7 µm yielded the greatest sum of sensitivity (66.7%) and specificity (89.3%). Conclusions: This study indicates that intereye neuroretinal rim minimum distance band asymmetry measurements, using high-density spectral domain optical coherence tomography volume scans, may be an objective and quantitative tool for assessing patients suspected of open-angle glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Glaucoma de Ângulo Aberto/diagnóstico , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Pressão Intraocular , Células Ganglionares da Retina , Glaucoma/diagnóstico
19.
Transl Vis Sci Technol ; 10(6): 28, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-34019635

RESUMO

Purpose: To assess the structure-function relationship in glaucoma using Humphrey visual field (HVF) perimetry and a three-dimensional neuroretinal rim parameter derived from spectral domain optical coherence tomography (SD-OCT) volume scans. Methods: Structure-function correlation was analyzed globally and regionally (four quadrants and four sectors). Structural data included peripapillary retinal nerve fiber layer (RNFL) thickness and minimum distance band (MDB) neuroretinal rim thickness, defined as the shortest distance between the inner cup surface and the outer retinal pigment epithelium/Bruch's membrane complex. Logarithmic regression analyses were performed and Pearson correlation coefficients determined to assess relationship strength. Results: The study consisted of 102 open-angle glaucoma patients and 58 healthy subjects. The Pearson correlation coefficient for global MDB thickness (R = 0.585) was higher than for global RNFL thickness (R = 0.492), but the difference was not statistically significant (P = 0.18). The correlation coefficients for regional MDB thicknesses and corresponding HVF sensitivities were higher than those for regional RNFL thicknesses and HVF in six out of eight regions (P = 0.08 to 0.47). In the remaining two out of eight regions, the correlation coefficients were higher for RNFL thickness than for MDB thickness (P = 0.15 to 0.20). Conclusions: Three-dimensional MDB neuroretinal rim thickness relates to visual function as strongly as the most commonly used SD-OCT parameter for glaucoma, two-dimensional peripapillary RNFL thickness. Translational Relevance: This paper illustrates the potential for 3D OCT algorithms to improve in vivo imaging in glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Disco Óptico , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Fibras Nervosas , Disco Óptico/diagnóstico por imagem , Células Ganglionares da Retina , Tomografia de Coerência Óptica
20.
Ophthalmol Glaucoma ; 4(6): 604-616, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33774215

RESUMO

PURPOSE: To compare onset times of glaucoma progression among different glaucoma tests: disc photography (DP), visual field (VF) testing, 2-dimensional (2D) retinal nerve fiber layer (RNFL) thickness, and 3-dimensional (3D) spectral-domain (SD) OCT neuroretinal rim measurements. DESIGN: Prospective, longitudinal cohort study. PARTICIPANTS: One hundred twenty-four eyes of 124 patients with open-angle glaucoma. METHODS: Over a 5-year period, 124 patients with open-angle glaucoma underwent yearly DP, VF testing, SD OCT RNFL thickness scans, and optic nerve volume scans (Spectralis; Heidelberg Engineering), all performed on the same day. From high-density optic nerve volume scans, custom-built software calculated the minimum distance band (MDB) thickness, a 3D neuroretinal rim parameter. Patients were classified as glaucoma progressors or nonglaucoma progressors using event-based analysis. Progression by DP and VF testing occurred when 3 masked glaucoma specialists unanimously concurred. Progression by RNFL and MDB thickness occurred if change of more than test-retest variability was observed. Kaplan-Meier curves were constructed to analyze time-to-progression data. Kappa Coefficients were used to measure agreement of progressing eyes among methods. MAIN OUTCOME MEASURES: Time to glaucoma progression among all 4 methods. RESULTS: Global MDB thickness detected glaucoma progression in the highest percentage of eyes (52.4%) compared with DP (16.1%; P < 0.001) and global RNFL thickness (15.3%; P < 0.001). Global MDB thickness detected glaucoma progression earlier than either DP (23 months vs. 44 months; P < 0.001) or global RNFL thickness (23 months vs. 33 months; P < 0.001). Among MDB progressing eyes, 46.2% were confirmed simultaneously or later by other conventional methods. Agreement of glaucoma-progressing eyes for all 4 methods in paired fashion were slight to fair (κ = 0.095-0.300). CONCLUSIONS: High-density 3D SD OCT neuroretinal rim measurements detected glaucoma progression approximately 1 to 2 years earlier compared with current clinically available structural tests (i.e., DP and 2D RNFL thickness measurements).


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Humanos , Estudos Longitudinais , Nervo Óptico , Estudos Prospectivos , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...