Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
RSC Adv ; 14(24): 17195-17201, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38808247

RESUMO

The chemical screening of an octocoral identifed as Junceella fragilis has led to the isolation of five chlorinated briarane-type diterpenoids, including three known metabolites, gemmacolide X (1), frajunolide I (2), and fragilide F (3), along with two new analogs, 12α-acetoxyfragilide F (4) and 12α-acetoxyjunceellin (5). Single-crystal X-ray diffraction analysis was carried out to determine the absolute configurations of 1 and 2, while the structures of new compounds 4 and 5 were ascertained with 2D NMR experiments. Briaranes 1 and 3-5 were active in enhancing alkaline phosphatase (ALP) activity.

2.
BMC Musculoskelet Disord ; 22(1): 127, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33522921

RESUMO

BACKGROUND: Acromioclavicular joint (ACJ) dislocation is a relatively common shoulder injury. For the treatment of cases of severe ACJ dislocation (Rockwood type III-V), hook plate fixation is an easy-to-master and minimally-invasive approach to surgical intervention. Over stress on the acromion following hook plate fixation often leads to acromial complications such as osteolysis and loss of reduction. We hypothesized that suspensory reconstruction alongside hook plate fixation might provide a superior stability and reduce complications as compared with hook plate fixation alone. The purpose of the study was to assess the clinical and radiographic outcomes of these two surgical modalities. METHODS: We retrospectively enrolled 49 patients with acute ACJ dislocation from May 2010 to December 2018. Among them, 19 patients received hook plate fixation only (HP group), and 19 underwent concomitant hook plate fixation and loop suspension fixation with two mersilene sutures (HM group). The demographic data of the patients were recorded and analyzed. All patients underwent a shoulder X-ray initially, immediately postoperatively, and at 1, 3, 6 and 12 months to measure the relative coracoclavicular distance (rCCD). Clinical assessment of shoulder function outcome was conducted using the Constant Murley Score (CMS); the University of California at Los Angeles (UCLA) Shoulder Score was also measured at the latest follow-up. RESULTS: There were no significant differences in the demographic data between the two groups. With regards to the CMS and the UCLA score, the HM group and HP group both had excellent outcomes, and no significant differences in scores were observed between groups (CMS: 93.90 ± 6.16 versus 94.47 ± 7.26, p = 0.47; UCLA score: 32.84 ± 2.91 versus 34.32 ± 1.16, p = 0.07). However, the HM group demonstrated substantial superiority in terms of maintenance of the rCCD over the HP group (91.47 ± 27.47 versus 100.75 ± 48.70, p = 0.015). In addition, there was less subacromial osteolysis in the HM group than the HP group (52.6% versus 15.8%, p = 0.038). CONCLUSION: Both fixations yielded excellent functional outcomes. However, concomitant hook plate fixation with loop suspensory reconstruction demonstrated the fewer acromion complications and statistical differences in reduction maintenance with less clinical significance.


Assuntos
Articulação Acromioclavicular , Luxações Articulares , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/cirurgia , Placas Ósseas , Humanos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
3.
Sensors (Basel) ; 18(11)2018 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-30423845

RESUMO

This study designs and characterizes a novel precise measurement system for simultaneously measuring six-degree-of-freedom geometric motion errors of a long linear stage of a machine tool. The proposed measurement system is based on a method combined with the geometrical optics method and laser interferometer method. In contrast to conventional laser interferometers using only the interferometer method, the proposed measurement system can simultaneously measure six-degree-of-freedom geometric motion errors of a long linear stage with lower cost and faster operational time. The proposed measurement system is characterized numerically using commercial software ZEMAX and mathematical modeling established by using a skew-ray tracing method, a homogeneous transformation matrix, and a first-order Taylor series expansion. The proposed measurement system is then verified experimentally using a laboratory-built prototype. The experimental results show that, compared to conventional laser interferometers, the proposed measurement system better achieves the ability to simultaneously measure six-degree-of-freedom geometric errors of a long linear stage (a traveling range of 250 mm).

4.
Sensors (Basel) ; 16(7)2016 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-27409619

RESUMO

Automated optical inspection is a very important technique. For this reason, this study proposes an optical non-contact slanting surface measuring system. The essential features of the measurement system are obtained through simulations using the optical design software Zemax. The actual propagation of laser beams within the measurement system is traced by using a homogeneous transformation matrix (HTM), the skew-ray tracing method, and a first-order Taylor series expansion. Additionally, a complete mathematical model that describes the variations in light spots on photoelectric sensors and the corresponding changes in the sample orientation and distance was established. Finally, a laboratory prototype system was constructed on an optical bench to verify experimentally the proposed system. This measurement system can simultaneously detect the slanting angles (x, z) in the x and z directions of the sample and the distance (y) between the biconvex lens and the flat sample surface.

5.
Appl Opt ; 51(16): 3660-9, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22695607

RESUMO

Although widely recognized as a promising candidate for the next generation of data storage devices, holographic data storage systems (HDSS) incur adverse effects such as noise, misalignment, and aberration. Therefore, based on the structural similarity (SSIM) concept, this work presents a more accurate locating approach than the gray level weighting method (GLWM). Three case studies demonstrate the effectiveness of the proposed approach. Case 1 focuses on achieving a high performance of a Fourier lens in HDSS, Cases 2 and 3 replace the Fourier lens with a normal lens to decrease the quality of the HDSS, and Case 3 demonstrates the feasibility of a defocus system in the worst-case scenario. Moreover, the bit error rate (BER) is evaluated in several average matrices extended from the located position. Experimental results demonstrate that the proposed SSIM method renders a more accurate centering and a lower BER, lower BER of 2 dB than those of the GLWM in Cases 1 and 2, and BER of 1.5 dB in Case 3.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...