Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Autom Reason ; 66(4): 989-1030, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36353685

RESUMO

SQL is the world's most popular declarative language, forming the basis of the multi-billion-dollar database industry. Although SQL has been standardized, the full standard is based on ambiguous natural language rather than formal specification. Commercial SQL implementations interpret the standard in different ways, so that, given the same input data, the same query can yield different results depending on the SQL system it is run on. Even for a particular system, mechanically checked formalization of all widely-used features of SQL remains an open problem. The lack of a well-understood formal semantics makes it very difficult to validate the soundness of database implementations. Although formal semantics for fragments of SQL were designed in the past, they usually did not support set and bag operations, lateral joins, nested subqueries, and, crucially, null values. Null values complicate SQL's semantics in profound ways analogous to null pointers or side-effects in other programming languages. Since certain SQL queries are equivalent in the absence of null values, but produce different results when applied to tables containing incomplete data, semantics which ignore null values are able to prove query equivalences that are unsound in realistic databases. A formal semantics of SQL supporting all the aforementioned features was only proposed recently. In this paper, we report about our mechanization of SQL semantics covering set/bag operations, lateral joins, nested subqueries, and nulls, written in the Coq proof assistant, and describe the validation of key metatheoretic properties. Additionally, we are able to use the same framework to formalize the semantics of a flat relational calculus (with null values), and show a certified translation of its normal forms into SQL.

2.
J Hepatol ; 77(5): 1276-1286, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35716846

RESUMO

BACKGROUND & AIMS: With or without antiviral treatment, few individuals achieve sustained functional cure of chronic hepatitis B virus (HBV) infection. A better definition of what mediates functional cure is essential for improving immunotherapeutic strategies. We aimed to compare HBV-specific T cell responses in patients with different degrees of viral control. METHODS: We obtained blood from 124 HBV-infected individuals, including those with acute self-limiting HBV infection, chronic infection, and chronic infection with functional cure. We screened for HBV-specific T cell specificities by ELISpot, assessed the function of HBV-specific T cells using intracellular cytokine staining, and characterized HBV-specific CD4 T cells using human leukocyte antigen (HLA) class II tetramer staining, all directly ex vivo. RESULTS: ELISpot screening readily identified HBV-specific CD4 and CD8 T cell responses in acute resolving infection compared with more limited reactivity in chronic infection. Applying more sensitive assays revealed higher frequencies of functional HBV-specific CD4 T cells, but not CD8 T cells, in functional cure compared to chronic infection. Function independent analysis using HLA multimers also identified more HBV-specific CD4 T cell responses in functional cure compared to chronic infection, with the emergence of CD4 T cell memory both after acute and chronic infection. CONCLUSIONS: Functional cure is associated with higher frequencies of functional HBV-specific CD4 memory T cell responses. Thus, immunotherapeutic approaches designed to induce HBV functional cure should also aim to improve CD4 T cell responses. LAY SUMMARY: Immunotherapy is a form of treatment that relies on harnessing the power of an individual's immune system to target a specific disease or pathogen. Such approaches are being developed for patients with chronic HBV infection, in an attempt to mimic the immune response in patients who control HBV infection spontaneously, achieving a so-called functional cure. However, what exactly defines protective immune responses remains unclear. Herein, we show that functional cure is associated with robust responses by HBV-specific CD4 T cells (a type of immune cell).


Assuntos
Hepatite B Crônica , Hepatite B , Antígenos de Superfície/uso terapêutico , Antivirais/uso terapêutico , Linfócitos T CD4-Positivos , Linfócitos T CD8-Positivos , Citocinas , Hepatite B/tratamento farmacológico , Vírus da Hepatite B , Hepatite B Crônica/tratamento farmacológico , Humanos
3.
Nat Immunol ; 22(8): 1030-1041, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34312544

RESUMO

T cell exhaustion is associated with failure to clear chronic infections and malignant cells. Defining the molecular mechanisms of T cell exhaustion and reinvigoration is essential to improving immunotherapeutic modalities. Here we confirmed pervasive phenotypic, functional and transcriptional differences between memory and exhausted antigen-specific CD8+ T cells in human hepatitis C virus (HCV) infection before and after treatment. After viral cure, phenotypic changes in clonally stable exhausted T cell populations suggested differentiation toward a memory-like profile. However, functionally, the cells showed little improvement, and critical transcriptional regulators remained in the exhaustion state. Notably, T cells from chronic HCV infection that were exposed to antigen for less time because of viral escape mutations were functionally and transcriptionally more similar to memory T cells from spontaneously resolved HCV infection. Thus, the duration of T cell stimulation impacts exhaustion recovery, with antigen removal after long-term exhaustion being insufficient for the development of functional T cell memory.


Assuntos
Linfócitos T CD8-Positivos/imunologia , Linfócitos T CD8-Positivos/patologia , Hepacivirus/imunologia , Hepatite C Crônica/imunologia , Memória Imunológica/imunologia , Antivirais/uso terapêutico , Diferenciação Celular/imunologia , Epitopos/genética , Hepatite C Crônica/tratamento farmacológico , Humanos , Fenótipo
4.
Preprint em Inglês | Fiocruz Preprints | ID: ppf-49718

RESUMO

T cell exhaustion is associated with failure to clear chronic infections and malignant cells. Defining the molecular mechanisms of T cell exhaustion and reinvigoration is essential to improving immunotherapeutic modalities. Analysis of antigen-specific CD8+ T cells before and after antigen removal in human hepatitis C virus (HCV) infection confirmed pervasive phenotypic, functional, and transcriptional differences between exhausted and memory CD8+ T cells. After viral cure, we observed broad phenotypic and transcriptional changes in clonally stable exhausted T-cell populations suggesting differentiation towards a memory-like profile. However, functionally, the cells showed little improvement and critical transcriptional regulators remained in the exhaustion state. Notably, T cells from chronic HCV infection that were exposed to antigen for shorter periods of time because of viral escape mutations were functionally and transcriptionally more similar to memory T cells from spontaneously resolved acute HCV infection. Thus, duration of T cell stimulation impacts the ability to recover from exhaustion, as antigen removal after long-term T cell exhaustion is insufficient for the development of key T cell memory characteristics.

5.
Gut ; 68(5): 893-904, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30580250

RESUMO

OBJECTIVE: Chronic HBV infection affects more than 250 million people worldwide and remains a global healthcare problem in part because we lack curative treatment. Sustained viral control requires HBV-specific T cells, but these become functionally impaired in chronic infection. Clinical evidence indicates that functional cure of HBV infection by the host immune response is feasible. Developing T cell-based therapies able to achieve functional cure will require identification of the requirements for a successful T cell response against HBV and the relative contribution of individual T cell specificities to HBV control. DESIGN: The phenotype and function of HBV-specific T cells were studied directly ex vivo using fluorochrome-labelled multimers. We studied multiple HBV-specific T cell specificities targeting different HBV proteins in individuals with either an acute self-limiting or chronic HBV infection. RESULTS: We detected strong T cell responses targeting multiple HBV viral proteins in acute self-limiting and low-frequency core and polymerase-specific T cells in chronic infection. Expression of the T cell inhibitory receptor PD-1, as well as T cell differentiation, T cell function and T cell regulation differed by stages and outcomes of infection. In addition, these features differed significantly between T cells targeting different HBV specificities. CONCLUSION: HBV-specific T cells with different target specificities are characterised by distinct phenotypical and functional profiles. These results have direct implications for the design of immunological studies in HBV infection, and are potentially relevant for informing immunotherapeutic approaches to induce functional cure.


Assuntos
Linfócitos T CD8-Positivos/fisiologia , Epitopos , Vírus da Hepatite B/imunologia , Hepatite B Crônica/etiologia , Receptor de Morte Celular Programada 1/metabolismo , Adulto , Idoso , Feminino , Hepatite B Crônica/metabolismo , Hepatite B Crônica/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Fenótipo
6.
J Pharm Biomed Anal ; 55(3): 429-34, 2011 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21398064

RESUMO

A multivariate calibration approach using near-infrared (NIR) spectroscopy for determining blend uniformity end-point of a pharmaceutical solid dosage form containing 29.4% (w/w) drug load with three major excipients (crospovidone, lactose, and microcrystalline cellulose) is presented. A set of 21 off-line, static calibration samples were used to develop a multivariate partial least-squares (PLS) calibration model for on-line predictions of the API content during the blending process. The concentrations of the API and the three major excipients were varied randomly to minimize correlations between the components. A micro-electrical-mechanical-system (MEMS) based NIR spectrometer was used for this study. To minimize spectral differences between the static and dynamic measurement modes, the acquired NIR spectra were preprocessed using standard normal variate (SNV) followed by second derivative Savitsky-Golay using 21 points. The performance of the off-line PLS calibration model were evaluated in real-time on 67 production scale (750L bin size) blend experiments conducted over 3 years. The real-time API-NIR (%) predictions of all batches ranged from 93.7% to 104.8% with standard deviation ranging from 0.5% to 1.8%. These results showed the attainment of blend homogeneity and were confirmed with content uniformity by HPLC of respective manufactured tablets values ranging from 95.4% to 101.3% with standard deviation ranging from 0.5% to 2.1%. Furthermore, the performance of the PLS calibration model was evaluated against off-target batches manufactured with high and low amounts of water during the granulation phase of production. This approach affects the particle size and hence blending. All the off-target batches exhibited API-NIR (%) predictions of 94.6% to 103.5% with standard deviation ranging from 0.7% to 1.9%. Using off-target data, a systematic approach was developed to determine blend uniformity end-point. This was confirmed with 3 production scale batches whereby the blend uniformity end-point was determined using the PLS calibration model. Subsequently, the uniformity was also ascertained with conventional thief sampling followed by HPLC analysis and content uniformity by HPLC of the manufactured tablets.


Assuntos
Composição de Medicamentos/métodos , Determinação de Ponto Final , Preparações Farmacêuticas/análise , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Calibragem , Cromatografia Líquida de Alta Pressão , Excipientes/química , Análise dos Mínimos Quadrados , Modelos Teóricos , Análise Multivariada , Preparações Farmacêuticas/química , Reprodutibilidade dos Testes , Comprimidos
7.
Analyst ; 134(7): 1405-15, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19562209

RESUMO

Robust NIR transmission spectroscopic methods have been developed for determination of content uniformity (CU) of pharmaceutical products with a complex tablet matrix. The tablets of interest, formulated with eight components with active drug load of approximately 30% (w/w), are non-film coated, embossed, and round with thickness values of 3.6 and 5.6 mm, for the 125 and 500 mg dosage strength, respectively. The calibration data set contained seven laboratory scale batches of tablets with concentration range of active pharmaceutical ingredients (API) varying from 85 to 115% relative to label claim (LC) as well as four full scale production batches of tablets that included the natural physical variability of tablets. The reference concentration values were established by a high performance liquid chromatographic method. Partial least-squares (PLS) regression method was used to generate the calibration models. The root mean squared error of calibration for 125 and 500 mg was 1.6 and 1.5% in LC, respectively. The calibration models were validated in terms of measurement accuracy, repeatability, precision, robustness and transferability. Robustness assessment involved challenging the model with tablets incorporating variations in hardness, excipient vendors, excipient content and excipient particle size. The methods exhibited excellent measurement accuracy based on 87 batches (ten tablets for each batch) evaluated. The transferability of the developed NIR methods was demonstrated by comparing the NIR CU results associated with the same set of tablets scanned at the development site with those scanned at the production site. The result indicates that the NIR method can be used as a suitable alternative to the HPLC method for rapid tablet CU release test in pharmaceuticals.


Assuntos
Preparações Farmacêuticas/análise , Espectrofotometria Infravermelho/métodos , Cromatografia Líquida de Alta Pressão , Análise Multivariada , Reprodutibilidade dos Testes , Espectrofotometria Infravermelho/instrumentação , Comprimidos , Fatores de Tempo
8.
Appl Spectrosc ; 63(1): 33-47, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19146717

RESUMO

This paper examines how one may assess spectral changes with instrument configuration (or composition), in combination with the spectral changes in the measurement that are caused by experimental effects, and subsequently select an appropriate measurement modality for tablet content uniformity determination with near-infrared (NIR) spectroscopy. Two NIR spectrometers furnished with three configurations in the sample measurement interface were evaluated. One spectrometer, Bruker MPA (multiple purpose analyzer), was equipped with two measurement modalities, diffuse transmission (DT) and diffuse reflection based on integrating sphere optics (DR/IS). The other spectrometer, Bruker StepOne, was equipped only with diffuse reflection mode based on a fiber-optic probe (DR/FO). The data were collected with each of the configurations for the tablets associated with two dosage strengths differing significantly in diameter and thickness. Spectral diagnosis was performed in terms of sensitivity and selectivity. The signal-to-noise ratio computed for the data collected with the DT and DR/IS spectrometers was approximately an order of magnitude greater than that computed for the DR/FO spectrometer. The net-analyte-signal-based selectivity analysis of NIR spectra associated with the sample tablet and the placebo tablet indicated that both transmission and reflection mode provided similar selectivity when the optimal spectral range was chosen. A partial least squares (PLS) calibration model was developed for each data set. The overall standard error of calibration for each DT and DR/IS measurement was approximately 0.3% in weight for each strength, significantly better than the value of 1.0% in weight produced by the DR/FO measurement. This result was consistent with the sensitivity analysis based on spectral noise characterization. The poor analytical performance of the DR/FO spectrometer was attributed to the small illumination spot size of the reflection probe and thus the sensitivity of the measurements to the tablet engraving. The PLS analysis and spectral diagnostics both showed that transmission and reflection modes based on the Bruker MPA provided similar measurement accuracy for each strength. However, the robustness study clearly revealed that the transmission mode would be more robust than the reflection mode when there is considerable variability in the chemical composition and physical properties of tablets.


Assuntos
Preparações Farmacêuticas/análise , Espectroscopia de Luz Próxima ao Infravermelho , Comprimidos/química , Algoritmos , Calibragem , Cromatografia Líquida de Alta Pressão , Processamento de Imagem Assistida por Computador , Análise dos Mínimos Quadrados , Análise Multivariada , Óptica e Fotônica , Análise de Regressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação
9.
J Pharm Biomed Anal ; 49(1): 48-54, 2009 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-19027256

RESUMO

A robust, noninvasive, real-time, on-line near-infrared (NIR) quantitative method is described for blend uniformity monitoring of a pharmaceutical solid dosage form containing 29.4% (w/w) drug load with three major excipients (crospovidone, lactose, and microcrystalline cellulose). A set of 21 off-line, static calibration samples were used to develop a multivariate partial least-squares (PLS) calibration model for on-line prediction of the API content during the blending process. The concentrations of the API and the three major excipients were varied randomly to minimize correlations between the components. A micro electrical-mechanical system (MEMS) based portable, battery operated NIR spectrometer was used for this study. To minimize spectral differences between the static and dynamic measurement modes, the acquired NIR spectra were preprocessed using standard normal variate (SNV) followed by second derivative Savitzky-Golay using 21 points. The performance of the off-line PLS calibration model were evaluated in real-time on 16 laboratory scale (30 L bin size) blend experiments conducted over 3 months. To challenge the robustness of the off-line calibration model, several blend experiments were conducted using a different bin size, faster revolution speed and variations in the potency of the API. Employing the PLS calibration model developed using the off-line calibration approach, the real-time API NIR (%) predictions for all experiments were all within 90-110%. These results were confirmed using the conventional thief sampling of the final blend followed by high performance liquid chromatography (HPLC) analysis. Further confirmation was established through content uniformity by HPLC of manufactured tablets. Finally, the optimized off-line PLS method was successfully transferred to a production site which involved using a secondary NIR instrument with a 15-fold scale-up in bin size from development.


Assuntos
Preparações Farmacêuticas/química , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Calibragem , Formas de Dosagem , Composição de Medicamentos , Excipientes , Análise dos Mínimos Quadrados , Fatores de Tempo
10.
J Pharm Sci ; 98(3): 1155-66, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18702120

RESUMO

Quantification analysis with near-infrared (NIR) spectroscopy typically requires utilizing chemometric techniques, such as partial least squares (PLS) method, to achieve the desired selectivity. This article points out a major limitation of these statistical-based calibration methods. The limitation is that the techniques suffer from the potential for chance correlation. In this article, the impact of chance correlation on the robustness of PLS model was illustrated via a pharmaceutical application with NIR to the content uniformity determination of tablets. The procedure involves evaluating the PLS models generated with two sets of calibration tablets incorporated with distinct degree of concentration correlation between the active pharmaceutical ingredient (API) and excipients. The selectivity and robustness of the two models were examined by using a series of data sets associated with placebo tablets and tablets incorporated with variations from excipient content, hardness and particle size. The result clearly revealed that the strong correlation observed in the PLS model created by the correlated design was not solely based on the API information, and there was an intrinsic difference in the variances described by the two calibration models. Diagnostic tools that enable the characterization of the chemical selectivity of the calibration model were also proposed for pharmaceutical quantitative analysis.


Assuntos
Espectroscopia de Luz Próxima ao Infravermelho/métodos , Comprimidos/química , Calibragem , Testes de Dureza , Análise dos Mínimos Quadrados , Modelos Teóricos , Análise Multivariada , Reprodutibilidade dos Testes
11.
Drug Dev Ind Pharm ; 34(10): 1022-35, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18777445

RESUMO

This article aimed to model the effects of raw material properties and roller compactor operating parameters (OPs) on the properties of roller compacted ribbons and granules with the aid of principal component analysis (PCA) and partial least squares (PLS) projection. A database of raw material properties was established through extensive physical and mechanical characterization of several microcrystalline cellulose (MCC) and lactose grades and their blends. A design of experiment (DoE) was used for ribbon production. PLS models constructed with only OP-modeled roller compaction (RC) responded poorly. Inclusion of raw material properties markedly improved the goodness of fit (R(2) = .897) and model predictability (Q(2) = 0.72).


Assuntos
Comprimidos , Tecnologia Farmacêutica , Celulose , Excipientes , Lactose , Análise dos Mínimos Quadrados , Análise Multivariada , Análise de Componente Principal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...