Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 37(7): 3725-37, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20831080

RESUMO

PURPOSE: The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is to introduce the concept of three dimensional (3D) intensity modulated brachytherapy and solve two fundamental issues regarding the application of 3D IMBT treatment planning: The dose calculation algorithm and the inverse treatment planning method. METHODS: A 3D IMBT treatment planning system prototype was developed using the MATLAB platform. This system consists of three major components: (1) A comprehensive IMBT source calibration method with dosimetric inputs from Monte Carlo (EGSnrc) simulations; (2) a "modified TG-43" (mTG-43) dose calculation formalism for IMBT dosimetry; and (3) a physical constraint based inverse IMBT treatment planning platform utilizing a simulated annealing optimization algorithm. The model S700 Axxent electronic brachytherapy source developed by Xoft, Inc. (Fremont, CA), was simulated in this application. Ten intracavitary accelerated partial breast irradiation (APBI) cases were studied. For each case, an "isotropic plan" with only optimized source dwell time and a fully optimized IMBT plan were generated and compared to the original plan in various dosimetric aspects, such as the plan quality, planning, and delivery time. The issue of the mechanical complexity of the IMBT applicator is not addressed in this study. RESULTS: IMBT approaches showed superior plan quality compared to the original plans and tht isotropic plans to different extents in all studied cases. An extremely difficult case with a small breast and a small distance to the ribs and skin, the IMBT plan minimized the high dose volume V200 by 16.1% and 4.8%, respectively, compared to the original and the isotropic plans. The conformity index for the target was increased by 0.13 and 0.04, respectively. The maximum dose to the skin was reduced by 56 and 28 cGy, respectively, per fraction. Also, the maximum dose to the ribs was reduced by 104 and 96 cGy, respectively, per fraction. The mean dose to the ipsilateral and contralateral breasts and lungs were also slightly reduced by the IMBT plan. The limitations of IMBT are the longer planning and delivery time. The IMBT plan took around 2 h to optimize, while the isotropic plan optimization could reach the global minimum within 5 min. The delivery time for the IMBT plan is typically four to six times longer than the corresponding isotropic plan. CONCLUSIONS: In this study, a dosimetry method for IMBT sources was proposed and an inverse treatment planning system prototype for IMBT was developed. The improvement of plan quality by 3D IMBT was demonstrated using ten APBI case studies. Faster computers and higher output of the source can further reduce plan optimization and delivery time, respectively.


Assuntos
Algoritmos , Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Benchmarking , Estudos de Viabilidade , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
2.
Phys Med Biol ; 55(18): 5283-97, 2010 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-20720283

RESUMO

A low-energy electronic brachytherapy source (EBS), the model S700 Axxent x-ray device developed by Xoft Inc., has been used in high dose rate (HDR) intracavitary accelerated partial breast irradiation (APBI) as an alternative to an Ir-192 source. The prescription dose and delivery schema of the electronic brachytherapy APBI plan are the same as the Ir-192 plan. However, due to its lower mean energy than the Ir-192 source, an EBS plan has dosimetric and biological features different from an Ir-192 source plan. Current brachytherapy treatment planning methods may have large errors in treatment outcome prediction for an EBS plan. Two main factors contribute to the errors: the dosimetric influence of tissue heterogeneities and the enhancement of relative biological effectiveness (RBE) of electronic brachytherapy. This study quantified the effects of these two factors and revisited the plan quality of electronic brachytherapy APBI. The influence of tissue heterogeneities is studied by a Monte Carlo method and heterogeneous 'virtual patient' phantoms created from CT images and structure contours; the effect of RBE enhancement in the treatment outcome was estimated by biologically effective dose (BED) distribution. Ten electronic brachytherapy APBI cases were studied. The results showed that, for electronic brachytherapy cases, tissue heterogeneities and patient boundary effect decreased dose to the target and skin but increased dose to the bones. On average, the target dose coverage PTV V(100) reduced from 95.0% in water phantoms (planned) to only 66.7% in virtual patient phantoms (actual). The actual maximum dose to the ribs is 3.3 times higher than the planned dose; the actual mean dose to the ipsilateral breast and maximum dose to the skin were reduced by 22% and 17%, respectively. Combining the effect of tissue heterogeneities and RBE enhancement, BED coverage of the target was 89.9% in virtual patient phantoms with RBE enhancement (actual BED) as compared to 95.2% in water phantoms without RBE enhancement (planned BED). About 10% increase in the source output is required to raise BED PTV V(100) to 95%. As a conclusion, the composite effect of dose reduction in the target due to heterogeneities and RBE enhancement results in a net effect of 5.3% target BED coverage loss for electronic brachytherapy. Therefore, it is suggested that about 10% increase in the source output may be necessary to achieve sufficient target coverage higher than 95%.


Assuntos
Artefatos , Braquiterapia/métodos , Mama/patologia , Mama/efeitos da radiação , Elétrons , Doses de Radiação , Benchmarking , Humanos , Radioisótopos de Irídio/uso terapêutico , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica
3.
Phys Med Biol ; 54(18): 5595-611, 2009 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-19717887

RESUMO

This work investigates variation in the volume of the prostate measured at different stages through the prostate brachytherapy procedure for 30 patients treated with I-125 radioactive seeds. The implanted seeds were localized on post-implantation ultrasound (US) images and the effect of prostate enlargement due to edema on dose coverage for 15 patients was studied. The volume of the prostate was measured at four stages as follows: (a) 2-3 weeks prior to implantation using US imaging, (b) then at the start of the intra-operative prostate brachytherapy procedure on the day of the implant, (c) immediately post-implantation using US imaging in the operating room and (d) finally by CT imaging at nearly 4 weeks post-implantation. Comparative prostate volume studies were performed using US imaging stepper and twister modes. For the purpose of this study, the implanted seeds were localized successfully on post-implant ultrasound twister images, retrospectively. The plans using post-implant US imaging were compared with intra-operative plans on US and plans created on CT images. The prostate volume increases about 10 cm(3) on average due to edema induced by needle insertion and seed loading during implantation. The visibility of the implanted seeds on US twister images acquired post-implantation is as good as those on CT images and can be localized and used for dose calculation. The dose coverage represented by parameters such as D90 (dose covering 90% of the volume) and V100 (volume covered by 100% dose) is poorer on plans performed on post-implantation twister US studies than on the intra-operative live plan or the CT scan performed 4 weeks post-operatively. For example, the mean D90 difference on post-implantation US is lower by more than 15% than that on pre-implantation US. The volume enlargement of the prostate due to edema induced by needle insertion and seed placement has a significant effect on the quality of dosimetric coverage in brachytherapy prostate seed implants. Here, we introduced a new approach based on the use of post-implant US twister images to correct for prostate enlargement intra-operatively. Besides the ability to localize the seeds and superior soft tissue visibility, the twister US images include effects of the enlargement of the prostate gland and seed migration during the implantation procedure.


Assuntos
Braquiterapia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/radioterapia , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Braquiterapia/instrumentação , Humanos , Masculino , Prognóstico , Próteses e Implantes , Implantação de Prótese , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
4.
J Chin Med Assoc ; 69(10): 484-8, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17098673

RESUMO

BACKGROUND: Menstrual pain can be alleviated after childbirth. The purpose of this observational study was to evaluate the natural progression of menstrual pain among nulliparous women at their reproductive age. METHODS: A questionnaire-based study of perimenopausal women with a history of primary dysmenorrhea was performed. The study subjects were recruited between July 1, 2001 and June 30, 2005. Severity of menstrual pain was graded using a multidimensional scoring system. RESULTS: A total of 247 nulliparous women with primary dysmenorrhea were enrolled, and of these, 218 patients were eligible for analysis. Patients who had more frequent intercourse (p = 0.016), fewer associated systemic symptoms (p = 0.028), and use of oral contraceptive pills (p = 0.039) tended to have a higher chance of an improvement in dysmenorrhea after age 40. Multidimensional scoring distribution over chronologic age revealed that patients had significantly improved menstrual pain after 40 years of age. CONCLUSION: For nulliparous women with primary dysmenorrhea, the severity of menstrual pain decreased significantly after age 40. More studies are needed to explore this phenomenon from a biochemical or molecular basis.


Assuntos
Dismenorreia/fisiopatologia , Fatores Etários , Anticoncepcionais Orais/farmacologia , Progressão da Doença , Feminino , Humanos , Pessoa de Meia-Idade , Reprodução , Comportamento Sexual
5.
J Chin Med Assoc ; 69(3): 110-4, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16599015

RESUMO

BACKGROUND: This pilot study was undertaken to evaluate the effect of laparoscopic uterosacral nerve ablation (LUNA) for treatment of primary deep dyspareunia. METHODS: Between July 2002 and June 2003, 12 consecutive patients diagnosed with primary deep dyspareunia were treated with the LUNA procedure. The evaluation scoring system included the Hospital Anxiety and Depression Scale and the revised Sabbatsberg Sexual Rating Scale, done at baseline and 3, 6, and 12 months after LUNA. RESULTS: At the initial 3-month follow-up period, 3 patients were very satisfied with their treatment, 5 were satisfied, 2 uncertain, 1 dissatisfied, and 1 very dissatisfied. The corresponding figures at the 12-month follow-up visit were 2, 4, 4, 1, and 1, respectively. Overall, 8 (66.7%) patients in this trial were very satisfied or satisfied at the initial postoperative evaluation and 6 of them (50.0%) remained satisfied at the final evaluation. CONCLUSION: Over half of the study patients felt satisfied with the results of treatment with LUNA. Further prospective controlled clinical trials are mandatory to validate its effectiveness.


Assuntos
Ablação por Cateter/métodos , Dispareunia/cirurgia , Laparoscopia/métodos , Sacro/inervação , Útero/inervação , Feminino , Humanos , Projetos Piloto , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...