Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Exp Ophthalmol ; 39(3): 215-21, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21070544

RESUMO

BACKGROUND: To investigate and compare the effect of cataract and pupil size on retinal nerve fibre layer (RNFL) thickness measurements using spectral-domain optical coherence tomography (Cirrus OCT) and time-domain OCT (Stratus OCT). DESIGN: Prospective, hospital-based study. PARTICIPANTS: Twenty-five eyes from 25 normal subjects undergoing cataract surgery. METHODS: Three retinal nerve fibre layer (RNFL) thickness measurements were taken before and after dilation, preoperatively and postoperatively, using Cirrus 200×200 Optic Disc Scan and Stratus Fast RNFL Scan. MAIN OUTCOME MEASURES: Linear regression, intraclass correlation coefficient (ICC) and coefficient of variation analysis. RESULTS: Cataract removal caused significant increase in RNFL measurements in both modalities (Cirrus P<0.02; Stratus P<0.001). There was no significant difference in the increase in measurements between the two machines. Pupil dilation had variable and non-statistically significant effect in both (P>0.05). ICC showed excellent reproducibility with Cirrus OCT after mydriasis, preoperatively (ICC=0.78-0.90) and postoperatively (ICC=0.90-0.97), but poor reproducibility before mydriasis (P<0.75). Stratus OCT achieved excellent reproducibility after cataract removal both before (ICC=0.86-0.96) and after mydriasis (ICC=0.92-0.95), but poor reproducibility before cataract surgery (P<0.75). CONCLUSIONS: Cataracts, not pupil size, cause significant underestimation of RNFL measurements in both Cirrus and Stratus OCT. The extent of influence exerted does not appear different between the two instruments. Reproducibility of each machine appears to be affected differently. Mydriasis is required to achieve excellent reproducibility with Cirrus OCT, and media clarity is required with Stratus OCT.


Assuntos
Catarata/complicações , Fibras Nervosas/patologia , Disco Óptico/patologia , Pupila/fisiologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Prospectivos , Reprodutibilidade dos Testes , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...