Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Diagnostics (Basel) ; 14(3)2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38337845

RESUMO

This study aims explore the feasibility of using neural network (NNs) and deep learning to diagnose three common respiratory diseases with few symptom words. These three diseases are nasopharyngitis, upper respiratory infection, and bronchitis/bronchiolitis. Through natural language processing, the symptom word vectors are encoded by GPT-2 and classified by the last linear layer of the NN. The experimental results are promising, showing that this model achieves a high performance in predicting all three diseases. They revealed 90% accuracy, which suggests the implications of the developed model, highlighting its potential use in assisting patients' understanding of their conditions via a remote diagnosis. Unlike previous studies that have focused on extracting various categories of information from medical records, this study directly extracts sequential features from unstructured text data, reducing the effort required for data pre-processing.

2.
Diagnostics (Basel) ; 13(24)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38132274

RESUMO

Lung cancer (LC) stands as the foremost cause of cancer-related fatality rates worldwide. Early diagnosis significantly enhances patient survival rate. Nowadays, low-dose computed tomography (LDCT) is widely employed on the chest as a tool for large-scale lung cancer screening. Nonetheless, a large amount of chest radiographs creates an onerous burden for radiologists. Some computer-aided diagnostic (CAD) tools can provide insight to the use of medical images for diagnosis and can augment diagnostic speed. However, due to the variation in the parameter settings across different patients, substantial discrepancies in image voxels persist. We found that different voxel sizes can create a compromise between model generalization and diagnostic efficacy. This study investigates the performance disparities of diagnostic models trained on original images and LDCT images reconstructed to different voxel sizes while making isotropic. We examined the ability of our method to differentiate between benign and malignant nodules. Using 11 features, a support vector machine (SVM) was trained on LDCT images using an isotropic voxel with a side length of 1.5 mm for 225 patients in-house. The result yields a favorable model performance with an accuracy of 0.9596 and an area under the receiver operating characteristic curve (ROC/AUC) of 0.9855. In addition, to furnish CAD tools for clinical application, future research including LDCT images from multi-centers is encouraged.

3.
Diagnostics (Basel) ; 13(19)2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37835785

RESUMO

The use of deep learning methods for the automatic detection and quantification of bone metastases in bone scan images holds significant clinical value. A fast and accurate automated system for segmenting bone metastatic lesions can assist clinical physicians in diagnosis. In this study, a small internal dataset comprising 100 breast cancer patients (90 cases of bone metastasis and 10 cases of non-metastasis) and 100 prostate cancer patients (50 cases of bone metastasis and 50 cases of non-metastasis) was used for model training. Initially, all image labels were binary. We used the Otsu thresholding method or negative mining to generate a non-metastasis mask, thereby transforming the image labels into three classes. We adopted the Double U-Net as the baseline model and made modifications to its output activation function. We changed the activation function to SoftMax to accommodate multi-class segmentation. Several methods were used to enhance model performance, including background pre-processing to remove background information, adding negative samples to improve model precision, and using transfer learning to leverage shared features between two datasets, which enhances the model's performance. The performance was investigated via 10-fold cross-validation and computed on a pixel-level scale. The best model we achieved had a precision of 69.96%, a sensitivity of 63.55%, and an F1-score of 66.60%. Compared to the baseline model, this represents an 8.40% improvement in precision, a 0.56% improvement in sensitivity, and a 4.33% improvement in the F1-score. The developed system has the potential to provide pre-diagnostic reports for physicians in final decisions and the calculation of the bone scan index (BSI) with the combination with bone skeleton segmentation.

4.
Diagnostics (Basel) ; 13(13)2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37443695

RESUMO

Bone Scan Index (BSI) is an image biomarker for quantifying bone metastasis of cancers. To compute BSI, not only the hotspots (metastasis) but also the bones have to be segmented. Most related research focus on binary classification in bone scintigraphy: having metastasis or none. Rare studies focus on pixel-wise segmentation. This study compares three advanced convolutional neural network (CNN) based models to explore bone segmentation on a dataset in-house. The best model is Mask R-CNN, which reaches the precision, sensitivity, and F1-score: 0.93, 0.87, 0.90 for prostate cancer patients and 0.92, 0.86, and 0.88 for breast cancer patients, respectively. The results are the average of 10-fold cross-validation, which reveals the reliability of clinical use on bone segmentation.

5.
J Pers Med ; 12(9)2022 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-36143163

RESUMO

The five-year overall survival rate of patients without neck lymph node recurrence is over 50% higher than those with lymph node metastasis. This study aims to investigate the prognostic impact of computed tomogram (CT)-based radiomics on the outcome of metastatic neck lymph nodes in patients with head and neck cancer (HNC) receiving definitive radiotherapy or chemoradiotherapy for organ preservation. The pretreatment 18F-FDG PET/CT of 79 HNC patients was retrospectively analyzed with radiomics extractors. The imbalanced data was processed using two techniques: over-sampling and under-sampling, after which the prediction model was established with a machine learning model using the XGBoost algorithm. The imbalanced dataset strategies slightly decreased the specificity but greatly improved the sensitivity. To have a higher chance of predicting neck cancer recurrence, however, clinical data combined with CT-based radiomics provides the best prediction effect. The original dataset performed was as follows: accuracy = 0.76 ± 0.07, sensitivity = 0.44 ± 0.22, specificity = 0.88 ± 0.06. After we used the over-sampling technique, the accuracy, sensitivity, and specificity values were 0.80 ± 0.05, 0.67 ± 0.11, and 0.84 ± 0.05, respectively. Furthermore, after using the under-sampling technique, the accuracy, sensitivity, and specificity values were 0.71 ± 0.09, 0.73 ± 0.13, and 0.70 ± 0.13, respectively. The outcome of metastatic neck lymph nodes in patients with HNC receiving radiotherapy for organ preservation can be predicted based on the results of machine learning. This way, patients can be treated alternatively. A further external validation study is required to verify our findings.

6.
J Pers Med ; 12(7)2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35887602

RESUMO

BACKGROUND: Cardiovascular management and risk stratification of patients is an important issue in clinics. Patients who have experienced an adverse cardiac event are concerned for their future and want to know the survival probability. METHODS: We trained eight state-of-the-art CNN models using polar maps of myocardial perfusion imaging (MPI), gender, lung/heart ratio, and patient age for 5-year survival prediction after an adverse cardiac event based on a cohort of 862 patients who had experienced adverse cardiac events and stress/rest MPIs. The CNN model outcome is to predict a patient's survival 5 years after a cardiac event, i.e., two classes, either yes or no. RESULTS: The best accuracy of all the CNN prediction models was 0.70 (median value), which resulted from ResNet-50V2, using image as the input in the baseline experiment. All the CNN models had better performance after using frequency spectra as the input. The accuracy increment was about 7~9%. CONCLUSIONS: This is the first trial to use pure rest/stress MPI polar maps and limited clinical data to predict patients' 5-year survival based on CNN models and deep learning. The study shows the feasibility of using frequency spectra rather than images, which might increase the performance of CNNs.

7.
PLoS One ; 17(7): e0270679, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35881581

RESUMO

The kinetics and the conversion features of two 3-component systems (A/B/N), based on the proposed new kinetic schemes of Mokbel and Mau et al, in which a visible LED is used to excite a copper complex to its excited triplet state (G*). The coupling of G* with iodonium salt and ethyl 4-(dimethylamino)benzoate (EDB) produces both free radical polymerization (FRP) of acrylates and the free radical promoted cationic polymerization (CP) of epoxides using various new copper complex as the initiator. Higher FRP and CP conversion can be achieved by co-additive of [B] and N, via the dual function of (i) regeneration [A], and (ii) generation of extra radicals. The interpenetrated polymer network (IPN) capable of initiating both FRP and CP in a blend of TMPTA and EPOX. The synergic effects due to CP include: (i) CP can increase viscosity limiting the diffusional oxygen replenishment; (ii) the cation also acts as a diluting agent for the IPN network, and (iii) the exothermic property of the CP. The catalytic cycle, synergic effects, and the oxygen inhibition are theoretically confirmed to support the experimental hypothesis. The measured results of Mokbel and Mau et al are well analyzed and matching the predicted features of our modeling.


Assuntos
Cobre , Luz , Cátions , Radicais Livres , Oxigênio , Polímeros
8.
Polymers (Basel) ; 14(6)2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35335489

RESUMO

This article presents, for the first time, the efficacy and curing depth analysis of photo-thermal dual polymerization in metal (Fe) polymer composites for 3D printing of a three-component (A/B/M) system based on the proposed mechanism of our group, in which the co initiators A and B are Irgacure-369 and charge-transfer complexes (CTC), respectively, and the monomer M is filled by Fe. Our formulas show the depth of curing (Zc) is an increasing function of the light intensity, but a decreasing function of the Fe and photoinitiator concentrations. Zc is enhanced by the additive [B], which produces extra thermal radical for polymerization under high temperature. The heat (or temperature) increase in the system has two components: (i) due to the light absorption of Fe filler and (ii) heat released from the exothermic photopolymerization of the monomer. The heat is transported to the additive (or co-initiator) [B] to produce extra radicals and enhance the monomer conversion function (CF). The Fe filler leads to a temperature increase but also limits the light penetration, leading to lower CF and Zc, which could be overcome by the additive initiator [B] in thick polymers. Optimal Fe for maximal CF and Zc are explored theoretically. Measured data are analyzed based on our derived formulas.

9.
Diagnostics (Basel) ; 11(3)2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33803921

RESUMO

This study aimed to explore efficient ways to diagnose bone metastasis early using bone scintigraphy images through negative mining, pre-training, the convolutional neural network, and deep learning. We studied 205 prostate cancer patients and 371 breast cancer patients and used bone scintigraphy data from breast cancer patients to pre-train a YOLO v4 with a false-positive reduction strategy. With the pre-trained model, transferred learning was applied to prostate cancer patients to build a model to detect and identify metastasis locations using bone scintigraphy. Ten-fold cross validation was conducted. The mean sensitivity and precision rates for bone metastasis location detection and classification (lesion-based) in the chests of prostate patients were 0.72 ± 0.04 and 0.90 ± 0.04, respectively. The mean sensitivity and specificity rates for bone metastasis classification (patient-based) in the chests of prostate patients were 0.94 ± 0.09 and 0.92 ± 0.09, respectively. The developed system has the potential to provide pre-diagnostic reports to aid in physicians' final decisions.

10.
Sensors (Basel) ; 20(17)2020 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-32858982

RESUMO

In this study, we proposed a semi-automated and interactive scheme for organ contouring in radiotherapy planning for patients with non-small cell lung cancers. Several organs were contoured, including the lungs, airway, heart, spinal cord, body, and gross tumor volume (GTV). We proposed some schemes to automatically generate and vanish the seeds of the random walks (RW) algorithm. We considered 25 lung cancer patients, whose computed tomography (CT) images were obtained from the China Medical University Hospital (CMUH) in Taichung, Taiwan. The manual contours made by clinical oncologists were taken as the gold standard for comparison to evaluate the performance of our proposed method. The Dice coefficient between two contours of the same organ was computed to evaluate the similarity. The average Dice coefficients for the lungs, airway, heart, spinal cord, and body and GTV segmentation were 0.92, 0.84, 0.83, 0.73, 0.85 and 0.66, respectively. The computation time was between 2 to 4 min for a whole CT sequence segmentation. The results showed that our method has the potential to assist oncologists in the process of radiotherapy treatment in the CMUH, and hopefully in other hospitals as well, by saving a tremendous amount of time in contouring.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Planejamento da Radioterapia Assistida por Computador , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Taiwan , Tomografia Computadorizada por Raios X
11.
Front Chem ; 7: 760, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31799237

RESUMO

Kinetic equations for a modeling system with type-I radical-mediated and type-II oxygen-mediated pathways are derived and numerically solved for the photopolymerization efficacy and curing depth, under the quasi-steady state assumption, and bimolecular termination. We show that photopolymerization efficacy is an increasing function of photosensitizer (PS) concentration (C 0) and the light dose at transient state, but it is a decreasing function of the light intensity, scaled by [C 0/I 0]0.5 at steady state. The curing (or cross-link) depth is an increasing function of C 0 and light dose (time × intensity), but it is a decreasing function of the oxygen concentration, viscosity effect, and oxygen external supply rate. Higher intensity results in a faster depletion of PS and oxygen. For optically thick polymers (>100 um), light intensity is an increasing function of time due to PS depletion, which cannot be neglected. With oxygen inhibition effect, the efficacy temporal profile has an induction time defined by the oxygen depletion rate. Efficacy is also an increasing function of the effective rate constant, K = k'/ k T 0 . 5 , defined by the radical producing rate (k') and the bimolecular termination rate (k T). In conclusion, the curing depth has a non-linear dependence on the PS concentration, light intensity, and dose and a decreasing function of the oxygen inhibition effect. Efficacy is scaled by [C 0/I 0]0.5 at steady state. Analytic formulas for the efficacy and curing depth are derived, for the first time, and utilized to analyze the measured pillar height in microfabrication. Finally, various strategies for improved efficacy and curing depth are discussed.

12.
Polymers (Basel) ; 11(11)2019 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-31698682

RESUMO

The kinetics and modeling of dual-wavelength (UV and blue) controlled photopolymerization confinement (PC) are presented and measured data are analyzed by analytic formulas and numerical data. The UV-light initiated inhibition effect is strongly monomer-dependent due to different C=C bond rate constants and conversion efficacies. Without the UV-light, for a given blue-light intensity, higher initiator concentration (C10) and rate constant (k') lead to higher conversion, as also predicted by analytic formulas, in which the total conversion rate (RT) is an increasing function of C1 and k'R, which is proportional to k'[gB1C1]0.5. However, the coupling factor B1 plays a different role that higher B1 leads to higher conversion only in the transient regime; whereas higher B1 leads to lower steady-state conversion. For a fixed initiator concentration C10, higher inhibitor concentration (C20) leads to lower conversion due to a stronger inhibition effect. However, same conversion reduction was found for the same H-factor defined by H0 = [b1C10 - b2C20]. Conversion of blue-only are much higher than that of UV-only and UV-blue combined, in which high C20 results a strong reduction of blue-only-conversion, such that the UV-light serves as the turn-off (trigger) mechanism for the purpose of spatial confirmation within the overlap area of UV and blue light. For example, UV-light controlled methacrylate conversion of a glycidyl dimethacrylate resin is formulated with a tertiary amine co-initiator, and butyl nitrite. The system is subject to a continuous exposure of a blue light, but an on-off exposure of a UV-light. Finally, we developed a theoretical new finding for the criterion of a good material/candidate governed by a double ratio of light-intensity and concentration, [I20C20]/[I10C10].

13.
Polymers (Basel) ; 11(10)2019 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-31658683

RESUMO

Kinetics and analytical formulas for radical-mediated thiol-ene photopolymerization were developed in this paper. The conversion efficacy of thiol-ene systems was studied for various propagation to chain transfer kinetic rate-ratio (RK), and thiol-ene concentration molar-ratio (RC). Numerical data were analyzed using analytical formulas and compared with the experimental data. We demonstrated that our model for a thiol-acrylate system with homopolymerization effects, and for a thiol-norbornene system with viscosity effects, fit much better with the measured data than a previous model excluding these effects. The general features for the roles of RK and RC on the conversion efficacy of thiol (CT) and ene (CV) are: (i) for RK = 1, CV and CT have the same temporal profiles, but have a reversed dependence on RC; (ii) for RK >> 1, CT are almost independent of RC; (iii) for RK << 1, CV and CT have the same profiles and both are decreasing functions of the homopolymerization effects defined by kCV; (iv) viscosity does not affect the efficacy in the case of RK >> 1, but reduces the efficacy of CV for other values of RK. For a fixed light dose, higher light intensity has a higher transient efficacy but a lower steady-state conversion, resulting from a bimolecular termination. In contrast, in type II unimolecular termination, the conversion is mainly governed by the light dose rather than its intensity. For optically thick polymers, the light intensity increases with time due to photoinitiator depletion, and thus the assumption of constant photoinitiator concentration (as in most previous models) suffers an error of 5% to 20% (underestimated) of the crosslink depth and the efficacy. Scaling law for the overall reaction order, defined by [A]m[B]n and governed by the types of ene and the rate ratio is discussed herein. The dual ratio (RK and RC) for various binary functional groups (thiol-vinyl, thiol-acrylate, and thiol-norbornene) may be tailored to minimize side effects for maximal monomer conversion or tunable degree of crosslinking.

14.
Polymers (Basel) ; 11(2)2019 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-30960200

RESUMO

Optimal conditions for maximum efficacy of photoinitiated polymerization are theoretically presented. Analytic formulas are shown for the crosslink time, crosslink depth, and efficacy function. The roles of photoinitiator (PI) concentration, diffusion depth, and light intensity on the polymerization spatial and temporal profiles are presented for both uniform and non-uniform cases. For the type I mechanism, higher intensity may accelerate the polymer action process, but it suffers a lower steady-state efficacy. This may be overcome by a controlled re-supply of PI concentration during the light exposure. In challenging the conventional Beer⁻Lambert law (BLL), a generalized, time-dependent BLL (a Lin-law) is derived. This study, for the first time, presents analytic formulas for curing depth and crosslink time without the assumption of thin-film or spatial average. Various optimal conditions are developed for maximum efficacy based on a numerically-fit A-factor. Experimental data are analyzed for the role of PI concentration and light intensity on the gelation (crosslink) time and efficacy.

15.
Sensors (Basel) ; 18(9)2018 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-30208616

RESUMO

Cardiac stroke volume (SV) is an essential hemodynamic indicator that can be used to assess whether the pump function of the heart is normal. Non-invasive SV measurement is currently performed using the impedance cardiography (ICG). In this technology, left ventricular ejection time (LVET) is an important parameter which can be determined from the ICG signals. However, the ICG signals are inherently susceptible to artificial noise interference, which leads to an inaccurate LVET measurement and then yields an error in the calculation of SV. Therefore, the goal of the study was to measure LVETs using both the transmission and reflection photoplethysmography (PPG), and to assess whether the measured LVET was more accurate by the PPG signal than the ICG signal. The LVET measured by the phonocardiography (PCG) was used as the standard for comparing with those by the ICG and PPG. The study recruited ten subjects whose LVETs were simultaneously measured by the ICG using four electrodes, the reflection PPG using neck sensors (PPGneck) and the transmission PPG using finger sensors (PPGfinger). In each subject, ten LVETs were obtained from ten heartbeats selected properly from one-minute recording. The differences of the measured LVETs between the PCG and one of the ICG, PPGneck and PPGfinger were -68.2 ± 148.6 ms, 4.8 ± 86.5 ms and -7.0 ± 107.5 ms, respectively. As compared with the PCG, both the ICG and PPGfinger underestimated but the PPGneck overestimated the LVETs. Furthermore, the measured LVET by the PPGneck was the closest to that by the PCG. Therefore, the PPGneck may be employed to improve the LVET measurement in applying the ICG for continuous monitoring of SV in clinical settings.


Assuntos
Cardiografia de Impedância , Fotopletismografia , Volume Sistólico , Adulto , Humanos , Masculino , Fonocardiografia
16.
J Magn Reson Imaging ; 48(5): 1255-1263, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29437266

RESUMO

BACKGROUND: Spontaneous intracranial hypotension (SIH) is often misdiagnosed, and can lead to severe complications. Conventional MR sequences show a limited ability to aid in this diagnosis. MR-based intracranial pressure (MR-ICP) may be able to detect changes of intracranial elastance and pressure. PURPOSE: To determine whether MR-ICP is able to differentiate SIH patients from normal subjects, improve diagnostic sensitivity, and provide an insight into the pathophysiology. STUDY TYPE: Prospective. SUBJECTS: Twenty-eight SIH cases with orthostatic headache and 20 healthy volunteers. FIELD STRENGTH/SEQUENCE: Cine phase-contrast MRI on a 1.5T scanner. ASSESSMENT: Intracranial elastance (IE) was derived from the ratio of the peak-to-peak cerebrospinal fluid (CSF) pressure gradient (PGcsf-pp ) and intracranial volume change, obtained by summing all flows before each sequential cardiac frame. STATISTICAL TESTS: Student's t-test was used to compare the MR-ICP indexes and flow parameters between SIH patients and healthy volunteers (P < 0.01). RESULTS: The SIH patients with cervical epidural venous dilatation (EVD) had an IE of 0.121 ± 0.027 mmHg/cm/ml, significantly higher than that of the normal volunteers (0.085 ± 0.027 mmHg/cm/ml; P = 0.002). In contradistinction, the EVD-negative SIH patients, including four with no sign of CSF leaks, had significantly lower IE (0.055 ± 0.012 mmHg/cm/ml) compared with the normal volunteers and the EVD-positive group (P = 0.001, P < 0.001). The EVD-negative patients had significantly lower PGcsf-pp (0.024 ± 0.007 mmHg/cm) compared with the normal volunteers and the EVD-positive group (0.035 ± 0.011 mmHg/cm, 0.040 ± 0.010 mmHg/cm; P = 0.003, P < 0.001). Additionally, the MRI flow study showed a significant decrease in transcranial inflow and outflow of SIH patients (P < 0.01). DATA CONCLUSION: We found that the MR-ICP method is potentially more sensitive than morphological MRI in the early diagnosis of SIH. Also, contrary to common belief, our results suggest that an abnormal craniospinal elastance might be the cause of SIH, instead of CSF leak. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1255-1263.


Assuntos
Cefaleia/diagnóstico por imagem , Hipotensão Intracraniana/diagnóstico por imagem , Pressão Intracraniana , Imagem Cinética por Ressonância Magnética , Adulto , Encéfalo/diagnóstico por imagem , Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Processamento de Sinais Assistido por Computador , Coluna Vertebral/diagnóstico por imagem
17.
Sci Rep ; 7(1): 15108, 2017 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-29118335

RESUMO

Lung cancer has a very high prevalence of brain metastasis, which results in a poor clinical outcome. Up-regulation of a disintegrin and metalloproteinase 9 (ADAM9) in lung cancer cells is correlated with metastasis to the brain. However, the molecular mechanism underlying this correlation remains to be elucidated. Since angiogenesis is an essential step for brain metastasis, microarray experiments were used to explore ADAM9-regulated genes that function in vascular remodeling. The results showed that the expression levels of vascular endothelial growth factor A (VEGFA), angiopoietin-2 (ANGPT2), and tissue plasminogen activator (PLAT) were suppressed in ADAM9-silenced cells, which in turn leads to decreases in angiogenesis, vascular remodeling, and tumor growth in vivo. Furthermore, simultaneous high expression of ADAM9 and VEGFA or of ADAM9 and ANGPT2 was correlated with poor prognosis in a clinical dataset. These findings suggest that ADAM9 promotes tumorigenesis through vascular remodeling, particularly by increasing the function of VEGFA, ANGPT2, and PLAT.


Assuntos
Proteínas ADAM/genética , Angiopoietina-2/genética , Neoplasias Pulmonares/genética , Proteínas de Membrana/genética , Ativador de Plasminogênio Tecidual/genética , Fator A de Crescimento do Endotélio Vascular/genética , Remodelação Vascular/genética , Células A549 , Proteínas ADAM/metabolismo , Angiopoietina-2/metabolismo , Animais , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/secundário , Linhagem Celular , Linhagem Celular Tumoral , Células Cultivadas , Perfilação da Expressão Gênica/métodos , Regulação Neoplásica da Expressão Gênica , Técnicas de Inativação de Genes , Humanos , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/patologia , Proteínas de Membrana/metabolismo , Camundongos Endogâmicos C57BL , Neovascularização Patológica/genética , Neovascularização Patológica/metabolismo , Ativador de Plasminogênio Tecidual/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo
18.
Sensors (Basel) ; 17(5)2017 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-28531140

RESUMO

In the last decade, cuffless blood pressure measurement technology has been widely studied because it could be applied to a wearable apparatus. Electrocardiography (ECG), photo-plethysmography (PPG), and phonocardiography are always used to detect the pulse transit time (PTT) because the changed tendencies of the PTT and blood pressure have a negative relationship. In this study, the PPG signal was replaced by the impedance plethysmography (IPG) signal and was used to detect the PTT. The placement and direction of the electrode array for the IPG measurement were discussed. Then, we designed an IPG ring that could measure an accurate IPG signal. Twenty healthy subjects participated in this study. The changes in blood pressure after exercise were evaluated through the changes of the PTT. The results showed that the change of the systolic pressure had a better relationship with the change of the PTTIPG than that of the PTTPPG (r = 0.700 vs. r = 0.450). Moreover, the IPG ring with spot electrodes would be more suitable to develop with the wearable cuffless blood pressure monitor than the PPG sensor.


Assuntos
Pressão Sanguínea , Determinação da Pressão Arterial , Humanos , Fotopletismografia , Pletismografia de Impedância , Análise de Onda de Pulso
19.
PLoS One ; 12(4): e0175002, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28384251

RESUMO

OBJECTIVE: Analysis of the crosslink time, depth and efficacy profiles of UV-light-activated corneal collagen crosslinking (CXL). METHODS: A modeling system described by a coupled dynamic equations are numerically solved and analytic formulas are derived for the crosslinking time (T*) and crosslinking depth (z*). The z-dependence of the CXL efficacy is numerically produced to show the factors characterizing the profiles. RESULTS: Optimal crosslink depth (z*) and maximal CXL efficacy (Ceff) have opposite trend with respective to the UV light intensity and RF concentration, where z* is a decreasing function of the riboflavin concentration (C0). In comparison, Ceff is an increasing function of C0 and the UV exposure time (for a fixed UV dose), but it is a decreasing function of the UV light intensity. CXL efficacy is a nonlinear increasing function of [C0/I0]-0.5 and more accurate than that of the linear theory of Bunsen Roscoe law. Depending on the UV exposure time and depth, the optimal intensity ranges from 3 to 30 mW/cm2 for maximal CXL efficacy. For steady state (with long exposure time), low intensity always achieves high efficacy than that of high intensity, when same dose is applied on the cornea. CONCLUSIONS: The crosslinking depth (z*) and the crosslinking time (T*) have nonlinear dependence on the UV light dose and the efficacy of corneal collagen crosslinking should be characterized by both z* and the efficacy profiles. A nonlinear scaling law is needed for more accurate protocol.


Assuntos
Colágeno/metabolismo , Córnea/efeitos da radiação , Raios Ultravioleta , Córnea/metabolismo , Modelos Químicos
20.
Biomed Tech (Berl) ; 62(6): 575-580, 2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-27861137

RESUMO

BACKGROUND: A dentist always checks a patient by using panoramic radiography (PR) initially. The measurement of the minimal distance (MD) between the alveolar crest and the mandibular canal (MC) superior border is critically important before the dental implant surgery, extraction of 3rd molar teeth or any surgery in the posterior area of minimal distance (MD). However, the image of MC is not always clear to identify. OBJECTIVE: A software is needed for training dentists as well as a tool of demonstration to patients in clinics precisely and quickly. Moreover, it should be able to calculate the MD between the alveolar crest and the MC superior border before dental implant. METHODS: A computer-aided software system to semi-automatically detect the MC and mental foramen (MF) in the PR with minimal human interference is proposed. RESULTS: The result shows that the averaged relative error (RE) is 1.83% with a standard deviation of 2.31%. CONCLUSION: The results show that the proposed algorithm is able to detect the MC superior and inferior borders. This system has the potential to train young clinicians and to replace the manual work in measuring the MD between the alveolar crest and the MC superior border with a minimal human intervention.


Assuntos
Processo Alveolar/fisiologia , Mandíbula/fisiologia , Dente Molar/fisiologia , Radiografia Panorâmica/métodos , Implantes Dentários , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...