Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Oncol ; 14: 1366079, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38939341

RESUMO

Objective: To investigate the feasibility of leg wound closure and reconstruction of maxillofacial soft defect by a fusiform-designed skin paddle in fibula free flap (FFF). Methods: Fifty patients who underwent FFF for reconstruction of maxillofacial soft defect were divided into two groups. The fusiform group (20 patients) was treated using a fusiform-designed skin paddle in FFF (skin paddle width less than 2 cm), and leg wound was closed using primary suturing. Reconstruction of the maxillofacial soft defect or filling of dead space was achieved by folding the fusiform skin paddle. The conventional group (30 patients) was treated using the conventional-designed skin paddle (skin paddle width no less than 2.5 cm). The leg wound was closed using mattress suturing or skin graft, while reconstruction of the maxillofacial soft defect or filling of dead space by conventional way. The average postoperative length of hospital stay, healing time of leg wound, and post-surgical complications were recorded at least 6 months after the surgery. Results: Compared with traditional method, the fusiform-designed skin paddle reduced the average healing time of the leg wound (fusiform group: 11.05 days, conventional group: 14.77 days, P < 0.05). The average length-to-width ratio in fusiform group was significantly greater than that of in conventional group (fusiform group: 5.85, conventional group: 2.93, P < 0.05), and no difference was observed on the graft size of skin paddle between two groups (fusiform group: 23.13, conventional group: 27.13, P > 0.05). The post-surgical early complications of the leg wound in the conventional group were higher than that of in the fusiform group (fusiform group: 0%, conventional group: 6.67%), while the post-surgical late complication of the donor site between the two groups showed no case. Healing disorders of maxillofacial soft reconstruction in the conventional group were higher than that of in the fusiform group (fusiform group: 5.26%, conventional group: 20.69%). Conclusions: Fusiform-designed skin paddle for closure of the leg wound and maxillofacial soft defect is a feasible alternative to the conventional- designed skin paddle. The fusiform- designed skin paddle resulted in the less postoperative length of hospital stay, shorter healing time of leg wound and less complication.

2.
Rev Sci Instrum ; 81(4): 043105, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20441323

RESUMO

A cavity ring-down (CRD) spectrometer is built with a continuous-wave Ti:sapphire ring laser. Using a pair of R approximately 0.999 95 high-reflective mirrors, the noise-equivalent minimum detectable absorption loss reaches 7 x 10(-11)/cm over the spectral range of 780-830 nm. A thermal-stabilized Fabry-Perot interferometer is applied to calibrate the CRD spectrum with an accuracy of 1 x 10(-4) cm(-1). The quantitative measurement is carried out for the line profile measurements of some overtone absorption lines of C(2)H(2) near 787 nm. Doppler determined line shape has been observed with milli-Torr acetylene gas in the ring-down cavity. The instrumental line width is estimated from the line profile fitting to be <1 x 10(-4) cm(-1). It demonstrates that the CRD spectrometer with extremely high sensitivity is also very suitable for quantitative measurements including precise line profile studies in the near-infrared.

3.
Rev Sci Instrum ; 79(12): 123101, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19123539

RESUMO

A midinfrared laser spectrometer is built up based on the difference frequency generation (DFG) of a Nd:YAG (yttrium aluminum garnet) laser and a tunable Ti:sapphire (Ti:Sa) laser. Tuning the Ti:Sa laser and operating properly with the periodically poled lithium niobate crystal, the DFG emission is tunable in the spectral range of 2.3-5.0 microm. The 1064 nm Nd:YAG laser frequency is stabilized to the 10(-6) cm(-1) level on a Doppler-broadened I(2) absorption line at 532 nm. As a result, the DFG emission frequency is stabilized within 1x10(-4) cm(-1). The measurement of an absorption line of CH(4) near 3 mum demonstrates that the DFG spectrometer is very suitable for the molecular absorption line profile studies in the midinfrared region.

4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 25(8): 1221-6, 2005 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-16329485

RESUMO

The data of line intensities of the fundamental and low overtone absorption bands of phosphine are the basic reference data for the applications in quantative analysis and astronomy. The method of high-resolution Fourier-transform spectroscopy study on the absorption line intensities is discussed. With a series of measurement and fitting the line profiles, altogether 1760 absorption lines intensities of phosphine were obtained, corresponding to five bands in the 1950-2480 cm(-1) region and four bands in the 3 280-3 580 cm(-1) region. The accuracy of the line intensities was estimated to be +/-6%.


Assuntos
Fosfinas/análise , Espectroscopia de Infravermelho com Transformada de Fourier , Absorção , Algoritmos , Fosfinas/química , Reprodutibilidade dos Testes , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...