Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanoscale Res Lett ; 9(1): 502, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25288911

RESUMO

In this paper, indium (In) films were deposited on glass substrates using DC sputtering method. Multiwalled carbon nanotubes (MWCNTs) and dispersant were dissolved in alcohol, and the mixed solution was deposited on the In films using the spray method. The bi-layer MWCNTs-In2O3 films were annealed at different temperatures (from room temperature to 500°C) in O2 atmosphere. The influences of annealing temperature on the characteristics of the bi-layer MWCNTs-In2O3 films were investigated by scanning electron microscopy, X-ray diffraction pattern, Fourier transform infrared (FT-IR) spectroscopy, and Raman spectroscopy. A separative extended-gate field-effect transistor (EGFET) device combined with a bi-layer MWCNTs-In2O3 film was constructed as a pH sensor. The influences of different annealing temperatures on the performances of the EGFET-based pH sensors were investigated. We would show that the pH sensitivity was dependent on the thermal oxygenation temperature of the bi-layer MWCNTs-In2O3 films.

2.
Circ J ; 73(7): 1356-8, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19122302

RESUMO

Percutaneous coronary intervention (PCI) is the preferred treatment modality for patients with acute coronary syndrome, but the "no-reflow" phenomenon, primarily caused by distal embolism, has hampered the effectiveness of PCI as regards reperfusion of the myocardium. Thrombus aspiration is sometimes used to reduce the incidence of distal embolism, but potentially the procedure may be complicated by upstream thrombus migration and systemic embolism. Two cases of systemic embolism during thrombus aspiration are presented. One patient had embolism of the cerebral artery and the other embolism of the left radial artery. It is suggested that a large-lumen guiding catheter with a deep-seated position and gentle injection of contrast medium should be used for thrombus aspiration.


Assuntos
Artérias Cerebrais , Trombose Coronária/terapia , Embolia/complicações , Infarto do Miocárdio/terapia , Artéria Radial , Sucção/efeitos adversos , Trombose/terapia , Idoso , Angioplastia Coronária com Balão , Angiografia Coronária , Trombose Coronária/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Reperfusão Miocárdica , Trombose/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...