Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Tomography ; 10(4): 471-479, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38668394

RESUMO

BACKGROUND: Refractory ascites affects the prognosis and quality of life in patients with liver cirrhosis. Peritoneovenous shunt (PVS) is a treatment procedure of palliative interventional radiology for refractory ascites. Although it is reportedly associated with serious complications (e.g., heart failure, thrombotic disease), the clinical course of PVS has not been thoroughly evaluated. OBJECTIVES: To evaluate the relationship between chronological course and complications after PVS for refractory ascites in liver cirrhosis patients. MATERIALS AND METHODS: This was a retrospective study of 14 patients with refractory ascites associated with decompensated cirrhosis who underwent PVS placement between June 2011 and June 2023. The clinical characteristics, changes in cardiothoracic ratio (CTR), and laboratory data (i.e., brain natriuretic peptide (BNP), D-dimer, platelet) were evaluated. Follow-up CT images in eight patients were also evaluated for ascites and complications. RESULTS: No serious complication associated with the procedure occurred in any case. Transient increases in BNP and D-dimer levels, decreased platelet counts, and the worsening of CTR were observed in the 2 days after PVS; however, they were improved in 7 days in all cases except one. In the follow-up CT, the amount of ascites decreased in all patients, but one patient with a continuous increase in D-dimer 2 and 7 days after PVS had thrombotic disease (renal and splenic infarction). The mean PVS patency was 345.4 days, and the median survival after PVS placement was 474.4 days. CONCLUSIONS: PVS placement for refractory ascites is a technically feasible palliative therapy. The combined evaluation of chronological changes in BNP, D-dimer, platelet count and CTR, and follow-up CT images may be useful for the early prediction of the efficacy and complications of PVS.


Assuntos
Ascite , Cirrose Hepática , Derivação Peritoneovenosa , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Ascite/etiologia , Idoso , Derivação Peritoneovenosa/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Cuidados Paliativos/métodos , Adulto , Produtos de Degradação da Fibrina e do Fibrinogênio/análise
2.
Quant Imaging Med Surg ; 14(4): 2870-2883, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38617144

RESUMO

Background: Despite advancements in coronary computed tomography angiography (CTA), challenges in positive predictive value and specificity remain due to limited spatial resolution. The purpose of this experimental study was to investigate the effect of 2nd generation deep learning-based reconstruction (DLR) on the quantitative and qualitative image quality in coronary CTA. Methods: A vessel model with stepwise non-calcified plaque was scanned using 320-detector CT. Image reconstruction was performed using four techniques: hybrid iterative reconstruction (HIR), model-based iterative reconstruction (MBIR), DLR, and 2nd generation DLR. The luminal peak CT number, contrast-to-noise ratio (CNR), and edge rise slope (ERS) were quantitatively evaluated via profile curve analysis. Two observers qualitatively graded the graininess, lumen sharpness, and overall lumen visibility on the basis of the degree of confidence for the stenosis severity using a five-point scale. Results: The image noise with HIR, MBIR, DLR, and 2nd generation DLR was 23.0, 21.0, 16.9, and 9.5 HU, respectively. The corresponding CNR (25% stenosis) was 15.5, 15.9, 22.1, and 38.3, respectively. The corresponding ERS (25% stenosis) was 203.2, 198.6, 228.9, and 262.4 HU/mm, respectively. Among the four reconstruction methods, the 2nd generation DLR achieved the significantly highest CNR and ERS values. The score of 2nd generation DLR in all evaluation points (graininess, sharpness, and overall lumen visibility) was higher than those of the other methods (overall vessel visibility score, 2.6±0.5, 3.8±0.6, 3.7±0.5, and 4.6±0.5 with HIR, MBIR, DLR, and 2nd generation DLR, respectively). Conclusions: 2nd generation DLR provided better CNR and ERS in coronary CTA than HIR, MBIR, and previous-generation DLR, leading to the highest subjective image quality in the assessment of vessel stenosis.

3.
J Radiol Case Rep ; 10(2): 33-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27200160

RESUMO

Congenital anterior urethrocutaneous fistula and megalourethra are both rare anomalies. These anomalies are commonly associated with other anorectal or genitourinary anomalies and evaluated with voiding cystourethrography. We examined a 34-month-old boy who presented with a fistula at the penoscrotal junction. A voiding cystourethrogram showed a jet of urine coming through the fistula and proximal saccular dilatation of the penile urethra. We present the imaging findings of the first case of an association between a congenital anterior urethrocutaneous fistula at the penoscrotal junction and a proximal penile megalourethra. We also discuss the etiology, management, and differential diagnosis of this entity, and review the literature.


Assuntos
Fístula Cutânea/congênito , Fístula Cutânea/diagnóstico por imagem , Doenças do Pênis/congênito , Uretra/anormalidades , Doenças Uretrais/congênito , Doenças Uretrais/diagnóstico por imagem , Fístula Urinária/congênito , Fístula Urinária/diagnóstico por imagem , Anormalidades Múltiplas/diagnóstico por imagem , Pré-Escolar , Diagnóstico Diferencial , Humanos , Hipospadia/diagnóstico por imagem , Masculino , Doenças do Pênis/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...