Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-843139

RESUMO

Objective: To analyze emergency management measures in large public hospitals during epidemic prevention of corona virus disease 2019 (COVID-19) in order to promote control efficiency and quality of COVID-19 in the emergency room of public hospitals. Methods: A retrospective analysis was made on the amount of emergency visits and management measures of Shanghai Sixth People's Hospital, Shanghai Jiao Tong University from January to February, 2020, including optimizing the process of emergency treatment during epidemic prevention, strengthening the management of key areas such as pre-examination and triage, emergency room, observation room, fluid room and the intensive-care unit and so on, enhancing the management and education of patients, optimizing the deployment model of medical staff, strengthening personal protection and other management measures. Results: During epidemic prevention, there was no missed diagnosis of COVID-19 in the hospital and no nosocomial cross infection in the emergency room. Conclusion: Enhancement of emergency management model in large public hospitals during COVID-19 epidemic prevention can improve the screening of possible patients and triage of patients so as to prevent nosocomial infection.

2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-849799

RESUMO

Objective: To explore the effect of Slit2/ROBO1 protein (Slit2/ROBO1) signaling pathway in high glucose-induced epithelial-mesenchymal transdifferentiation (EMT) and its mechanism. Methods: Human renal tubular epithelial cells (HK-2) were cultured in vitro and subjected to high glucose concentration and time gradient experiments. First, for concentration gradient experiment, the sample was randomly divided into normal group, control group 1, control group 2, high glucose group 1, high glucose group 2. While for high glucose time gradient experiment, the sample was randomly divided into normal group, control group, high glucose 24 h group, high glucose 36 h group and high glucose 48 h group. Western blotting was used to detect the expression changes of Slit2, ROBO1, α-smooth muscle actin (α-SMA) and fibronectin in HK-2 cells, and then the optimal high glucose stimulation concentration and time were screened out. Slit2 over-expressed plasmid and negative control plasmid were transfected into HK-2 cells to verify the successful transfection, the cells were then randomly divided into normal group, control group, high glucose group, high glucose empty group and high glucose Slit2 group. The total protein was extracted after stimulation with optimal high glucose concentration and time, and Western blotting was then performed to detect the change in expression of fibronectin and α-SMA. Results: In the high glucose concentration gradient experiment, the expression of Slit2 declined significantly in high glucose group 1(0.647±0.048) and high glucose group 2(0.210±0.023) than in the normal group (1.000±0.050); the expression of ROBO1 declined significantly in high glucose group 1(0.703±0.041) and high glucose group 2(0.303±0.022) than in the normal group (1.000±0.057); while the expression of fibronectin increased significantly in high glucose group 1(1.953±0.042) and high glucose group 2(2.997±0.078) than in the normal group (0.990±0.059), and the expression of α-SMA increased significantly in high glucose group 1(1.767±0.012) and high glucose group 2(2.427±0.059) than in the normal group (1.033±0.067), all the differences were of statistical significance(P<0.05). Compared with the high glucose group 1, the expressions of Slit2 and ROBO1 decreased, and of fibronectin and α-SMA increased significantly in the high glucose group 2(P<0.05). In the high glucose time gradient experiment, compared with the normal group, the expressions of Slit2 in high glucose 36 h group and high glucose 48 h group decreased (0.943±0.032 vs. 0.557±0.020, 0.450±0.055, respectively), and the expression of ROBO1 decreased (1.000±0.058 vs. 0.600±0.023, 0.227±0.028, respectively). Compared with the normal group, the expression of fibronectin increased significantly in high glucose 24 h group, high glucose 36 h group and high glucose 48 h group (0.970±0.040 vs. 1.247±0.052, 1.733±0.084, 2.780±0.090, respectively), and the expression of α-SMA increased significantly in high glucose 24 h group, high glucose 36 h group and high glucose 48 h group (1.033±0.067 vs. 1.277±0.041, 1.767±0.120, 2.537±0.078, respectively), and the difference was statistically significant (P<0.05). Compared with high glucose 24 h group, the expression of Slit2 declined significantly in high glucose 36 h group and high glucose 48 h group(0.893±0.034 vs. 0.557±0.020, 0.450±0.055, respectively), and the expression of ROBO1 declined significantly (0.930±0.025 vs. 0.600±0.023, 0.227±0.028, respectively), the expressions of fibronectin and α-SMA increased significantly with statistical significance (P<0.05). Compared with high glucose 36 h group, the expression of Slit2 and ROBO1 declined significantly, and the expression of fibronectin and α-SMA increased significantly in high glucose 48 h group (P<0.05). In the high glucose environment, and achieving Slit2 overexpression and negative control plasmid transfection, the expression of fibronectin increased significantly in high glucose group, high glucose+empty group and high glucose+Slit2 group (2.760±0.012, 2.667±0.027, 1.460±0.034, respectively) than in normal group (1.000±0.058); the expression of α-SMA increased also in high glucose group, high glucose+empty group and high glucose+Slit2 group (2.487±0.048, 2.557±0.037, 1.270±0.017, respectively) than in normal group (1.000±0.050) with statistical significance (P<0.05). Compared with the high glucose+empty group, the expression of fibronectin and α-SMA declined significantly in the high glucose+Slit2 group(P<0.05). Conclusion: The decreased expression of Slit2 and ROBO1 is involved in the high glucose-induced renal tubular EMT. Overexpression of Slit2 may significantly inhibit the high glucose-induced EMT.

3.
Arch Orthop Trauma Surg ; 130(9): 1177-83, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20364263

RESUMO

INTRODUCTION: The treatment of displaced acetabular fractures with formal open reduction and internal fixation has gained general acceptance. However, extensile exposure can lead to complications. Two-dimensional fluoroscopy-based computerized navigation for placement of percutaneous screw across non-displaced acetabular fractures has attracted interest by making use of stored patient-specific imaging data to provide real-time guidance in multiple image planes during implant placement. The purpose of the present study was to document early treatment results and complications associated with this new technique and evaluate its clinical application to displaced acetabular fractures amenable to closed or limited open reduction. MATERIALS AND METHODS: Eighteen adult patients with 12 non-displaced and 8 displaced acetabular fractures were treated with percutaneous screw fixation under the guidance of a fluoroscopy-based navigation system. There were 14 men and four women with a mean age of 42.1 years (range 19-54 years). According to the AO and Orthopaedic Trauma Association Classification, there were nine 62-A3, five 62-B1, three 62-B2, and three 62-B3. The mean follow-up was 21 months (range 12-28 months). The mean time from injury to surgery was 4 days (range 2-7 days). RESULTS: A total of 30 acetabular screws were inserted, including 21 anterior column screws and 9 posterior column screws. The average operation time was 24.6 min (range 16-47 min) from the image acquisition to wound closure. The average fluoroscopic time was 28.4 s (range 11-58 s). Compared to the final position of the screw, the average deviated distance of wire tip was 2.5 mm (range 1.1-3.6 mm) and the average trajectory difference was 2.45 degrees (range 1.5 degrees -4.6 degrees ). Maximal gap displacement averaged 10 mm (range 2-22 mm) preoperatively and 3 mm (range 0-5 mm) postoperatively; while maximal step displacement averaged 4 mm (range 1-10 mm) preoperatively and 2 mm (range 0-4 mm) postoperatively. One patient sustained a transient femoral nerve palsy and resolved 2 months after the operation. No superficial or deep infection occurred. Using the rating system of D'Aubigne and Postel, 13 patients had excellent results, 4 patients had good results, and 1 patient had a fair result. CONCLUSION: Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based navigation could be applied not only to non-displaced fractures but also to displaced fractures amenable to closed or limited open reduction.


Assuntos
Acetábulo/lesões , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Cirurgia Assistida por Computador/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adulto , Parafusos Ósseos , Estudos de Coortes , Feminino , Fluoroscopia , Seguimentos , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura/fisiologia , Humanos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Radiografia Intervencionista , Medição de Risco , Resultado do Tratamento , Adulto Jovem
4.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-685131

RESUMO

Objective To compare the functional and radiographic outcomes of modified dual plating and less invasive stabilization system(LISS)in treatment of patients with complex tibial plateau fractures.Methods From November 2003 to November 2004,84 patients with complex tibial plateau fracture were treated with modified dual plating or LISS fixation.Their functional and radiographic outcomes were reviewed to compare the differences in bone union time,full weight-bearing time,knee joint's HSS(The Hospital for Special Surgery)scores,complications, tibia plateau angle(TPA)and posterior slope angle(PA).Results The 84 cases had complete follow-up records and a mean tollow-up of 16.2 months(range,12 to 23 months).Nine complications occurred in the modified dual plating group.The mean full weight-bearing time and radiographic bone union time were 16.8 and 15.1 weeks respectively for this group which had a mean HSS score of 87.4 points.Six complications were found in the LISS group.The mean full weight-bearing time and radiographic bone union time were 14.1 and 13.8 weeks respectively for this group which had a mean HSS score of 89.6 points.There were no significant differences between the two groups in changes of TPA and PA.Conclusion LISS can provide as good fixation as modified dual plating can for most complex tibial plateau fractures,but additional medial plate fixation may be necessary for some special cases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...