1.
Materials (Basel) ; 15(16)2022 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-36013630

RESUMO

Recently, the demand for spatial structures such as retractable dome roofs is increasing. The safety of dome roofs must be ensured even when they are open. Hence, studies analyzing the peak pressure coefficients of spherical dome roofs are actively being conducted. However, no peak pressure coefficients for the cladding design of elliptical retractable dome roofs have been proposed. Although several studies on elliptical open dome roofs that open from the edge to the center have been conducted, studies on those that open from the center to the edge are still insufficient. This study investigated the peak pressure coefficients of elliptical center-open dome roofs. For wind tunnel tests, a model was fabricated with an opening ratio of 30%. Under experimental conditions, five different wall height-to-span ratios (from 0.1 to 0.5) were used, with the roof rise-to-span ratio set at 0.1. Accordingly, the experimental values of the peak pressure coefficients of elliptical center-open dome roofs were compared with those of the closed dome roofs proposed in the Korean and Japanese wind load codes. Subsequently, their efficiency was verified. The findings were also compared with previous research outcomes. Based on the results, peak net pressure coefficients are proposed for cladding designs suitable for elliptical center-open dome roofs.

2.
Materials (Basel) ; 14(18)2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34576493

RESUMO

Cladding for dome roofs is often made of membrane materials that are light and easy to install. Due to these characteristics, wind damage to dome roof cladding is very common. In particular, open or retractable dome roofs are prone to wind damage because of inadequacies in wind load calculations. In this study, the wind pressure characteristics of a dome with a central opening were investigated. Wind tunnel tests were performed, and the pressure distribution was investigated by analyzing external and internal pressure coefficients. Based on the experimental results, the peak net pressure coefficients for the cladding design of a dome roof with a central opening were proposed. For the external peak pressure coefficients, the values of leeward regions were similar despite height-span ratios and turbulence intensity values. For the internal peak pressure coefficients, negative pressure was dominant, and the coefficients were not significantly affected by changes in height-span ratio. This tendency locally increased the negative peak net pressure, in which the load acts in the upward direction, and relatively significantly increased the positive peak net pressure, in which the load acts in the downward direction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...