AIMS: The safety and performance of the Absorb Bioresorbable Vascular Scaffold (Absorb BVS) system (Abbott Vascular, Santa Clara, CA, USA) has been previously established in 131 patients from cohort A and cohort B of the first-in-man ABSORB trial. Following this trial, ABSORB EXTEND was initiated as a global continued access study (outside of the USA) to expand experience with the Absorb BVS system to different geographies with broader inclusion criteria to include the treatment of longer lesions and multiple vessels. We report in this manuscript the twelve-month clinical outcomes of the first 512 patients in this population. METHODS AND RESULTS: ABSORB EXTEND is a prospective, single-arm, open-label clinical study which will enrol up to 800 patients at up to 100 sites. Included are patients with lesions ≤28 mm in length and reference vessel diameter of 2.0-3.8 mm (as assessed by on-line QCA or IVUS). Treatment of a maximum of two de novo native coronary artery lesions is permitted when each lesion is located in a different epicardial vessel. An independent clinical events committee adjudicates all endpoint-related events. At one year, for the first 512 patients enrolled in the study, the composite endpoints of ischaemia-driven MACE and ischaemia-driven target vessel failure were 4.3% and 4.9%, respectively. The cumulative rate of ARC defined definite and probable scaffold thrombosis for this population was 0.8% at one year. CONCLUSIONS: This interim analysis of the ABSORB EXTEND study shows low rates of MACE and scaffold thrombosis. The study is registered on clinicaltrials.gov (unique identifier NCT01023789).
Assuntos
Implantes Absorvíveis , Antineoplásicos/uso terapêutico , Estenose Coronária/terapia , Stents Farmacológicos , Everolimo/uso terapêutico , Intervenção Coronária Percutânea , Alicerces Teciduais , Idoso , Estudos de Coortes , Trombose Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica , Estudos Prospectivos , Tomografia de Coerência Óptica , Resultado do TratamentoRESUMO
Aims: The safety and performance of the Absorb Bioresorbable Vascular Scaffold (Absorb BVS) system(Abbott Vascular, Santa Clara, CA, USA) has been previously established in 131 patients from cohort A andcohort B of the first-in-man ABSORB trial. Following this trial, ABSORB EXTEND was initiated as a globalcontinued access study (outside of the USA) to expand experience with the Absorb BVS system to differentgeographies with broader inclusion criteria to include the treatment of longer lesions and multiple vessels.We report in this manuscript the twelve-month clinical outcomes of the first 512 patients in this population.Methods and results: ABSORB EXTEND is a prospective, single-arm, open-label clinical study whichwill enrol up to 800 patients at up to 100 sites. Included are patients with lesions ≤28 mm in length and referencevessel diameter of 2.0-3.8 mm (as assessed by on-line QCA or IVUS). Treatment of a maximum oftwo de novo native coronary artery lesions is permitted when each lesion is located in a different epicardialvessel. An independent clinical events committee adjudicates all endpoint-related events. At one year, for thefirst 512 patients enrolled in the study, the composite endpoints of ischaemia-driven MACE and ischaemiadriventarget vessel failure were 4.3% and 4.9%, respectively. The cumulative rate of ARC defined definiteand probable scaffold thrombosis for this population was 0.8% at one year.Conclusions: This interim analysis of the ABSORB EXTEND study shows low rates of MACE and scaffoldthrombosis. The study is registered on clinicaltrials.gov (unique identifier NCT01023789).
Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Stents FarmacológicosRESUMO
Aims: The safety and performance of the Absorb Bioresorbable Vascular Scaffold (Absorb BVS) system(Abbott Vascular, Santa Clara, CA, USA) has been previously established in 131 patients from cohort A andcohort B of the first-in-man ABSORB trial. Following this trial, ABSORB EXTEND was initiated as a globalcontinued access study (outside of the USA) to expand experience with the Absorb BVS system to differentgeographies with broader inclusion criteria to include the treatment of longer lesions and multiple vessels. Wereport in this manuscript the twelve-month clinical outcomes of the first 512 patients in this population.Methods and results: ABSORB EXTEND is a prospective, single-arm, open-label clinical study whichwill enrol up to 800 patients at up to 100 sites. Included are patients with lesions ≤28 mm in length and referencevessel diameter of 2.0-3.8 mm (as assessed by on-line QCA or IVUS). Treatment of a maximum of twode novo native coronary artery lesions is permitted when each lesion is located in a different epicardial vessel.An independent clinical events committee adjudicates all endpoint-related events. At one year, for the first512 patients enrolled in the study, the composite endpoints of ischaemia-driven MACE and ischaemia-driventarget vessel failure were 4.3% and 4.9%, respectively. The cumulative rate of ARC defined definite andprobable scaffold thrombosis for this population was 0.8% at one year.Conclusions: This interim analysis of the ABSORB EXTEND study shows low rates of MACE and scaffoldthrombosis. The study is registered on clinicaltrials.gov (unique identifier NCT01023789).