Phys Med Biol ; 58(16): 5495-510, 2013 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-23880523

RESUMO

AX-PET is a novel PET detector based on axially oriented crystals and orthogonal wavelength shifter (WLS) strips, both individually read out by silicon photo-multipliers. Its design decouples sensitivity and spatial resolution, by reducing the parallax error due to the layered arrangement of the crystals. Additionally the granularity of AX-PET enhances the capability to track photons within the detector yielding a large fraction of inter-crystal scatter events. These events, if properly processed, can be included in the reconstruction stage further increasing the sensitivity. Its unique features require dedicated Monte-Carlo simulations, enabling the development of the device, interpreting data and allowing the development of reconstruction codes. At the same time the non-conventional design of AX-PET poses several challenges to the simulation and modeling tasks, mostly related to the light transport and distribution within the crystals and WLS strips, as well as the electronics readout. In this work we present a hybrid simulation tool based on an analytical model and a Monte-Carlo based description of the AX-PET demonstrator. It was extensively validated against experimental data, providing excellent agreement.


Assuntos
Método de Monte Carlo , Tomografia por Emissão de Pósitrons/instrumentação
2.
Nucl Instrum Methods Phys Res A ; 702: 88-90, 2013 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-23440608

RESUMO

Silicon based devices can extend PET-MR and SPECT-MR imaging to applications, where their advantages in performance outweigh benefits of high statistical counts.Silicon is in many ways an excellent detector material with numerous advantages, among others: excellent energy and spatial resolution, mature processing technology, large signal to noise ratio, relatively low price, availability, versatility and malleability. The signal in silicon is also immune to effects of magnetic field at the level normally used in MR devices. Tests in fields up to 7 T were performed in a study to determine effects of magnetic field on positron range in a silicon PET device. The curvature of positron tracks in direction perpendicular to the field's orientation shortens the distance between emission and annihilation point of the positron. The effect can be fully appreciated for a rotation of the sample for a fixed field direction, compressing range in all dimensions. A popular Ga-68 source was used showing a factor of 2 improvement in image noise compared to zero field operation. There was also a little increase in noise as the reconstructed resolution varied between 2.5 and 1.5 mm.A speculative applications can be recognized in both emission modalities, SPECT and PET.Compton camera is a subspecies of SPECT, where a silicon based scatter as a MR compatible part could inserted into the MR bore and the secondary detector could operate in less constrained environment away from the magnet. Introducing a Compton camera also relaxes requirements of the radiotracers used, extending the range of conceivable photon energies beyond 140.5 keV of the Tc-99m.In PET, one could exploit the compressed sub-millimeter range of positrons in the magnetic field. To exploit the advantage, detectors with spatial resolution commensurate to the effect must be used with silicon being an excellent candidate. Measurements performed outside of the MR achieving spatial resolution below 1 mm are reported.

3.
Nucl Instrum Methods Phys Res A ; 699(21): 216-220, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23230345

RESUMO

Positron emission tomography (PET) is a widely used technique in medical imaging and in studying small animal models of human disease. In the conventional approach, the 511 keV annihilation photons emitted from a patient or small animal are detected by a ring of scintillators such as LYSO read out by arrays of photodetectors. Although this has been a successful in achieving ~5mm FWHM spatial resolution in human studies and ~1mm resolution in dedicated small animal instruments, there is interest in significantly improving these figures. Silicon, although its stopping power is modest for 511 keV photons, offers a number of potential advantages over more conventional approaches. Foremost is its high spatial resolution in 3D: our past studies show that there is little diffculty in localizing 511 keV photon interactions to ~0.3mm. Since spatial resolution and reconstructed image noise trade off in a highly non-linear manner that depends on the PET instrument response, if high spatial resolution is the goal, silicon may outperform standard PET detectors even though it has lower sensitivity to 511 keV photons. To evaluate silicon in a variety of PET "magnifying glass" configurations, an instrument has been constructed that consists of an outer partial-ring of PET scintillation detectors into which various arrangements of silicon detectors can be inserted to emulate dual-ring or imaging probe geometries. Recent results have demonstrated 0.7 mm FWHM resolution using pad detectors having 16×32 arrays of 1.4mm square pads and setups have shown promising results in both small animal and PET imaging probe configurations. Although many challenges remain, silicon has potential to become the PET detector of choice when spatial resolution is the primary consideration.

4.
Radiat Prot Dosimetry ; 139(1-3): 199-203, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20215445

RESUMO

Simulation indicates that PET image could be improved by upgrading a conventional ring with a probe placed close to the imaged object. In this paper, timing issues related to a PET probe using high-resistivity silicon as a detector material are addressed. The final probe will consist of several (four to eight) 1-mm thick layers of silicon detectors, segmented into 1 x 1 mm(2) pads, each pad equivalent to an independent p + nn+ diode. A proper matching of events in silicon with events of the external ring can be achieved with a good timing resolution. To estimate the timing performance, measurements were performed on a simplified model probe, consisting of a single 1-mm thick detector with 256 square pads (1.4 mm side), coupled with two VATAGP7s, application-specific integrated circuits. The detector material and electronics are the same that will be used for the final probe. The model was exposed to 511 keV annihilation photons from an (22)Na source, and a scintillator (LYSO)-PMT assembly was used as a timing reference. Results were compared with the simulation, consisting of four parts: (i) GEANT4 implemented realistic tracking of electrons excited by annihilation photon interactions in silicon, (ii) calculation of propagation of secondary ionisation (electron-hole pairs) in the sensor, (iii) estimation of the shape of the current pulse induced on surface electrodes and (iv) simulation of the first electronics stage. A very good agreement between the simulation and the measurements were found. Both indicate reliable performance of the final probe at timing windows down to 20 ns.


Assuntos
Aumento da Imagem/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Silício , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Phys Rev Lett ; 94(12): 121301, 2005 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-15903903

RESUMO

Hypothetical axionlike particles with a two-photon interaction would be produced in the sun by the Primakoff process. In a laboratory magnetic field ("axion helioscope"), they would be transformed into x-rays with energies of a few keV. Using a decommissioned Large Hadron Collider test magnet, the CERN Axion Solar Telescope ran for about 6 months during 2003. The first results from the analysis of these data are presented here. No signal above background was observed, implying an upper limit to the axion-photon coupling g(agamma)<1.16x10(-10) GeV-1 at 95% C.L. for m(a) less, similar 0.02 eV. This limit, assumption-free, is comparable to the limit from stellar energy-loss arguments and considerably more restrictive than any previous experiment over a broad range of axion masses.

6.
Phys Med Biol ; 49(12): 2547-62, 2004 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-15272673

RESUMO

A novel concept for a positron emission tomography (PET) camera module is proposed, which provides full 3D reconstruction with high resolution over the total detector volume, free of parallax errors. The key components are a matrix of long scintillator crystals and hybrid photon detectors (HPDs) with matched segmentation and integrated readout electronics. The HPDs read out the two ends of the scintillator package. Both excellent spatial (x, y, z) and energy resolution are obtained. The concept allows enhancing the detection efficiency by reconstructing a significant fraction of events which underwent Compton scattering in the crystals. The proof of concept will first be demonstrated with yttrium orthoaluminate perovskite (YAP):Ce crystals, but the final design will rely on other scintillators more adequate for PET applications (e.g. LSO:Ce or LaBr3:Ce). A promising application of the proposed camera module, which is currently under development, is a high resolution 3D brain PET camera with an axial field-of-view of approximately 15 cm dedicated to brain research. The design philosophy and performance predictions based on analytical calculations and Monte Carlo simulations are presented. Image correction and reconstruction tools required to operate this transmissionless device in a research environment are also discussed. Better or similar performance parameters were obtained compared to other known designs at lower fabrication cost. The axial geometrical concept also seems to be promising for applications such as positron emission mammography.


Assuntos
Encéfalo/diagnóstico por imagem , Análise de Falha de Equipamento , Aumento da Imagem/instrumentação , Imageamento Tridimensional/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Encéfalo/metabolismo , Desenho de Equipamento , Estudos de Viabilidade , Câmaras gama , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Pesquisa/instrumentação , Sensibilidade e Especificidade
8.
IARC Sci Publ ; (97): 105-11, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2164499

RESUMO

A historical mortality study was conducted among 520 silicotic subjects diagnosed at the Department of Occupational Health of the San Martino Hospital, Genoa, Italy, between 1961 and 1980. Vital status was ascertained as of 1 January 1982. Age-, sex- and calendar-year-adjusted standardized mortality ratios (SMRs) for specific causes were computed using Italian as well as Genoa County male population death rates. The study shows statistically significant increased mortality from all deaths (SMR = 2.92), all cancers (SMR = 2.38), respiratory tract cancers (SMR = 6.85), respiratory tract diseases (SMR = 13.63), and from 'other diseases' (SMR = 6.81). The excess mortality from respiratory tract diseases and from 'other diseases' are mainly attributable to silicosis and silicotuberculosis, respectively. These findings confirm the existence of a causal association between silicosis and increased mortality from both malignant and non-malignant respiratory tract diseases. The high mortality from respiratory tract cancers was still present even after adjustment for smoking.


Assuntos
Neoplasias Pulmonares/mortalidade , Dióxido de Silício , Silicose/mortalidade , Adulto , Idoso , Causas de Morte , Exposição Ambiental , Métodos Epidemiológicos , Humanos , Itália , Pneumopatias/epidemiologia , Pneumopatias/mortalidade , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Silicose/complicações , Silicose/epidemiologia , Fumar/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...