Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
1.
JACC Cardiovasc Interv ; 17(14): 1667-1675, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39048253

RESUMO

BACKGROUND: Outcomes from transcatheter aortic valve replacement (TAVR) in low-surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. OBJECTIVES: This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. METHODS: The Evolut Low Risk Bicuspid Study is a prospective, multicenter, single-arm study conducted in 25 U.S. CENTERS: Patients with severe aortic stenosis at low surgical risk with bicuspid aortic valve anatomy (all subtypes) underwent TAVR with a self-expanding, supra-annular Evolut R or PRO (Medtronic) bioprosthesis. An independent clinical events committee adjudicated all deaths and endpoint-related adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 150 patients from December 2018 to October 2019. The mean age was 70.3 ± 5.5 years, 48% (72/150) of the patients were women, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 1.3% (Q1-Q3: 0.9%-1.7%). Sievers type 1 was the dominant bicuspid morphology (90.7%, 136/150). The Kaplan-Meier rates of all-cause mortality or disabling stroke were 1.3% (95% CI: 0.3%-5.3%) at 1 year, 3.4% (95% CI: 1.4%-8.1%) at 2 years, and 4.1% (95% CI: 1.6%-10.7%) at 3 years. The incidence of new permanent pacemaker implantation was 19.4% (95% CI: 12.4%-29.6%) at 3 years. There were no instances of moderate or severe paravalvular aortic regurgitation at 2 and 3 years after TAVR. CONCLUSIONS: The 3-year results from the Evolut Low Risk Bicuspid Study demonstrate low rates of all-cause mortality or disabling stroke and favorable hemodynamic performance.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Fatores de Risco , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Medição de Risco , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Estados Unidos/epidemiologia , Índice de Gravidade de Doença , Complicações Pós-Operatórias/mortalidade , Recuperação de Função Fisiológica , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/mortalidade
2.
Artigo em Inglês | MEDLINE | ID: mdl-38871537

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.

3.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747561

RESUMO

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38599918

RESUMO

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

5.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658126

RESUMO

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Artéria Femoral , Nível de Saúde , Próteses Valvulares Cardíacas , Qualidade de Vida , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Idoso , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Periférico/efeitos adversos , Punções , Desenho de Prótese
6.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38573257

RESUMO

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Incidência , Retratamento
7.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38552656

RESUMO

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Cardiovasc Revasc Med ; 58: 60-67, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37550123

RESUMO

BACKGROUND: Patients with high bleeding risk (HBR) are often treated with abbreviated dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) to reduce bleeding risk, however this strategy is associated with an increase in ischemic events, especially if the acute PCI result is suboptimal. We compared clinical outcomes among patients with HBR treated with 1-month DAPT who underwent intravascular ultrasound (IVUS)- or optical coherence tomography (OCT)-guided PCI versus those who underwent angiography-guided PCI without intravascular imaging. METHODS: The Onyx ONE Clear study includes patients with HBR from the Onyx ONE US/Japan and Onyx ONE randomized studies who were treated with the Resolute Onyx zotarolimus-eluting stent. The primary endpoint was the composite of cardiac death (CD) or myocardial infarction (MI) between 1 month and 2 years after PCI. Propensity-score adjustments and matching were performed for differences in baseline and procedural characteristics between groups. RESULTS: Among the 1507 patients in Onyx ONE Clear, 271 (18.0 %) had IVUS or OCT used during PCI (Imaging-guided group) and 1236 (82.0 %) underwent Angiography-guided PCI (Angio-guided group). Imaging-guided patients were less likely to present with atrial fibrillation, acute coronary syndrome, and left ventricle ejection fraction ≤35 %. Conversely, Imaging-guided patients were more likely to have complex (ACC/AHA type B2/C), longer, and heavily calcified lesions. Between 1 month and 2 years, the composite rate of CD or MI was similar between Imaging-guided and Angio-guided patients (9.9 % vs. 12.4 %, P = 0.33). There was also no difference between groups after adjustment; (P = 0.56). However, CD was significantly lower among Imaging-guided patients (2.7 % vs. 6.1 %, P = 0.048). There were no between-group differences in MI or stent thrombosis. Propensity score matching results were similar. CONCLUSION: Despite higher lesion complexity, using intravascular imaging guidance for PCI between 1-month and 2-years follow-up had comparable outcomes with angiographic guidance alone in patients with HBR treated with 1-month DAPT. (ClinicalTrials.gov: Identifier: NCT03647475 and NCT03344653). NON-STANDARD ABBREVIATIONS AND ACRONYMS: BARC: Bleeding Academic Research Consortium; DAPT: dual antiplatelet therapy; DES: drug-eluting stent; HBR: high bleeding risk; IVUS: intravascular ultrasound; OCT: optical coherence tomography; SAPT: single antiplatelet therapy.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Stents Farmacológicos/efeitos adversos , Infarto do Miocárdio/terapia , Infarto do Miocárdio/tratamento farmacológico , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/efeitos adversos , Resultado do Tratamento , Estudos Prospectivos
9.
Am J Cardiol ; 214: 1-7, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38110018

RESUMO

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Seguimentos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Instrumentos Cirúrgicos , Desenho de Prótese , Fatores de Risco
10.
Am J Cardiol ; 213: 99-105, 2024 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-38110022

RESUMO

The association, if any, between the effective regurgitant orifice area (EROA) to left ventricular end-diastolic volume (LVEDV) ratio and 1-year mortality is controversial in patients who undergo mitral transcatheter edge-to-edge repair (m-TEER) with the MitraClip system (Abbott Vascular, Santa Clara, CA). This study's objective was to determine the association between EROA/LVEDV and 1-year mortality in patients who undergo m-TEER with MitraClip. In patients with severe secondary (functional) mitral regurgitation (MR), we analyzed registry data from 11 centers using generalized linear models with the generalized estimating equations approach. We studied 525 patients with secondary MR who underwent m-TEER. Most patients were male (63%) and were New York Heart Association class III (61%) or IV (21%). Mitral regurgitation was caused by ischemic cardiomyopathy in 51% of patients. EROA/LVEDV values varied widely, with median = 0.19 mm2/ml, interquartile range [0.12,0.28] mm2/ml, and 187 patients (36%) had values <0.15 mm2/ml. Postprocedural mitral regurgitation severity was substantially alleviated, being 1+ or less in 74%, 2+ in 20%, 3+ in 4%, and 4+ in 2%; 1-year mortality was 22%. After adjustment for confounders, the logarithmic transformation (Ln) of EROA/LVEDV was associated with 1-year mortality (odds ratio 0.600, 95% confidence interval 0.386 to 0.933, p = 0.023). A higher Society of Thoracic Surgeons risk score was also associated with increased mortality. In conclusion, lower values of Ln(EROA/LVEDV) were associated with increased 1-year mortality in this multicenter registry. The slope of the association is steep at low values but gradually flattens as Ln(EROA/LVEDV) increases.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Masculino , Feminino , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Resultado do Tratamento , Sistema de Registros , América do Norte
11.
Am J Cardiol ; 208: 37-43, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37812864

RESUMO

Optimal timing for aortic valve replacement in symptomatic patients with less than severe aortic stenosis (AS) is not well defined. There is limited information on the benefit of valve replacement in these patients. Symptomatic patients with less than severe AS, defined as a mean aortic gradient ≥20 and <40 mm Hg, peak aortic velocity >3 and <4 m/s, and aortic valve area >1.0 and <1.5 cm2, enrolled in the Society for Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy Registry and who underwent attempted supra-annular, self-expanding transcatheter aortic valve replacement (TAVR) were reviewed. Site-reported valve hemodynamics, clinical events, and quality of life metrics were analyzed at 30 days and 1 year after the procedure. A total of 1,067 patients with attempted TAVR (mean age 78.4 ± 8.4 years; Society for Thoracic Surgery score 4.7 ± 3.4%) were found to have symptoms but less than severe AS. From baseline to postprocedure, mean gradient decreased (29.9 ± 4.9 vs 8.4 ± 4.8 mm Hg, p <0.001), and aortic valve area increased (1.2 ± 0.1 vs 2.2 ± 0.7 cm2, p <0.001). Clinical events included 30-day and 1-year all-cause mortality (1.5% and 9.6%), stroke (2.2% and 3.3%), and new pacemaker implantation (18.1% and 20.9%). There were statistically significant improvements in the New York Heart Association functional class and Kansas City Cardiomyopathy Questionnaire at 30 days and 1 year. In conclusion, patients with symptomatic but less than severe AS who underwent supra-annular, self-expanding TAVR experienced improved valve hemodynamics and quality of life measures 1 year after the procedure. Randomized studies of TAVR versus a control arm in symptomatic patients with less than severe AS are ongoing.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia , Fatores de Risco
12.
JACC Heart Fail ; 11(10): 1351-1362, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37480877

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF). OBJECTIVES: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden. METHODS: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days). The investigators determined the association of baseline AF burden with long-term clinical events and examined the effect of atrial shunt therapy on AF burden over time. RESULTS: Among 367 patients with cardiac monitoring data at baseline and follow-up, 194 (53%) had a history of AF or atrial flutter (AFL), and median baseline AF burden was 0.012% (IQR: 0%-1.3%). After multivariable adjustment, baseline AF burden ≥0.012% was significantly associated with heart failure (HF) events (HR: 2.00; 95% CI: 1.17-3.44; P = 0.01) both with and without a history of AF or AFL (P for interaction = 0.68). Adjustment for left atrial reservoir strain attenuated the baseline AF burden-HF event association (HR: 1.71; 95% CI: 0.93-3.14; P = 0.08). Of the 367 patients, 141 (38%) had patch-detected AF during follow-up without a history of AF or AFL. Atrial shunt therapy did not change AF incidence or burden during follow-up. CONCLUSIONS: In HFpEF and HFmrEF, nearly 40% of patients have subclinical AF by 1 year. Baseline AF burden, even at low levels, is associated with HF events. Atrial shunt therapy does not affect AF incidence or burden. (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure [REDUCE LAP-HF II]; NCT03088033).


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/epidemiologia , Volume Sistólico , Átrios do Coração , Implantação de Prótese , Prognóstico
13.
JACC Cardiovasc Interv ; 16(13): 1626-1635, 2023 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-37438029

RESUMO

BACKGROUND: The latest-generation Evolut FX TAVR system (Medtronic) offers several potential design improvements over its predecessors, but early reported experience has been limited. OBJECTIVES: This study sought to report our multicenter, limited market release, first-in-human experience of transcatheter aortic valve replacement (TAVR) with the Evolut FX system and compare it with a single-center PRO+ (Medtronic) experience. METHODS: From June 27 to September 16, 2022, 226 consecutive patients from 9 US centers underwent transfemoral TAVR with the Evolut FX system for native aortic stenosis (89.4%) or prosthetic valve degeneration (10.6%). Commissural alignment was defined as 0° to 30° between native and FX commissures. Patient, anatomical, and procedural characteristics were retrospectively reviewed, and 30-day clinical and echocardiographic outcomes per Valve Academic Research Consortium-3 definitions were reported. RESULTS: Of 226 patients, 34.1% were low risk, 4% had a bicuspid valve, and 11.5% had a horizontal root (≥60°). Direct Inline sheath (Medtronic) was used in 67.6% and Lunderquist stiff wire (Cook Medical) in 35.4% of cases. Optimal hat marker orientation during deployment was achieved in 98.4%, with commissural alignment in 96.5%. At 30 days, 14.3% mild, 0.9% moderate, and no severe paravalvular leak were observed. Compared with the Evolut PRO+ experience from 1 center, FX had a more symmetrical implantation with shallower depth at the left coronary cusp (P < 0.001), fewer device recaptures (26.1% vs 39.5%; P = 0.004), and improved commissural alignment (96.5% vs 80.2%; P < 0.001). CONCLUSIONS: The Evolut FX system demonstrated favorable 30-day outcomes with a significant improvement over PRO+ in achieving commissural alignment, fewer device recaptures, and more symmetrical implantation. These features may benefit younger patients undergoing TAVR with the supra-annular, self-expanding valve, where lifetime management would be important.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Catéteres
14.
Struct Heart ; 7(3): 100164, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37273856

RESUMO

Background: Cardiac computed tomography angiography was used to identify anatomical characteristics of the aortic root in patients with severe aortic regurgitation (AR) as compared to those with aortic stenosis (AS) to judge feasibility of transcatheter aortic valve replacement (TAVR) with the JenaValve Trilogy system. Methods: Cardiac computed tomography angiography was performed prior to planned TAVR for 107 patients with severe AR and 92 patients with severe AS. Measurements related to aortic root and coronary artery anatomy were obtained and compared between groups. Perimeter >90 mm and aortic annulus angle â€‹>70 degrees were defined as the theoretical exclusion criteria for TAVR. A combination of sinus of Valsalva diameter <30 mm and coronary height <12 mm was defined as high risk for coronary occlusion. Results: The mean age of patients in the AR group was 74.9 ± 11.2 years, 46% were women, and the mean Society of Thoracic Surgeons risk score for mortality was 3.6 ± 2.1. Comparatively, the mean age of patients in the AS group was 82.3 ± 5.53 years, 65% were women, and the mean Society of Thoracic Surgeonsrisk score was 5.5 ± 3.3. Annulus area, perimeter, diameter, and angle were larger in patients with severe AR. Sinus of Valsalva diameters and heights were larger in patients with severe AR. More AR patients were excluded based on perimeter (14 vs. 2%) and annulus angle (6 vs. 1%). More AS patients exhibited high-risk anatomy for left main coronary occlusion (21 vs. 7%) and right coronary occlusion (14 vs. 3%). The maximum dimension of the ascending aorta was larger in patients with severe AR (39 vs. 35 mm). The percentage of referred AR patients with significant aortopathy requiring surgical intervention was very low (only 1 AR patient with ascending aorta diameter >5.5 cm). Conclusions: A significantly larger proportion of patients with severe AR are excluded from TAVR as compared to AS due to large aortic annulus size and steep annulus angulation. By far the most prevalent excluding factor is aortic annulus size, with fewer patients excluded due to angulation. AR patients have lower-risk anatomy for coronary occlusion. Larger transcatheter valve sizes and further delivery system modifications are required to treat a larger proportion of AR patients.

15.
JACC Cardiovasc Interv ; 16(8): 942-953, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-37100557

RESUMO

BACKGROUND: Aortic stenosis treatment should consider risks and benefits for lifetime management. Although the feasibility of redo transcatheter aortic valve replacement (TAVR) remains unclear, concerns are emerging regarding reoperation after TAVR. OBJECTIVES: The authors sought to define comparative risk of surgical aortic valve replacement (SAVR) after prior TAVR or SAVR. METHODS: Data on patients undergoing bioprosthetic SAVR after TAVR and/or SAVR were extracted from the Society of Thoracic Surgeons Database (2011-2021). Overall and isolated SAVR cohorts were analyzed. The primary outcome was operative mortality. Risk adjustment using hierarchical logistic regression as well as propensity score matching for isolated SAVR cases were performed. RESULTS: Of 31,106 SAVR patients, 1,126 had prior TAVR (TAVR-SAVR), 674 had prior SAVR and TAVR (SAVR-TAVR-SAVR), and 29,306 had prior SAVR (SAVR-SAVR). Yearly rates of TAVR-SAVR and SAVR-TAVR-SAVR increased over time, whereas SAVR-SAVR was stable. The TAVR-SAVR patients were older, with higher acuity, and with greater comorbidities than other cohorts. The unadjusted operative mortality was highest in the TAVR-SAVR group (17% vs 12% vs 9%, respectively; P < 0.001). Compared with SAVR-SAVR, risk-adjusted operative mortality was significantly higher for TAVR-SAVR (OR: 1.53; P = 0.004), but not SAVR-TAVR-SAVR (OR: 1.02; P = 0.927). After propensity score matching, operative mortality of isolated SAVR was 1.74 times higher for TAVR-SAVR than SAVR-SAVR patients (P = 0.020). CONCLUSIONS: The number of post-TAVR reoperations is increasing and represent a high-risk population. Yet even in isolated SAVR cases, SAVR after TAVR is independently associated with increased risk of mortality. Patients with life expectancy beyond a TAVR valve and unsuitable anatomy for redo-TAVR should consider a SAVR-first approach.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Medição de Risco , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Fatores de Risco
16.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-36882136

RESUMO

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Masculino , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia
17.
JACC Cardiovasc Interv ; 16(5): 558-570, 2023 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-36922042

RESUMO

BACKGROUND: Procedural success and clinical outcomes after transcatheter aortic valve replacement (TAVR) have improved, but residual aortic regurgitation (AR) and new permanent pacemaker implantation (PPI) rates remain variable because of a lack of uniform periprocedural management and implantation. OBJECTIVES: The Optimize PRO study evaluates valve performance and procedural outcomes using an "optimized" TAVR care pathway and the cusp overlap technique (COT) in patients receiving the Evolut PRO/PRO+ (Medtronic) self-expanding valves. METHODS: Optimize PRO, a nonrandomized, prospective, postmarket study conducted in the United States, Canada, Europe, Middle East, and Australia, is enrolling patients with severe symptomatic aortic stenosis and no pre-existing pacemaker. Sites follow a standardized TAVR care pathway, including early discharge and a conduction disturbance management algorithm, and transfemoral deployment using the COT. RESULTS: A total of 400 attempted implants from the United States and Canada comprised the main cohort of this second interim analysis. The mean age was 78.7 ± 6.6 years, and the mean Society of Thoracic Surgeons predictive risk of mortality was 3.0 ± 2.4. The median length of stay was 1 day. There were no instances of moderate or severe AR at discharge. At 30 days, all-cause mortality or stroke was 3.8%, all-cause mortality was 0.8%, disabling stroke was 0.7%, hospital readmission was 10.1%, and cardiovascular rehospitalization was 6.1%. The new PPI rate was 9.8%, 5.8% with 4-step COT compliance. In the multivariable model, right bundle branch block and the depth of the implant increased the risk of PPI, whereas using the 4-step COT lowered 30-day PPI. CONCLUSIONS: The use of the TAVR care pathway and COT resulted in favorable clinical outcomes with no moderate or severe AR and low PPI rates at 30 days while facilitating early discharge and reproducible outcomes across various sites and operators. (Optimize PRO; NCT04091048).


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Estados Unidos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Procedimentos Clínicos , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Insuficiência da Valva Aórtica/etiologia , Próteses Valvulares Cardíacas/efeitos adversos
18.
Catheter Cardiovasc Interv ; 101(4): 756-763, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36748804

RESUMO

BACKGROUND: TandemHeart has been demonstrated to improve hemodynamic and metabolic complications in cardiogenic shock (CS). Contemporary outcomes have not been reported. OBJECTIVES: To evaluate the outcomes of the TandemHeart (LivaNova) in contemporary real-world use. METHODS: We analyzed baseline characteristics, hemodynamic changes, and outcomes of all patients treated with TandemHeart who were enrolled in the THEME registry, a multicenter, prospective, observational study. RESULTS: Between May 2015 and June 2019, 50 patients underwent implantation of the TandemHeart device. 22% of patients had TandemHeart implanted within 12 h, 32% within 24 h, and 52% within 48 h of CS diagnosis. Cardiac index (CI) was significantly improved 24 h after implantation (median change 1.0, interquartile range (IQR) (0.5-1.4 L/min/m2 ). In survivors, there was a significant improvement in CI (1.0, IQR (0.5-2.25 L/min/m2 ) and lactate clearance -2.3 (-5.0 to -0.7 mmol/L). The 30-day and 180-day survival were 74% (95% confidence interval: 60%-85%) and 66% (95% confidence interval: 51%-79%), respectively. Survival was similarly high in those in whom TandemHeart has been used as a bridge to surgery (85% 180-day survival). CONCLUSION: In a contemporary cohort of patients presenting in CS, the use of TandemHeart is associated with a 74% 30-day survival and a 66% 180-day survival.


Assuntos
Coração Auxiliar , Choque Cardiogênico , Humanos , Choque Cardiogênico/terapia , Estudos Prospectivos , Coração Auxiliar/efeitos adversos , Resultado do Tratamento , Sistema de Registros
19.
JACC Cardiovasc Interv ; 16(2): 168-176, 2023 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-36697152

RESUMO

BACKGROUND: The 30-day rate of stroke after transcatheter aortic valve replacement (TAVR) has been suggested as a hospital quality metric. Thirty-day stroke rates for nonsurgical, high, and moderate-risk TAVR trials were 3.4% to 6.1%, whereas those in the national Transcatheter Valve Therapy (TVT) Registry for the same patient population were much lower. Hospital comprehensive stroke center (CSC) is the highest designation for integrated acute stroke recognition, management, and care. OBJECTIVES: Using Michigan TVT data, we assessed whether in-hospital post-TAVR stroke rates varied between CSC and non-CSC institutions. METHODS: TVT data submitted from the 22 Michigan Transcatheter Aortic Valve Replacement Collaborative participating institutions between January 1, 2016, and June 30, 2019, were included (N = 6,231). Bayesian hierarchical regression models accounting for patient clinical characteristics and hospital clustering were fitted to assess the association between hospital CSC accreditation and in-hospital post-TAVR stroke. Adjusted ORs and 95% credible intervals were estimated. The University of Michigan Institutional Review Board has waived the need for the approval of studies based on the data collected by the Blue Cross Blue Shield of Michigan Cardiovascular Consortium registry. RESULTS: There were 3,882 (62.3%) patients at 9 CSC sites and 2,349 (37.7%) patients at 13 non-CSC sites. CSC sites had significantly higher rates of in-hospital post-TAVR stroke (CSC: 2.65% vs non-CSC: 1.15%; P < 0.001). After adjustment, patients who underwent TAVR at a CSC hospital had a significantly higher risk of in-hospital stroke (adjusted OR: 2.21; 95% CI: 1.03-4.62). However, CSC designation was not significantly associated with other important post-TAVR clinical outcomes including 30-day mortality. CONCLUSIONS: Reported Michigan Transcatheter Aortic Valve Replacement Collaborative TVT stroke rates were significantly higher at sites with Joint Hospital Commission stroke designation status; however, other reported important clinical outcomes did not differ significantly based on this designation. CSC designation is a possible factor in stroke rate detection differences between TAVR institutions and might be a factor in the observed differences in stroke rates between TAVR trials and those reported in TVT. In addition, these data suggest that comparison between hospitals based on post-TAVR stroke rates is potentially problematic.


Assuntos
Estenose da Valva Aórtica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Michigan/epidemiologia , Teorema de Bayes , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Hospitais , Sistema de Registros , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
20.
J Thorac Cardiovasc Surg ; 165(6): 2011-2020.e5, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-34538638

RESUMO

BACKGROUND: Despite the rapid adoption of transcatheter aortic valve replacement since its approval, the frequency and outcomes of aortic valve reintervention after transcatheter aortic valve replacement are poorly understood. METHODS: Valve reinterventions, either surgical transcatheter aortic valve explantation or repeat transcatheter aortic valve replacement, between 2012 and 2019 were queried using the Society of Thoracic Surgeons Database and the Transcatheter Valve Therapy Registry through the Michigan Statewide quality collaborative. The reintervention frequency and clinical outcomes including observed-to-expected mortality ratio using Society of Thoracic Surgeons Predicted Risk of Mortality were reviewed. RESULTS: Among 9694 transcatheter aortic valve replacement recipients, a total of 87 patients (0.90%) received a reintervention, consisting of 34 transcatheter aortic valve explants and 53 repeat transcatheter aortic valve replacement procedures. The transcatheter aortic valve explant group demonstrated a higher Society of Thoracic Surgeons Predicted Risk of Mortality. Reintervention cases increased from 0 in 2012 and 2013 to 26 in 2019. The proportion of transcatheter aortic valve explants among all reinterventions increased and was 65% in 2019. Self-expandable devices had a higher reintervention rate than balloon-expandable devices secondary to a higher transcatheter aortic valve explant frequency (0.58% [23/3957] vs 0.19% [11/5737]; P = .001), whereas repeat transcatheter aortic valve replacement rates were similar (0.61% [24/3957] vs 0.51% [29/5737]; P = .51). Among patients with transcatheter aortic valve explants, contraindications to repeat transcatheter aortic valve replacement included unfavorable anatomy (75%), need for other cardiac surgery (29%), other structural issues by transcatheter aortic valve device (18%), and endocarditis (12%). For transcatheter aortic valve explant and repeat transcatheter aortic valve replacement, the 30-day mortality was 15% and 2% (P = .032) and the observed-to-expected mortality ratio was 1.8 and 0.3 (P = .018), respectively. CONCLUSIONS: Aortic valve reintervention remains rare but is increasing. The clinical impact of surgical device explantation was substantial, and the proportion of transcatheter aortic valve explants was significantly higher in patients with a self-expandable device.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...