Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 6: 32686, 2016 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-27604639

RESUMO

This study reports on a facile and economical method for the scalable synthesis of few-layered graphene sheets by the microwave-assisted functionalization. Herein, single-layered and few-layered graphene sheets were produced by dispersion and exfoliation of functionalized graphite in ethylene glycol. Thermal treatment was used to prepare pure graphene without functional groups, and the pure graphene was labeled as thermally-treated graphene (T-GR). The morphological and statistical studies about the distribution of the number of layers showed that more than 90% of the flakes of T-GR had less than two layers and about 84% of T-GR were single-layered. The microwave-assisted exfoliation approach presents us with a possibility for a mass production of graphene at low cost and great potentials in energy storage applications of graphene-based materials. Owing to unique surface chemistry, the T-GR demonstrates an excellent energy storage performance, and the electrochemical capacitance is much higher than that of the other carbon-based nanostructures. The nanoscopic porous morphology of the T-GR-based electrodes made a significant contribution in increasing the BET surface as well as the specific capacitance of graphene. T-GR, with a capacitance of 354.1 Fg(-1) at 5 mVs(-1) and 264 Fg(-1) at 100 mVs(-1), exhibits excellent performance as a supercapacitor.

2.
Sci Rep ; 5: 17503, 2015 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-26643279

RESUMO

Capacitive deionization (CDI) is a promising procedure for removing various charged ionic species from brackish water. The performance of graphene-based material in capacitive deionization is lower than the expectation of the industry, so highly-crumpled, few-layered graphene (HCG) and highly-crumpled nitrogen-doped graphene (HCNDG) with high surface area have been introduced as promising candidates for CDI electrodes. Thus, HCG and HCNDG were prepared by exfoliation of graphite in the presence of liquid-phase, microwave-assisted methods. An industrially-scalable, cost-effective, and simple approach was employed to synthesize HCG and HCNDG, resulting in few-layered graphene and nitrogen-doped graphene with large specific surface area. Then, HCG and HCNDG were utilized for manufacturing a new class of carbon nanostructure-based electrodes for use in large-scale CDI equipment. The electrosorption results indicated that both the HCG and HCNDG have fairly large specific surface areas, indicating their huge potential for capacitive deionization applications.

3.
J Biomed Mater Res A ; 103(9): 2959-65, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25690431

RESUMO

One of the novel applications of the nanostructures is the modification and development of membranes for hemocompatibility of hemodialysis. The toxicity and hemocompatibility of Ag nanoparticles and arginine-treated multiwalled carbon nanotubes (MWNT-Arg) and possibility of their application in membrane technology are investigated here. MWNT-Arg is prepared by amidation reactions, followed by characterization by FTIR spectroscopy, Raman spectroscopy, and thermogravimetric analysis. The results showed a good hemocompatibility and the hemolytic rates in the presence of both MWNT-Arg and Ag nanoparticles. The hemolytic rate of Ag nanoparticles was lower than that of MWNT-Arg. In vivo study revealed that Ag nanoparticle and MWNT-Arg decreased Hematocrit and mean number of red blood cells (RBC) statistically at concentration of 100 µg mL(-1) . The mean decrease of RBC and Hematocrit for Ag nanoparticles (18% for Hematocrit and 5.8 × 1,000,000/µL) was more than MWNT-Arg (20% for Hematocrit and 6 × 1000000/µL). In addition, MWNT-Arg and Ag nanoparticles had a direct influence on the White Blood Cell (WBC) drop. Regarding both nanostructures, although the number of WBC increased in initial concentration, it decreased significantly at the concentration of 100 µg mL(-1) . It is worth mentioning that the toxicity of Ag nanoparticle on WBC was higher than that of MWNT-Arg. Because of potent antimicrobial activity and relative hemocompatibility, MWNT-Arg could be considered as a new candidate for biomedical applications in the future especially for hemodialysis membranes.


Assuntos
Células Sanguíneas/efeitos dos fármacos , Nanopartículas Metálicas/toxicidade , Nanotubos de Carbono/toxicidade , Animais , Anti-Infecciosos/química , Anti-Infecciosos/toxicidade , Arginina/química , Arginina/toxicidade , Materiais Biocompatíveis/química , Materiais Biocompatíveis/toxicidade , Contagem de Eritrócitos , Hematócrito , Hemólise/efeitos dos fármacos , Técnicas In Vitro , Contagem de Leucócitos , Teste de Materiais , Membranas Artificiais , Nanopartículas Metálicas/química , Nanotubos de Carbono/química , Ratos , Diálise Renal/efeitos adversos , Diálise Renal/instrumentação , Prata/química , Prata/toxicidade
4.
Indoor Air ; 19(6): 500-10, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19719535

RESUMO

UNLABELLED: This article presents findings of the thermal comfort study in hospitals. A field survey was conducted to investigate the temperature range for thermal comfort in hospitals in the tropics. Thermal acceptability assessment was conducted to examine whether the hospitals in the tropics met the ASHRAE Standard-55 80% acceptability criteria. A total of 114 occupants in four hospitals were involved in the study. The results of the field study revealed that only 44% of the examined locations met the comfort criteria specified in ASHRAE Standard 55. The survey also examined the predicted percentage of dissatisfied in the hospitals. The results showed that 49% of the occupants were satisfied with the thermal environments in the hospitals. The field survey analysis revealed that the neutral temperature for Malaysian hospitals was 26.4 degrees C. The comfort temperature range that satisfied 90% of the occupants in the space was in the range of 25.3-28.2 degrees C. The results from the field study suggested that a higher comfort temperature was required for Malaysians in hospital environments compared with the temperature criteria specified in ASHRAE Standard (2003). In addition, the significant deviation between actual mean vote and predicted mean vote (PMV) strongly implied that PMV could not be applied without errors in hospitals in the tropics. PRACTICAL IMPLICATIONS: The new findings on thermal comfort temperature range in hospitals in the tropics could be used as an important guide for building services engineers and researchers who are intending to minimize energy usage in heating, ventilating and air conditioning systems in hospitals operating in the tropics with acceptable thermal comfort level and to improve the performance and well-being of its workers.


Assuntos
Ar Condicionado/normas , Hospitais/normas , Recursos Humanos em Hospital/psicologia , Clima Tropical , Feminino , Humanos , Malásia , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...