Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Interv Neuroradiol ; : 15910199241242170, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38576409

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device (MicroVention, Tustin, CA, USA) has an excellent safety profile. While major complications such as device malposition and migration are rare, they can have serious consequences if not addressed promptly. Our case series describes the safety and efficacy of Amplatz goose neck microsnare device (Medtronic in Irvine, CA, USA) in endovascular retrieval of a detached WEB device. METHODS: We retrospectively reviewed six consecutive patients who underwent endovascular WEB retrieval using Amplatz microsnare device between March 2012 and December 2022. RESULTS: All six WEB devices were successfully retrieved either directly from the aneurysm sac due to device malpositioning or from a distal branch following device migration. None of the patients experienced intra-operative aneurysm perforation, arterial dissection, or vasospasm attributable to the process of WEB extraction. Five out of six patients (83.3%) had a good functional outcome (mRS 0-1) upon discharge from the hospital and at 24 months. CONCLUSION: Our experience suggests that detached WEB devices can be safely retrieved using an Amplatz microsnare. Apart from addressing device migration, direct removal of an undersized or malpositioned WEB from the aneurysm sac appears to be a safe option that can be considered when all other rescue techniques have been exhausted.

2.
AJNR Am J Neuroradiol ; 45(6): 731-736, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38290739

RESUMO

BACKGROUND AND PURPOSE: The Woven EndoBridge (WEB) system has established itself as a safe and effective option for managing wide-neck bifurcation aneurysms. Addressing aneurysms with a greater height than width using conventional WEB-sizing methods has proved ineffective due to the inherent configuration of the devices. To overcome this limitation, we propose an intuitive approach that involves swapping the width and height dimensions of the aneurysm to determine the appropriate WEB size. MATERIALS AND METHODS: A retrospective analysis was conducted on patients undergoing WEB embolization at a single neuroscience center from March 2013 to February 2023. RESULTS: Twenty-five eligible aneurysms were identified, with the height dimension exceeding the width by an average of 2.33 mm (ranging from 1.4 to 4.5 mm). Of these, 20 cases adhered to the recommended sizing technique, resulting in a 100% success rate of adequate occlusion (14/20 complete occlusion, 6/20 proximal recess filling). In contrast, the outcomes for the remaining 5 cases that did not follow the proposed sizing method were less favorable (P < .05). Among these, 4 cases treated with undersized WEBs showed neck remnants during follow-up, and 1 patient who received an oversized WEB required device replacement during the same procedure. CONCLUSIONS: The simple sizing method we proposed for treating taller-than-wide aneurysms has demonstrated promising results, allowing the WEB system to address twice the original size range of treatable aneurysms. Further research with a larger sample size is recommended.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Adulto , Resultado do Tratamento , Angiografia Cerebral
3.
Stroke ; 53(9): 2770-2778, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35506384

RESUMO

BACKGROUND: The impact on clinical outcomes of patient selection using perfusion imaging for endovascular thrombectomy (EVT) in patients with acute ischemic stroke presenting beyond 6 hours from onset remains undetermined in routine clinical practice. METHODS: Patients from a national stroke registry that underwent EVT selected with or without perfusion imaging (noncontrast computed tomography/computed tomography angiography) in the early (<6 hours) and late (6-24 hours) time windows, between October 2015 and March 2020, were compared. The primary outcome was the ordinal shift in the modified Rankin Scale score at hospital discharge. Other outcomes included functional independence (modified Rankin Scale score ≤2) and in-hospital mortality, symptomatic intracerebral hemorrhage, successful reperfusion (Thrombolysis in Cerebral Infarction score 2b-3), early neurological deterioration, futile recanalization (modified Rankin Scale score 4-6 despite successful reperfusion) and procedural time metrics. Multivariable analyses were performed, adjusted for age, sex, baseline stroke severity, prestroke disability, intravenous thrombolysis, mode of anesthesia (Model 1) and including EVT technique, balloon guide catheter, and center (Model 2). RESULTS: We included 4249 patients, 3203 in the early window (593 with perfusion versus 2610 without perfusion) and 1046 in the late window (378 with perfusion versus 668 without perfusion). Within the late window, patients with perfusion imaging had a shift towards better functional outcome at discharge compared with those without perfusion imaging (adjusted common odds ratio [OR], 1.45 [95% CI, 1.16-1.83]; P=0.001). There was no significant difference in functional independence (29.3% with perfusion versus 24.8% without; P=0.210) or in the safety outcome measures of symptomatic intracerebral hemorrhage (P=0.53) and in-hospital mortality (10.6% with perfusion versus 14.3% without; P=0.053). In the early time window, patients with perfusion imaging had significantly improved odds of functional outcome (adjusted common OR, 1.51 [95% CI, 1.28-1.78]; P=0.0001) and functional independence (41.6% versus 33.6%, adjusted OR, 1.31 [95% CI, 1.08-1.59]; P=0.006). Perfusion imaging was associated with lower odds of futile recanalization in both time windows (late: adjusted OR, 0.70 [95% CI, 0.50-0.97]; P=0.034; early: adjusted OR, 0.80 [95% CI, 0.65-0.99]; P=0.047). CONCLUSIONS: In this real-world study, acquisition of perfusion imaging for EVT was associated with improvement in functional disability in the early and late time windows compared with nonperfusion neuroimaging. These indirect comparisons should be interpreted with caution while awaiting confirmatory data from prospective randomized trials.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Hemorragia Cerebral , Procedimentos Endovasculares/métodos , Humanos , Imagem de Perfusão , Estudos Prospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...