Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Head Trauma Rehabil ; 23(4): 197-208, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18650764

RESUMO

OBJECTIVE: To investigate the relation of white matter integrity using diffusion tensor imaging (DTI) to cognitive and functional outcome of moderate to severe traumatic brain injury (TBI) in children. DESIGN: Prospective observational study of children who had sustained moderate to severe TBI and a comparison group of children who had sustained orthopedic injury (OI). PARTICIPANTS: Thirty-two children who had sustained moderate to severe TBI and 36 children with OI were studied. METHODS: Fiber tracking analysis of DTI acquired at 3-month postinjury and assessment of global outcome and cognitive function within 2 weeks of brain imaging. Global outcome was assessed using the Glasgow Outcome Scale and the Flanker task was used to measure cognitive processing speed and resistance to interference. RESULTS: Fractional anisotropy and apparent diffusion coefficient values differentiated the groups and both cognitive and functional outcome measures were related to the DTI findings. Dissociations were present wherein the relation of Fractional anisotropy to cognitive performance differed between the TBI and OI groups. A DTI composite measure of white matter integrity was related to global outcome in the children with TBI. CONCLUSIONS: DTI is sensitive to white matter injury at 3 months following moderate to severe TBI in children, including brain regions that appear normal on conventional magnetic resonance imaging. DTI measures reflecting diffusion of water parallel and perpendicular to white matter tracts as calculated by fiber tracking analysis are related to global outcome, cognitive processing speed, and speed of resolving interference in children with moderate to severe TBI. Longitudinal data are needed to determine whether these relations between DTI and neurobehavioral outcome of TBI in children persist at longer follow-up intervals.


Assuntos
Lesões Encefálicas/patologia , Encéfalo/patologia , Transtornos Cognitivos/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Fibras Nervosas Mielinizadas/patologia , Adolescente , Lesões Encefálicas/reabilitação , Estudos de Casos e Controles , Criança , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino
2.
AJNR Am J Neuroradiol ; 26(6): 1583-6, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15956534

RESUMO

Lissencephaly is a rare brain malformation characterized histologically by arrested neuronal migration such that the brain resembles that of a fetus before 23-24 weeks gestation. We studied a neonate with lissencephaly by using diffusion tensor imaging and suggest the dysplastic densely cellular layer IV is visible as a band of anisotropic diffusion. Fiber tracking showed lack of connectivity between the cortex and deep white matter and an abnormal limbic system.


Assuntos
Encéfalo/anormalidades , Encéfalo/patologia , Imageamento por Ressonância Magnética , Humanos , Recém-Nascido , Masculino
3.
Radiology ; 235(3): 1011-7, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15860678

RESUMO

PURPOSE: To prospectively compare two-dimensional (2D) time-of-flight cerebral magnetic resonance (MR) venography with gadolinium-enhanced three-dimensional (3D) gradient-echo cerebral MR venography in children. MATERIALS AND METHODS: This investigation had investigational review board approval and was Health Insurance Portability and Accountability Act compliant; parental informed consent was obtained. Thirty-seven patients (20 boys, 17 girls) who ranged in age from 4 days to 15 years underwent 2D and 3D MR venography. Two pediatric neuroradiologists compared the visibility of the superior sagittal, straight, transverse, and sigmoid sinuses and the internal jugular veins on images obtained with the two sequences. RESULTS: In 17 (46%) of the 37 patients, the sequences were equivalent in terms of their depiction of venous anatomy. In 19 (51%) of the 37 patients, 3D MR venography was superior to 2D MR venography. Suboptimal enhancement of veins occurred in one (3%) patient at 3D MR venography. Venous anomalies suggested at 2D MR venography but not present at 3D MR venography included flow gaps in the nondominant transverse sinuses of four patients, unilateral transverse sinus atresia in eight, and a narrowed superior sagittal sinus in two. Two-dimensional MR venography results failed to reveal a persistent falcine sinus associated with straight sinus atresia in one patient and suggested transverse sinus thrombosis in two patients in whom 3D MR venography results were normal. Additionally, the extent of dural thrombosis was overestimated at 2D MR venography in one patient. As compared with 3D MR venography, 2D MR venography failed to reveal sigmoid sinus stenosis in one patient and poorly depicted posterior fossa dural sinus anatomy in two patients with dural arteriovenous fistula. CONCLUSION: Three-dimensional MR venography is often superior to 2D MR venography in the delineation of major cerebral venous structures in children. Most of the artifactual loss of vascular signal seen with the use of 2D MR venography occurred in nondominant transverse sinuses.


Assuntos
Veias Cerebrais/patologia , Transtornos Cerebrovasculares/patologia , Meios de Contraste , Gadolínio DTPA , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Flebografia/métodos , Estudos Prospectivos
4.
AJNR Am J Neuroradiol ; 26(1): 50-5, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15661699

RESUMO

BACKGROUND AND PURPOSE: Little is known about age-related changes in posterior fossa venous anatomy on 2D time-of-flight MR venography (MRV) or about artifacts that limit its accuracy in diagnosing venous occlusive disease. We evaluated pediatric appearances of posterior fossa venous drainage. METHODS: One hundred and eight children with normal MR imaging or minimal congenital anomalies underwent 2D MRV. Transverse sinus dominance and absence and the presence of an occipital sinus were correlated with age. Venous structure conspicuity was compared on source and maximum intensity projection images. RESULTS: Right, left, and codominance of the transverse sinus, respectively, was as follows: at < 25 months, 37%, 21%, and 42%; 25 months to 5 years, 35%, 30%, 35%; and > or =6 years, 50%, 16%, 34%. Transverse sinus dominance was not related to age between the three groups (P=.58, chi-square contingency), but some relationship was observed when patients <6 years were compared to those > or =6 years (P=.032). Chi-square trends showed a mildly positive correlation between age and an absent transverse sinus (P=.026) and a decreasing trend in the presence of an occipital sinus with age (P=.038). Saturation effects due to in-plane/slow flow were worse in patients <25 months; effects in the transverse sinuses or internal jugular veins were miminized with coronal or axial imaging, respectively. CONCLUSION: 2D TOF MRV shows age-related changes in venous anatomy. Caution should be used before posterior fossa venous occlusive disease is diagnosed on the basis of signal intensity loss, especially in neonates and young infants.


Assuntos
Veias Cerebrais/anormalidades , Processamento de Imagem Assistida por Computador/métodos , Malformações Arteriovenosas Intracranianas/diagnóstico , Angiografia por Ressonância Magnética/métodos , Flebografia/métodos , Adolescente , Velocidade do Fluxo Sanguíneo/fisiologia , Veias Cerebrais/patologia , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Cavidades Cranianas/anormalidades , Cavidades Cranianas/patologia , Deficiências do Desenvolvimento/diagnóstico , Dominância Cerebral/fisiologia , Epilepsia/diagnóstico , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Estatística como Assunto
5.
Radiology ; 226(3): 731-8, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12601183

RESUMO

PURPOSE: To determine the contrast agent behavior of gadolinium-based (extracellular and albumin-binding) and manganese-based contrast media for late-enhancement imaging of myocardial infarction. MATERIALS AND METHODS: Coronary ligation was performed in 30 rats, and they were serially imaged with segmented inversion-recovery gradient-echo magnetic resonance (MR) imaging (repetition time msec/echo time msec/inversion time msec [fixed], 5.2/2.5/430; flip angle, 15 degrees ) during 1 hour after administration of contrast media by using a 1.5-T MR unit. Serial measurements of the longitudinal relaxation were performed by using the Look-Locker approach (repetition time msec/echo time msec, 1,000/3.5; flip angle, 10 degrees ). Detection and size of infarction were evaluated at each time point and compared with end-point histologic findings. RESULTS: For all manganese-based media, the contrast agent cleared from the blood pool rapidly. Manganese-based contrast media allowed precise labeling of viable cardiomyocytes within 30 minutes, and the labeling persisted for at least 1 hour. Accumulation of gadoversetamide in the infarct area was apparent after 5 minutes, and the peak contrast-to-noise ratio (CNR) between infarct and myocardium was comparable to the peak CNR of manganese-based contrast agents. Extracellular gadopentetate dimeglumine provided excellent infarct detection but a small imaging window for precise sizing of the infarct if a fixed inversion time of 430 msec was used. Albumin-binding gadolinium-based contrast media provided a longer imaging window, but infarct size was overestimated because of the nonspecific distribution of the unbound gadolinium agent. CONCLUSION: When extracellular gadolinium-based agents are used for infarct size measurement, imaging parameters and timing are important because the kinetics of both normal and irreversibly injured myocardium must be considered. Manganese-based agents are highly specific and less sensitive to timing for infarct size determination, but further studies are required to determine if they are feasible for human use.


Assuntos
Meios de Contraste/farmacocinética , Imageamento por Ressonância Magnética/métodos , Compostos de Manganês/farmacocinética , Infarto do Miocárdio/diagnóstico , Compostos Organometálicos/farmacocinética , Análise de Variância , Animais , Modelos Animais de Doenças , Masculino , Imagens de Fantasmas , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...