J Interv Card Electrophysiol ; 54(1): 49-54, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30187250

RESUMO

BACKGROUND: Before subcutaneous implantable cardioverter defibrillator (S-ICD) implantation, the adequacy of sensing is required to be verified through surface ECG screening. Our objective was to determine whether S-ICD can be considered as a supplementary therapy in patients who are receiving biventricular (BIV) pacing. METHODS: We evaluated 48 patients with BIV devices to determine S-ICD candidacy during BIV, left ventricular (LV), right ventricular (RV) pacing, and intrinsic conduction (left bundle branch block-LBBB) by using an automated screening tool. Eligibility was defined by the presence of at least one appropriate vector in the supine and standing positions. RESULTS: Eligibility was verified during BIV pacing in 34 (71%) patients. In patients screened-out, QRS duration was longer (p = 0.035) and ischemic cardiomyopathy was more frequent (p = 0.027). LV-only pacing was associated with a lower passing rate (46%) (p < 0.001 versus BIV). The LBBB QRS morphology during inhibited ventricular pacing was acceptable in 51% of patients. The QRS generated by RV pacing was acceptable in 25% of patients. In patients who passed the screening test during BIV, the QRS was not acceptable in 76% during RV pacing (i.e., accidental loss of LV capture). The concomitant adequacy during inhibited ventricular pacing (i.e., possible intrinsic conduction) was not assessed in 40% of patients. CONCLUSIONS: S-ICD may be a supplemental therapy in the majority of CRT patients. Standard BIV pacing should be preferred to the LV-only pacing mode, as it is more frequently associated with adequacy of S-ICD sensing. Spontaneous LBBB and RV-paced QRS morphologies are frequently inadequate. Therefore, in patients selected for concomitant S-ICD and CRT implantation, accidental loss of LV capture or possible intrinsic conduction must be prevented.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/mortalidade , Terapia de Ressincronização Cardíaca/métodos , Distribuição de Qui-Quadrado , Estudos de Coortes , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Humanos , Itália , Masculino , Seleção de Pacientes , Prognóstico , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...