Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann R Coll Surg Engl ; 102(7): e167-e169, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32347740

RESUMO

Lymphadenopathy is a common presentation in surgical assessment units and has numerous differential diagnoses. In one-stop breast clinics, its discovery often raises concerns of malignancy. This case report focuses on the case of a 33-year-old pregnant woman presenting to the breast clinic with a right axillary lump, which was found to be the result of toxoplasmosis.


Assuntos
Linfadenopatia/etiologia , Complicações Parasitárias na Gravidez , Toxoplasmose/complicações , Adulto , Axila , Biópsia , Diagnóstico Diferencial , Feminino , Humanos , Linfonodos/patologia , Linfadenopatia/diagnóstico , Gravidez , Toxoplasmose/diagnóstico , Ultrassonografia Mamária/métodos
2.
Ann R Coll Surg Engl ; 96(5): 352-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24992418

RESUMO

INTRODUCTION: The surgical Apgar score (SAS) can predict 30-day major complications or death after surgery. Studies have validated the score in different patient populations and suggest it should be used to objectively guide postoperative care. We aimed to see whether using the SAS in a decisive approach in a future randomised controlled trial (RCT) would be likely to demonstrate an effect on postoperative care and clinical outcome. METHODS: A total of 143 adults undergoing general/vascular surgery in 9 National Health Service hospitals were recruited to a pilot single blinded RCT and the data for 139 of these were analysed. Participants were randomised to a control group with standard postoperative care or to an intervention group with care influenced (but not mandated) by the SAS (decisive approach). The notional primary outcome was 30-day major complications or death. RESULTS: Incidence of major complications was similar in both groups (control: 20/69 [29%], intervention: 23/70 [33%], p=0.622). Immediate admissions to the critical care unit was higher in the intervention group, especially in the SAS 0-4 subgroup (4/6 vs 2/7) although this was not statistically significant (p=0.310). Validity was also confirmed in area under the curve (AUC) analysis (AUC: 0.77). CONCLUSIONS: This pilot study found that a future RCT to investigate the effect of using the SAS in a decisive approach may demonstrate a difference in postoperative care. However, significant changes to the design are needed if differences in clinical outcome are to be achieved reliably. These would include a wider array of postoperative interventions implemented using a quality improvement approach in a stepped wedge cluster design with blinded collection of outcome data.


Assuntos
Exame Físico/métodos , Cuidados Pós-Operatórios/métodos , Adulto , Área Sob a Curva , Humanos , Projetos Piloto , Complicações Pós-Operatórias/terapia
3.
Acta Chir Belg ; 114(1): 31-3, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24720135

RESUMO

BACKGROUND: We evaluated the concordance between peri-areolar blue dye and peri-incisional radiotracer injections for axillary sentinel node mapping of patients with the history of previous breast lesion excisional biopsy. METHODS: 80 patients with the history of previous excisional biopsy of the breast lesions were included. All patients received two injections of 99mTc-antimony sulfide colloid in both ends of incision line in an intradermal fashion. 2 mL patient blue V dye was injection to all patients in the peri-areolar area of the index quadrant after induction of anesthesia. All blue or hot nodes were harvested as sentinel lymph nodes. RESULTS: At least one sentinel node could be detected during surgery in 79 patients. In total 94 sentinel nodes were detected. All detected sentinel nodes were hot. In three patients sentinel nodes were detected by gamma probe but not blue dye. The tumor location in all of these patients was in the upper lateral quadrant and the incision line was extended into the axillary tail of the breast in all of them. 91 out of 94 sentinel nodes were stained blue, which amounts to 95.8% concordance between blue dye and radiotracer on a per node analysis. CONCLUSIONS: Single peri-areolar injection in the index quadrant would suffice for sentinel node mapping of patients with history of excisional biopsy. Care should be taken in patients with large excisional biopsy in the extreme proximity to axilla.


Assuntos
Neoplasias da Mama/diagnóstico , Corantes , Linfonodos/patologia , Compostos Radiofarmacêuticos , Biópsia de Linfonodo Sentinela/métodos , Axila , Neoplasias da Mama/metabolismo , Neoplasias da Mama/cirurgia , Corantes/administração & dosagem , Feminino , Seguimentos , Humanos , Injeções , Linfonodos/cirurgia , Metástase Linfática , Compostos Radiofarmacêuticos/administração & dosagem , Estudos Retrospectivos , Corantes de Rosanilina
4.
Br J Surg ; 97(8): 1232-9, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20593429

RESUMO

BACKGROUND: Intraoperative diagnosis of sentinel node metastases enables an immediate decision to proceed to axillary lymph node dissection, avoiding a second operation in node-positive women with breast cancer. METHODS: An optical scanner was developed that interrogated the cut surface of bivalved, but otherwise unprocessed, sentinel lymph nodes with pulses of white light by elastic scattering spectroscopy (ESS). The scattered light underwent spectral analysis, and individual spectra were initially correlated with conventional histology to develop a diagnostic algorithm. This algorithm was used to create false colour-coded maps of scans from an independent set of nodes, and the optimal criteria for discriminating between normal and cancer spectra were defined statistically. RESULTS: The discriminant algorithm was developed from a training set of 2989 spectra obtained from 30 metastatic and 331 normal nodes. Subsequent scans from 129 independent nodes were analysed. The scanner detected macrometastases (larger than 2 mm) with a sensitivity of 76 per cent (69 per cent including micrometastases) and specificity of 96 per cent. CONCLUSION: In this proof-of-principle study, the ESS results were comparable with current intraoperative diagnostic techniques of lymph node assessment.


Assuntos
Neoplasias da Mama/diagnóstico , Diagnóstico por Computador/métodos , Cuidados Intraoperatórios/métodos , Metástase Linfática/diagnóstico , Biópsia de Linfonodo Sentinela , Análise Espectral/métodos , Algoritmos , Neoplasias da Mama/cirurgia , Desenho de Equipamento , Feminino , Humanos , Cuidados Intraoperatórios/instrumentação , Excisão de Linfonodo , Curva ROC , Espalhamento de Radiação , Sensibilidade e Especificidade , Análise Espectral/instrumentação
5.
Eur J Surg Oncol ; 35(12): 1250-6, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19540710

RESUMO

INTRODUCTION: Sentinel lymph node (SLN) biopsy is the evolving standard of care for the management of early breast cancer. Accurate identification of the SLN is paramount for success of this procedure. Various techniques are described for SLN identification, but the superficial injection techniques, advocated by the UK National Training Programme (NEW START), are validated, reproducible and rapid. Pre-operative lymphoscintigraphy provides a road map for the surgeon and requires a reporting template. METHODS: As one of the NEW START training institutions in the UK practising this technique, we reviewed a mature series of 100 unselected, consecutive SLN lymphoscintigraphy procedures. We correlated the imaging, operative and pathology findings and have provided technical details of the technique and a template for reporting SLN lymphoscintigrams. RESULTS: The SLN localisation rate was 99% with one failed imaging. Seven patients required delayed imaging. The mean activity of the radiocolloid injected was 14.4MBq (range 8.3-23 MBq). The SLNs were visualised in the ipsilateral axilla in 98 images, intramammary in 3, and internal mammary in 1. A mean of 1.35 nodes were classified as 'True' SLNs on imaging criteria. Intra-operatively, a mean of 1.91 SLNs were excised. 32 of 116 hot and blue nodes, 7 of 15 only blue nodes, 13 of 47 only hot and 7 of 13 parasentinel nodes harboured metastases. CONCLUSION: The NEW START recommended, combined superficial injection techniques, have high localisation rates. Pre-operative sentinel node imaging is recommended and a template for reporting is provided.


Assuntos
Neoplasias da Mama/patologia , Metástase Linfática/diagnóstico por imagem , Compostos Radiofarmacêuticos/administração & dosagem , Biópsia de Linfonodo Sentinela/métodos , Agregado de Albumina Marcado com Tecnécio Tc 99m/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Corantes/administração & dosagem , Feminino , Humanos , Injeções/métodos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática/patologia , Pessoa de Meia-Idade , Cintilografia , Corantes de Rosanilina/administração & dosagem , Reino Unido
6.
Br J Surg ; 93(5): 572-6, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16550634

RESUMO

BACKGROUND: Intraoperative detection of sentinel lymph node (SLN) metastases enables the surgeon to take an immediate decision to proceed to completion axillary lymph node dissection (ALND). The aim of this study was to determine the accuracy of touch imprint cytology (TIC) for the diagnosis of SLN metastases in sentinel nodes from women with breast cancer. METHODS: Touch imprints from 235 sentinel nodes in 133 women with breast cancer were diagnosed by cytopathology and compared with definitive histopathology results. After a feasibility study, a real-time study was performed with the surgeon proceeding to ALND based on the TIC diagnosis. The clinical opinion of the operating surgeon as to whether the SLN appeared to contain metastases was recorded, as was the time taken for the result to be available. RESULTS: TIC detected metastases with a sensitivity of 81.1 per cent and a specificity of 100 per cent. False-negative TIC diagnoses were associated with micrometastases and lobular carcinoma. The majority of false-negative diagnoses were due to sampling rather than interpretation errors. Clinical assessment of sentinel nodes had a sensitivity of 64.3 per cent and a specificity of 87.6 per cent. CONCLUSION: TIC is feasible and enables the rapid diagnosis of SLN metastases with an acceptable accuracy for clinical use in ductal carcinoma of the breast.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Biópsia de Linfonodo Sentinela , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/cirurgia , Reações Falso-Negativas , Feminino , Humanos , Cuidados Intraoperatórios/métodos , Excisão de Linfonodo , Metástase Linfática/patologia , Projetos Piloto , Sensibilidade e Especificidade , Biópsia de Linfonodo Sentinela/normas
7.
Eur J Surg Oncol ; 31(2): 134-40, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15698728

RESUMO

BACKGROUND: Sentinel node biopsy is becoming the staging investigation of choice for early breast cancer. Optimal identification of the sentinel node requires the utilization of a radionuclide in combination with blue dye. Gamma probe guided surgery is a skill that is currently unfamiliar to many surgeons. Appropriate training within the surgical skills laboratory could play a major role in the widespread implementation of this technique, but no suitable model currently exists for this purpose. AIM: To develop a realistic phantom for the teaching and practice of the core new skills required of a surgeon to perform gamma probe guided sentinel node biopsy in breast cancer. METHODS: We describe the development of our sentinel node biopsy simulator which consists of a torso with its arm extended in an operating position. The replaceable breast and axilla are constructed from a thermoplastic elastomer gel, which has similar physical and radiation attenuation properties to that of human tissue. Radionuclide injection sites and radioactive sentinel nodes are simulated by hollow blue coloured PVC beads filled with Technetium-99m. The model allows demonstration and practice of injection techniques, imaging techniques and gamma probe guided removal of sentinel nodes. CONCLUSION: We believe that training for sentinel node biopsy should begin in the surgical skills laboratory. The model we have developed is able to provide an accurate simulation of all new practical skills required for accurate sentinel node identification. It is an important aid to training in the sentinel lymph node biopsy procedure for breast carcinoma.


Assuntos
Neoplasias da Mama/patologia , Biópsia de Linfonodo Sentinela/educação , Ensino , Axila , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Linfonodos/patologia , Intensificação de Imagem Radiográfica/métodos , Intensificação de Imagem Radiográfica/normas , Biópsia de Linfonodo Sentinela/métodos , Biópsia de Linfonodo Sentinela/normas , Ensino/métodos , Ensino/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...