Health Phys ; 127(2): 276-286, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38394553

RESUMO

ABSTRACT: In the widespread use of medical cyclotrons for isotope production, radiological and economic consequences related to the decommissioning of particle accelerators are often neglected. However, decommissioning regulation and its related procedures always demand efforts and costs that can unexpectedly impact on budgets. The magnitude of this impact depends strongly on the residual radioactivity of the accelerator and of the vault, and more specifically on the kind and activity concentration of residual radionuclides. This work reports and discusses a case study that analyzes in detail the characterization activities needed for optimized management of the decommissioning of a medical cyclotron vault. In particular, this paper presents the activities carried out for assessing the activity concentrations and for guiding the disposal of the cyclotron vault of the Italian National Cancer Institute of Milano (INT). An unshielded 17 MeV cyclotron vault was characterized by high resolution gamma-ray spectrometry both in-situ and in-laboratory on extracted samples. Monte Carlo simulations were also carried out to assess the overall distribution of activation in the vault. After a few months from the final shutdown of the accelerator, activity concentrations in the concrete walls due to neutron activation exceeded the clearance levels in many regions, especially close to the cyclotron target. Due to the relatively long half-lives of some radionuclides, a time interval of about 20 y after the end of bombardment is necessary for achieving clearance in some critical positions. Far from the target or in positions shielded by the cyclotron, activation levels were below the clearance level. The comparison between Monte Carlo simulations and experimental results shows a good agreement. The in-situ measurements, simpler and economically advantageous, cannot completely replace the destructive measurements, but they may limit the number of required samples and consequently the decommissioning costs. The methodology described and the results obtained demonstrated that it is possible to obtain accurate estimations of activity concentrations with cheap and quick in-situ measurements if the concentration profile in-depth inside the wall is well known. This profile can be obtained either experimentally or numerically through suitably validated Monte Carlo simulations.


Assuntos
Ciclotrons , Método de Monte Carlo , Itália , Radioisótopos/análise , Resíduos Radioativos/análise , Humanos
3.
Phys Med ; 116: 103166, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37926641

RESUMO

The European Council Directive 2013/59/Euratom (BSS Directive) includes optimisation of treatment with radiotherapeutic procedures based on patient dosimetry and verification of the absorbed doses delivered. The present policy statement summarises aspects of three directives relating to the therapeutic use of radiopharmaceuticals and medical devices, and outlines the steps needed for implementation of patient dosimetry for radioactive drugs. To support the transition from administrations of fixed activities to personalised treatments based on patient-specific dosimetry, EFOMP presents a number of recommendations including: increased networking between centres and disciplines to support data collection and development of codes-of-practice; resourcing to support an infrastructure that permits routine patient dosimetry; research funding to support investigation into individualised treatments; inter-disciplinary training and education programmes; and support for investigator led clinical trials. Close collaborations between the medical physicist and responsible practitioner are encouraged to develop a similar pathway as is routine for external beam radiotherapy and brachytherapy. EFOMP's policy is to promote the roles and responsibilities of medical physics throughout Europe in the development of molecular radiotherapy to ensure patient benefit. As the BSS directive is adopted throughout Europe, unprecedented opportunities arise to develop informed treatments that will mitigate the risks of under- or over-treatments.


Assuntos
Medicina Nuclear , Humanos , Radiometria , Políticas , Europa (Continente)
5.
Eur J Nucl Med Mol Imaging ; 50(2): 328-343, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36114872

RESUMO

PURPOSE: In light of recently published clinical reports and trials, the TheraSphere Global Dosimetry Steering Committee (DSC) reconvened to review new data and to update previously published clinical and dosimetric recommendations for the treatment of hepatocellular carcinoma (HCC). METHODS: The TheraSphere Global DSC is comprised of health care providers across multiple disciplines involved in the treatment of HCC with yttrium-90 (Y-90) glass microsphere-based transarterial radioembolization (TARE). Literature published between January 2019 and September 2021 was reviewed, discussed, and adjudicated by the Delphi method. Recommendations included in this updated document incorporate both the results of the literature review and the expert opinion and experience of members of the committee. RESULTS: Committee discussion and consensus led to the expansion of recommendations to apply to five common clinical scenarios in patients with HCC to support more individualized efficacious treatment with Y-90 glass microspheres. Existing clinical scenarios were updated to reflect recent developments in dosimetry approaches and broader treatment paradigms evolving for patients presenting with HCC. CONCLUSION: Updated consensus recommendations are provided to guide clinical and dosimetric approaches for the use of Y-90 glass microsphere TARE in HCC, accounting for disease presentation, tumor biology, and treatment intent.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Radioisótopos de Ítrio/uso terapêutico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamento farmacológico , Microesferas , Compostos Radiofarmacêuticos/uso terapêutico , Embolização Terapêutica/métodos , Vidro
6.
Eur J Nucl Med Mol Imaging ; 50(3): 921-928, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36282299

RESUMO

BACKGROUND: A textbook outcome (TO) is a composite indicator covering the entire intervention process in order to reflect the "ideal" intervention and be a surrogate for patient important outcomes. Selective internal radiation therapy (SIRT) is a complex multidisciplinary and multistep intervention facing the challenge of standardization. This expert opinion-based study aimed to define a TO for SIRT of hepatocellular carcinoma. METHODS: This study involved two steps: (1) the steering committee (4 interventional radiologists) first developed an extensive list of possible relevant items reflecting an optimal SIRT intervention based on a literature review and (2) then conducted an international and multidisciplinary survey which resulted in the final TO. This survey was online, from February to July 2021, and consisted three consecutive rounds with predefined settings. Experts were identified by contacting senior authors of randomized trials, large observational studies, or studies on quality improvement in SIRT. This study was strictly academic. RESULTS: A total of 50 items were included in the first round of the survey. A total of 29/40 experts (73%) responded, including 23 interventional radiologists (79%), three nuclear medicine physicians (10%), two hepatologists, and one oncologist, from 11 countries spanning three continents. The final TO consisted 11 parameters across six domains ("pre-intervention workup," "tumor targeting and dosimetry," "intervention," "post-90Y imaging," "length of hospital stay," and "complications"). Of these, all but one were applied in the institutions of > 80% of experts. CONCLUSIONS: This multidimensional indicator is a comprehensive standardization tool, suitable for routine care, clinical round, and research.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamento farmacológico , Radiometria , Radioisótopos de Ítrio/uso terapêutico
8.
Cancers (Basel) ; 14(4)2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35205712

RESUMO

In this confirmatory study, we tested if a calculation that included the non-uniformity of dose deposition through a voxel-based dosimetric variable Ψ was able to improve the dose-response agreement with respect to the mean absorbed dose D. We performed dosimetry with 99mTc-MAA SPECT/CT and 90Y-PET/CT in 86 patients treated 8 instead of 4 days after the reference date with 2.8 times more 90Y glass microspheres/GBq than in our previous study. The lesion-by-lesion response was assessed with the mRECIST method and with an experimental densitometric criterion. A total of 106 lesions were studied. Considering Ψ as a prognostic response marker, having no Ψ provided a significantly higher AUC than D. The correlation, t-test, and AUC values were statistically significant only with the densitometric method and only with post-therapy dosimetry. In comparison with our previous study, the dose-response correlation and AUC values were poorer (maximum r = 0.43, R2 = 0.14, maximal AUC = 0.71), and the efficacy at a high dose did not reach 100%. The expected advantages of voxel dosimetry were nullified by the correlation between any Ψ and D due to the limited image spatial resolution. The lower AUC and efficacy may be explained by the mega-clustering effect triggered by the higher number of microspheres/GBq injected on day 8.

9.
Tumori ; 108(4): 315-325, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34405748

RESUMO

OBJECTIVE: To give an updated overview on clinical aspects and survival effects of lutetium-177-prostate-specific membrane antigen (PSMA) (177Lu-PSMA) radioligand therapy (RLT), a novel treatment option for patients with metastatic castration-resistant prostate cancer (mCRPC). METHODS: PubMed/MEDLINE database was searched for relevant articles published up to March 2021. The search was restricted to English-language articles. RESULTS: Current evidence from the literature consistently demonstrated the efficacy, safety, and survival benefit of 177Lu-PSMA RLT in mCRPC. However, current data rely predominantly on retrospective analyses, showing heterogeneity of patient population and treatment protocols. More recently, results from the first randomized phase II study (TheraP) demonstrated that 177Lu-PMSA therapy significantly improved prostate-specific antigen response rate (66% vs 37%) and had fewer grade 3/4 adverse events when compared to cabazitaxel in patients with docetaxel-pretreated, progressive mCRPC. This review is intended to provide an updated overview of treatment protocols and responses, toxicity profile, and survival effects of 177Lu-PSMA RLT. CONCLUSIONS: 177Lu-PSMA RLT has emerged as a promising targeted treatment in mCRPC. It is currently applied in compassionate use programs and following exhaustion of approved therapies. Crucial for establishing this treatment in routine clinical management will be the results of the phase III VISION trial, which may confirm the encouraging patient outcomes reported to date.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Ensaios Clínicos Fase II como Assunto , Dipeptídeos/uso terapêutico , Compostos Heterocíclicos com 1 Anel/uso terapêutico , Humanos , Masculino , Antígeno Prostático Específico , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Neoplasias de Próstata Resistentes à Castração/radioterapia , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Resultado do Tratamento
10.
EJNMMI Phys ; 8(1): 77, 2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34767102

RESUMO

The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in 90Y microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient-relative calibration method for activity quantification.The identity of 99mTc albumin macro-aggregates (MAA) and 90Y microsphere biodistribution is also assumed. The large observed discrepancies in some patients between 99mTc-MAA predictions and actual 90Y microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments.Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected 99mTc-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and 90Y TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected 99mTc-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative 90Y bremsstrahlung SPECT can be used if dedicated correction methods are available.The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.

11.
Phys Med ; 89: 317-326, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34583307

RESUMO

This recommendation by the Italian Associations of Nuclear Medicine (AIMN) and Medical Physics (AIFM) focuses on the dosimetric optimization of Nuclear Medicine Therapy (NMT) as clearly requested by the article 56 of the EURATOM Directive 2013/59 and its consequent implementation in article 158 in the Italian Law n. 101/2020. However, this statement must deal with scientific and methodological limits that still exist and, above all, with the currently available limited resources. This paper addresses these specific issues. It distinguishes among many possible kinds of NMT. For each type, dosimetric optimization is recommended or considered optional, according to the general criteria adopted in any human choice, i.e. a check of technical feasibility first, followed by a cost/benefit argument. The classification of therapies as standardized or non-standardized is presented. This is based on the complexity of the type of pathology, on the variability of the treatment outcome, and on the risks involved. According to the present document, which was officially delivered to Italian Health Ministry as necessary interpretation of the law, a therapeutic team can, in science and consciousness, overcome the indications of posology, to optimize and tailoring a treatment with dosimetry, on the basis of published national or international data or guidelines, without need of an Ethics Committee approval. Data collected in this way will provide additional evidence about optimal dosimetric reference values. As conclusion, a formal appeal is made to the European and National regulatory agencies for pharmaceuticals to obtain the official acknowledgment of this principle.


Assuntos
Medicina Nuclear , União Europeia , Humanos , Itália , Física , Radiometria
12.
Phys Med ; 75: 85-91, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32559650

RESUMO

The reconstruction algorithms implemented on PET/CT scanners offer gain in activity recovery of small lesions at an extent that is not full known yet. METHODS: A cylindrical phantom with warm background and hot spheres filled with a 68Ge epoxy was acquired with four non-state-solid-detectors PET/CT scanners: mCT, Ingenuity TF, Discovery 710, and IQ. Images were reconstructed switching on and off time-of-flight (TOF), point spread function (PSF) modelling, and Bayesian penalised likelihood (BPL). Images were reconstructed with the default parameters recommended by the manufacturers. The recovery coefficient (RCmax), defined as the ratio of the measured maximum activity concentration in each sphere and the actual one, and the coefficient of variation (CoVBAC) defined as the ratio of the standard deviation and the average of background activity concentration were measured. RESULTS: While with IR alone, complete recovery of the activity concentration is achieved down to the 22 mm diameter's sphere, with TOF, TOF + PSF and BPL it is achieved down to the 17 mm diameter one. At smaller dimensions, the difference among the various studied reconstruction algorithms is substantial for the 13- and 17-mm diameters' spheres for all scanners and for all reconstructions with a considerable gain in RCmax when PSF and BPL are used. At 10 mm diameter's sphere the difference among the algorithms is significantly reduced, except for BPL which still guarantees a gain in RCmax.


Assuntos
Algoritmos , Germânio , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Radioisótopos , Razão Sinal-Ruído
13.
EJNMMI Phys ; 7(1): 15, 2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-32144574

RESUMO

The purpose of the EANM Dosimetry Committee Series on "Standard Operational Procedures for Dosimetry" (SOP) is to provide advice to scientists and clinicians on how to perform patient-specific absorbed dose assessments. This SOP describes image and data acquisition parameters and dosimetry calculations to determine the absorbed doses delivered to whole-body, tumour and normal organs following a therapeutic administration of 131I mIBG for the treatment of neuroblastoma or adult neuroendocrine tumours. Recommendations are based on evidence in recent literature where available and on expert opinion within the community. This SOP is intended to promote standardisation of practice within the community and as such is based on the facilities and expertise that should be available to any centre able to perform specialised treatments with radiopharmaceuticals and patient-specific dosimetry. A clinical example is given to demonstrate the application of the absorbed dose calculations.

16.
Eur J Nucl Med Mol Imaging ; 46(8): 1695-1704, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31098749

RESUMO

The TheraSphere Global Dosimetry Steering Committee was formed in 2017 by BTG International to review existing data and address gaps in knowledge related to dosimetry. This committee is comprised of health care providers with diverse areas of expertise and perspectives on radiation dosimetry. The goal of these recommendations is to optimize glass microspheres radiation therapy for hepatocellular carcinoma while accounting for variables including disease presentation, tumour vascularity, liver function, and curative/palliative intent. The recommendations aim to unify glass microsphere users behind standardized dosimetry methodology that is simple, reproducible and supported by clinical data, with the overarching goal of improving clinical outcomes and advancing the knowledge of dosimetry.


Assuntos
Conferências de Consenso como Assunto , Guias de Prática Clínica como Assunto , Radiometria/normas , Compostos Radiofarmacêuticos/normas , Radioterapia/normas , Radioisótopos de Ítrio/normas , Carcinoma Hepatocelular/radioterapia , Humanos , Neoplasias Hepáticas/radioterapia , Microesferas , Compostos Radiofarmacêuticos/uso terapêutico , Radioterapia/métodos , Dosagem Radioterapêutica , Radioisótopos de Ítrio/uso terapêutico
17.
Eur J Nucl Med Mol Imaging ; 45(13): 2426-2441, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29785514

RESUMO

PURPOSE: Peptide receptor radionuclide therapy (PRRT) with 90Y-labelled and 177Lu-labelled peptides is an effective strategy for the treatment of metastatic/nonresectable neuroendocrine tumours (NETs). Dosimetry provides important information useful for optimizing PRRT with individualized regimens to reduce toxicity and increase tumour responses. However, this strategy is not applied in routine clinical practice, despite the fact that several dosimetric studies have demonstrated significant dose-effect correlations for normal organ toxicity and tumour response that can better guide therapy planning. The present study reviews the key relationships and the radiobiological models available in the literature with the aim of providing evidence that optimization of PRRT is feasible through the implementation of dosimetry. METHODS: The MEDLINE database was searched combining specific keywords. Original studies published in the English language reporting dose-effect outcomes in patients treated with PRRT were chosen. RESULTS: Nine of 126 studies were selected from PubMed, and a further five were added manually, reporting on 590 patients. The studies were analysed and are discussed in terms of weak and strong elements of correlations. CONCLUSION: Several studies provided evidence of clinical benefit from the implementation of dosimetry in PRRT, indicating the potential contribution of this approach to reducing severe toxicity and/or reducing undertreatment that commonly occurs. Prospective trials, possibly multicentre, with larger numbers of patients undergoing quantitative dosimetry and with standardized methodologies should be carried out to definitively provide robust predictive paradigms to establish effective tailored PRRT.


Assuntos
Lutécio/efeitos adversos , Lutécio/uso terapêutico , Medicina de Precisão/métodos , Radioisótopos/efeitos adversos , Radioisótopos/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Receptores de Peptídeos/metabolismo , Radioisótopos de Ítrio/efeitos adversos , Radioisótopos de Ítrio/uso terapêutico , Humanos , Dosagem Radioterapêutica
18.
Med Phys ; 45(4): 1684-1698, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29383733

RESUMO

PURPOSE: To investigate the clinical implication of performing pre-treatment dosimetry for 90 Y-microspheres liver radioembolization on 99m Tc-MAA SPECT images reconstructed without attenuation or scatter correction and quantified with the patient relative calibration methodology. METHODS: Twenty-five patients treated with SIR-Spheres® at Istituto Europeo di Oncologia and 31 patients treated with TheraSphere® at Istituto Nazionale Tumori were considered. For each acquired 99m Tc-MAA SPECT, four reconstructions were performed: with attenuation and scatter correction (AC_SC), only attenuation (AC_NoSC), only scatter (NoAC_SC) and without corrections (NoAC_NoSC). Absorbed dose maps were calculated from the activity maps, quantified applying the patient relative calibration to the SPECT images. Whole Liver (WL) and Tumor (T) regions were drawn on CT images. Injected Liver (IL) region was defined including the voxels receiving absorbed dose >3.8 Gy/GBq. Whole Healthy Liver (WHL) and Healthy Injected Liver (HIL) regions were obtained as WHL = WL - T and HIL = IL - T. Average absorbed dose to WHL and HIL were calculated, and the injection activity was derived following each Institute's procedure. The values obtained from AC_NoSC, NoAC_SC and NoAC_NoSC images were compared to the reference value suggested by AC_SC images using Bland-Altman analysis and Wilcoxon paired test (5% significance threshold). Absorbed-dose maps were compared to the reference map (AC_SC) in global terms using the Voxel Normalized Mean Square Error (%VNMSE), and at voxel level by calculating for each voxel the normalized difference with the reference value. The uncertainty affecting absorbed dose at voxel level was accounted for in the comparison; to this purpose, the voxel counts fluctuation due to Poisson and reconstruction noise was estimated from SPECT images of a water phantom acquired and reconstructed as patient images. RESULTS: NoAC_SC images lead to activity prescriptions not significantly different from the reference AC_SC images; the individual differences (<0.1 GBq for all IEO patients, <0.6 GBq for all but one INT patients) were comparable to the uncertainty affecting activity measurement. AC_NoSC and NoAC_NoSC images, instead, yielded significantly different activity prescriptions and wider 95% confidence intervals in the Bland-Altman analysis. Concerning the absorbed dose map, AC_NoSC images had the smallest %VNMSE value and the highest fraction of voxels differing less than 2 standard deviations from AC_SC. CONCLUSIONS: The patient relative calibration methodology can compensate for the missing attenuation correction when performing healthy liver pre-treatment dosimetry: safe treatments can be planned even on NoAC_SC images, suggesting activities comparable to AC_SC images. Scatter correction is recommended due to its heavy impact on healthy liver dosimetry.


Assuntos
Embolização Terapêutica , Processamento de Imagem Assistida por Computador , Fígado/diagnóstico por imagem , Fígado/efeitos da radiação , Espalhamento de Radiação , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Calibragem , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Estudos Retrospectivos , Razão Sinal-Ruído , Incerteza
19.
J Hepatol ; 68(4): 724-732, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29331342

RESUMO

BACKGROUND & AIMS: Yttrium-90 transarterial radioembolization (TARE) has shown promising efficacy in the treatment of patients with hepatocellular carcinoma (HCC), associated with portal vein tumor thrombus (PVTT). The aim of this study is to identify prognostic factors for survival in patients with HCC and PVTT undergoing TARE, and build a prognostic classification for these patients. METHODS: This is a single center retrospective study conducted over six years (2010-2015), on consecutive patients undergoing TARE. Patients were included if they met the following criteria: presence of at least one measurable HCC, presence of PVTT not occluding the main portal trunk, absence of extrahepatic metastases, Child-Pugh score within B7, Eastern Cooperative Oncology Group performance status 0-1. Uni- and multivariable analysis was used to explore the variables that showed an independent relationship with survival. A prognostic score was then derived, and three prognostic categories were identified. RESULTS: A total of 120 patients were included in the study. Median overall survival (OS) was 14.1 months (95% CI 10.7-17.5) and median progression-free survival (PFS) was 6.5 months (95% CI 3.8-9.2). The only variables independently correlated with OS were bilirubin, extension of PVTT and tumor burden. Three prognostic categories were identified: favourable prognosis (0 points), intermediate prognosis (2-3 points) and dismal prognosis (>3 points). Median OS in the three categories was 32.2 months, 14.9 months and 7.8 months respectively (p <0.0001). PFS (p = 0.045) and the risk of liver decompensation (p <0.0001) also significantly differed along the same prognostic categories. CONCLUSIONS: Radioembolization with Yttrium-90 is an effective therapy for patients with HCC and PVTT. The proposed prognostic stratification may help to better identify good candidates for the treatment, and those for whom TARE may be futile. LAY SUMMARY: Yttrium-90 transarterial radioembolization (TARE) is a microembolic procedure that minimizes alterations to hepatic arterial flow, and thus can be safely performed in patients with hepatocellular carcinoma (HCC) and portal vein tumor thrombus (PVTT). In this study, we retrospectively evaluated the independent predictors of long-term outcomes in patients with HCC and PVTT treated with TARE. Bilirubin level, extension of PVTT and tumor burden were independently related to post-treatment survival: the combination of these factors allowed us to build a prognostic stratification that may help to better identify good candidates for the treatment, and those for whom TARE may be futile.


Assuntos
Carcinoma Hepatocelular/terapia , Embolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Veia Porta/patologia , Radioisótopos de Ítrio/uso terapêutico , Idoso , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Prognóstico , Estudos Retrospectivos
20.
EJNMMI Phys ; 4(1): 28, 2017 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-29199391

RESUMO

BACKGROUND: Currently, the implementation of dosimetry in molecular radiotherapy (MRT) is not well investigated, and in view of the Council Directive (2013/59/Euratom), there is a need to understand the current availability of dosimetry-based MRT in clinical practice and research studies. The aim of this study was to assess the current practice of MRT and dosimetry across European countries. METHODS: An electronic questionnaire was distributed to European countries. This addressed 18 explicitly considered therapies, and for each therapy, a similar set of questions were included. Questions covered the number of patients and treatments during 2015, involvement of medical specialties and medical physicists, implementation of absorbed dose planning, post-therapy imaging and dosimetry, and the basis of therapy prescription. RESULTS: Responses were obtained from 26 countries and 208 hospitals, administering in total 42,853 treatments. The most common therapies were 131I-NaI for benign thyroid diseases and thyroid ablation of adults. The involvement of a medical physicist (mean over all 18 therapies) was reported to be either minority or never by 32% of the responders. The percentage of responders that reported that dosimetry was included on an always/majority basis differed between the therapies and showed a median value of 36%. The highest percentages were obtained for 177Lu-PSMA therapy (100%), 90Y microspheres of glass (84%) and resin (82%), 131I-mIBG for neuroblastoma (59%), and 131I-NaI for benign thyroid diseases (54%). The majority of therapies were prescribed based on fixed-activity protocols. The highest number of absorbed-dose based prescriptions were reported for 90Y microsphere treatments in the liver (64% and 96% of responses for resin and glass, respectively), 131I-NaI treatment of benign thyroid diseases (38% of responses), and for 131I-mIBG treatment of neuroblastoma (18% of responses). CONCLUSIONS: There is a wide variation in MRT practice across Europe and for different therapies, including the extent of medical-physicist involvement and the implementation of dosimetry-guided treatments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...