Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 33(6): 681-6, 2010 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20230479

RESUMO

BACKGROUND: Cryoablation with 4- and 6-mm tip ablation catheters has been demonstrated to be safe and effective in the treatment of atrioventricular nodal reentrant tachycardia (AVNRT) in pediatric patients, albeit with a higher rate of clinical recurrence. Limited information is available regarding efficacy, mid-term outcomes, and complications related to the use of the 8-mm Freezor Max Cryoablation catheter (Medtronic, Minneapolis, MN, USA) in pediatric patients. METHODS: We performed a retrospective review of all pediatric patients with normal cardiac anatomy who underwent an ablation procedure for treatment of AVNRT using the 8-mm tip Cryoablation catheter at three large pediatric academic arrhythmia centers. RESULTS: Cryoablation with an 8-mm tip catheter was performed in 77 patients for treatment of AVNRT (female n = 40 [52%], age 14.8 +/- 2.2 years, weight 62.0 +/- 13.9 kg). Initial procedural success was achieved in 69 patients (69/76, 91%). Transient second- or third-degree atrioventricular (AV) block was noted in five patients (6.5%). There was no permanent AV block. Of the patients successfully ablated with Cryotherapy, there were two recurrences (2/70, 2.8%) over a follow-up of 11.6 +/- 3.3 months. CONCLUSION: Cryoablation with an 8-mm tip ablation catheter is both safe and effective with a low risk of recurrence for the treatment of AVNRT in pediatric patients.


Assuntos
Criocirurgia/métodos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adolescente , Bloqueio Atrioventricular/etiologia , Criança , Feminino , Humanos , Masculino , Recidiva , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/complicações , Resultado do Tratamento
2.
Pacing Clin Electrophysiol ; 31(9): 1152-9, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18834467

RESUMO

BACKGROUND: Recurrence rates of atrioventricular nodal reentry tachycardia (AVNRT) after cryoablation continue to remain high despite excellent initial success rates. Our objective was to evaluate the clinical outcomes of cryoablation for AVNRT with the 4-mm and 6-mm tip cryoablation catheters in a young population and to elicit predictors of arrhythmia recurrence. METHODS: We retrospectively reviewed all patients who underwent cryoablation for AVNRT at the UCSF/Stanford Pediatric Arrhythmia Center from January 2004 to February 2007. RESULTS: One hundred fifty-four patients (age 13.7 years (3.2-24.4)) underwent cryoablation for AVNRT of which 144 patients had inducible AVNRT (123 sustained and 21 nonsustained) and 10 had presumed AVNRT. Initial success was achieved in 95% (146/154), with no difference between the 4-mm (93%) and 6-mm (98%) cryoablation catheter tips (P = 0.15). There was no permanent atrioventricular (AV) block. Transient third-degree AV block occurred in nine patients (6%), with no difference between the 4-mm (4%) and 6-mm (9%) tip (P = 0.13). AVNRT recurrence was documented in 14% in a median time of 2.5 months (0.25-20). Recurrences were lower with the 6-mm (9%) versus the 4-mm (18%) tip, but this did not reach statistical significance (P = 0.16). With univariate analysis, a longer fluoroscopy time was the only significant factor associated with recurrence. Multivariate analysis failed to identify any significant predictor of AVNRT recurrence. CONCLUSION: Outcomes of cryoablation for AVNRT continue to be good without the complication of AV block. We could not identify any specific parameter associated with AVNRT recurrence. Further improvements in cryoablation technique will be necessary to reduce recurrences.


Assuntos
Criocirurgia/estatística & dados numéricos , Medição de Risco/métodos , Taquicardia por Reentrada no Nó Atrioventricular/epidemiologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adolescente , California/epidemiologia , Criança , Pré-Escolar , Feminino , Humanos , Incidência , Masculino , Prognóstico , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Resultado do Tratamento , Adulto Jovem
3.
J Cardiovasc Electrophysiol ; 17(6): 638-44, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16836714

RESUMO

INTRODUCTION: Dual atrioventricular (AV) nodal physiology, defined as an AH jump > or =50 msec with a 10 msec decrease in A1A2, is the substrate for atrioventricular nodal reentrant tachycardia (AVNRT) and yet it is present in a minority of pediatric patients with AVNRT. Our objective was to characterize dual AV nodal physiology as it pertains to a pediatric population. METHODS/RESULTS: We retrospectively reviewed invasive electrophysiology studies in 92 patients with AVNRT (age12.1 +/- 3.7 yrs) and in 46 controls without AVNRT (age 13.3 +/- 3.7 yrs). Diagnoses in controls: syncope (N = 31), palpitations (N = 6), atrial flutter (N = 3), history of atrial tachycardia with no inducible arrhythmia (N = 3), and ventricular tachycardia (N = 3). General anesthesia was used in 49% of AVNRT and 52% of controls, P = 0.86. There were no differences in PR, AH, HV, or AV block cycle length. With A1A2 atrial stimulation, AVNRT patients had a significantly longer maximum AH achieved (324 +/- 104 msec vs 255 +/- 67 msec, P = 0.001), and a shorter AVNERP (276 +/- 49 msec vs 313 +/- 68 msec P = 0.0005). An AH jump > or =50 msec was found in 42% of AVNRT versus 30% of controls (P = 0.2). Using a ROC graph we found that an AH jump of any size is a poor predictor of AVNRT. With atrial overdrive pacing, PR > or = RR was seen more commonly in AVNRT versus controls, (55/91(60%) vs 6/46 (13%) P = 0.000). CONCLUSIONS: Neither the common definition of dual AV nodes or redefining an AH jump as some value <50 msec are reliable methods to define dual AV nodes or to predict AVNRT in pediatric patients. PR > or = RR is a relatively good predictor of AVNRT.


Assuntos
Nó Atrioventricular/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Adolescente , Criança , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Fatores de Tempo
4.
Heart Rhythm ; 3(5): 557-63, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16648061

RESUMO

BACKGROUND: Cryoablation for treatment of atrioventricular nodal reentrant tachycardia (AVNRT) is safe and efficacious. Information on the effects of cryoablation on atrioventricular (AV) nodal conduction is limited. OBJECTIVES: The purpose of this study was to evaluate the effects of cryoablation on AV nodal conduction in pediatric patients with AVNRT. METHODS: We retrospectively analyzed electrophysiologic studies before and after successful cryoablation. Patients were divided into two groups: group 1 (n = 22, age 14 +/- 3 years) had baseline discontinuous atrial-to-His interval (AH) conduction curves; and group 2 (n = 13, age 12 +/- 4 years, P = .054) had continuous curves. RESULTS: At baseline, group 1 had longer measurements of maximal AH with A1A2, AV nodal effective refractory period, and AV block cycle length. Postcryoablation, both group 1 and group 2 showed decreases in maximal AH with A1A2 pacing or atrial overdrive pacing and in the finding of PR > or = RR with atrial overdrive pacing (group 1: 55% vs 5%, P < .001; group 2: 69% vs 0%, P < .001). A significant increase in overall AV effective refractory period and a decrease in AV block cycle length were found in group 1 but not group 2. Fifty percent of group 1 patients had complete abolition of slow pathway conduction. CONCLUSION: Successful cryoablation for treatment of AVNRT is associated with a reduction in PR > or = RR and with decreases in maximal AH with A1A2 pacing or atrial overdrive pacing. Further study is needed to determine the usefulness of these parameters for assessment of ablation efficacy or as proxies for AVNRT inducibility.


Assuntos
Criocirurgia , Técnicas Eletrofisiológicas Cardíacas , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adolescente , Função Atrial , Fascículo Atrioventricular/fisiopatologia , Fascículo Atrioventricular/cirurgia , Criança , Feminino , Seguimentos , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/cirurgia , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
5.
Heart Rhythm ; 3(5): 564-70, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16648062

RESUMO

BACKGROUND: Initial reports have shown cryoablation to be safe and efficacious for treatment of atrioventricular nodal reentrant tachycardia (AVNRT). No direct comparisons of cryoablation vs radiofrequency (RF) catheter ablation in pediatric patients have been made. OBJECTIVES: The purpose of this study was to compare the outcomes of cryothermal vs RF catheter ablation for treatment of AVNRT in pediatric patients. METHODS: We retrospectively reviewed consecutive ablation procedures for treatment of AVNRT at a single arrhythmia center. The RF group consisted of patients who underwent RF ablation from 2002 until cryothermy became available. The cryoablation group consisted of patients who underwent cryothermal ablation from 2004 to 2005. The groups were compared for procedural and electrophysiologic outcomes. RESULTS: RF (n = 60, age 14 +/- 4 years) and cryoablation (n = 57, age 14 +/- 4 years) groups had similar demographic and baseline parameters. Procedural times were shorter in the RF group (RF ablation 112 +/- 31 minutes vs cryoablation 148 +/- 46 minutes, P < .001). Fluoroscopy times were comparable (RF ablation 21 +/- 15 minutes vs cryoablation 20 +/- 13 minutes, P = .77). In an intention-to-treat analysis, success of the procedure was 100% for RF ablation and 95% for cryoablation (P = .11). No permanent AV block occurred in either group. Recurrence rates were higher for the cryoablation group, but this did not reach statistical significance (RF ablation 2% vs cryoablation 8%, P = .19). CONCLUSION: Cryoablation appears to be similar to RF for ablation of AVNRT with respect to short-term efficacy and safety of the procedure in a pediatric population. Recurrence rates are higher with cryoablation.


Assuntos
Ablação por Cateter , Criocirurgia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adolescente , Ablação por Cateter/efeitos adversos , Criança , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Técnicas Eletrofisiológicas Cardíacas , Feminino , Bloqueio Cardíaco/etiologia , Humanos , Masculino , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 13(3): 203-9, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11942583

RESUMO

INTRODUCTION: Prior studies in adults have shown significant shortening of the fast pathway effective refractory period after successful slow pathway ablation. As differences between adults and children exist in other characteristics of AV nodal reentrant tachycardia (AVNRT), we sought to characterize the effect of slow pathway ablation or modification in a multicenter study of pediatric patients. METHODS AND RESULTS: Data from procedures in pediatric patients were gathered retrospectively from five institutions. Entry criteria were age <21 years, typical AVNRT inducible with/without isoproterenol infusion, and attempted slow pathway ablation or modification. Dual AV nodal pathways were defined as those with > or =50 msec jump in A2-H2 with a 10-msec decrease in A1-A2. Successful ablation was defined as elimination of AVNRT inducibility. A total of 159 patients (age 4.4 to 21 years, mean 13.1) were studied and had attempted slow pathway ablation. AVNRT was inducible in the baseline state in 74 (47%) of 159 patients and with isoproterenol in the remainder. Dual AV nodal pathways were noted in 98 (62%) of 159 patients in the baseline state. Ablation was successful in 154 (97%) of 159 patients. In patients with dual AV nodal pathways and successful slow pathway ablation, the mean fast pathway effective refractory period was 343+/-68 msec before ablation and 263+/-64 msec after ablation. Mean decrease in the fast pathway effective refractory period was 81+/-82 msec (P < 0.0001) and was not explained by changes in autonomic tone, as measured by changes in sinus cycle length during the ablation procedure. Electrophysiologic measurements were correlated with age. Fast pathway effective refractory period was related to age both before (P = 0.0044) and after ablation (P < 0.0001). AV block cycle length was related to age both before (P = 0.0005) and after ablation (P < 0.0001). However, in dual AV nodal pathway patients, the magnitude of change in the fast pathway effective refractory period after ablation was not related to age. CONCLUSION: Lack of clear dual AV node physiology is common in pediatric patients with inducible AVNRT (38%). Fast pathway effective refractory period shortens substantially in response to slow pathway ablation. The magnitude of change is large compared with adult reports and is not completely explained by changes in autonomic tone. Prospective studies in children using autonomic blockade are needed.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adolescente , Adulto , Fatores Etários , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Humanos , Período Refratário Eletrofisiológico , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...