Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lab Chip ; 13(2): 288-96, 2013 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-23172232

RESUMO

A digitally programmable microfluidic Automaton consisting of a 2-dimensional array of pneumatically actuated microvalves is programmed to perform new multiscale mixing and sample processing operations. Large (µL-scale) volume processing operations are enabled by precise metering of multiple reagents within individual nL-scale valves followed by serial repetitive transfer to programmed locations in the array. A novel process exploiting new combining valve concepts is developed for continuous rapid and complete mixing of reagents in less than 800 ms. Mixing, transfer, storage, and rinsing operations are implemented combinatorially to achieve complex assay automation protocols. The practical utility of this technology is demonstrated by performing automated serial dilution for quantitative analysis as well as the first demonstration of on-chip fluorescent derivatization of biomarker targets (carboxylic acids) for microchip capillary electrophoresis on the Mars Organic Analyzer. A language is developed to describe how unit operations are combined to form a microfluidic program. Finally, this technology is used to develop a novel microfluidic 6-sample processor for combinatorial mixing of large sets (>2(6) unique combinations) of reagents. The digitally programmable microfluidic Automaton is a versatile programmable sample processor for a wide range of process volumes, for multiple samples, and for different types of analyses.


Assuntos
Automação , Técnicas Analíticas Microfluídicas/instrumentação , Ácidos Carboxílicos/química , Eletroforese Capilar , Desenho de Equipamento , Corantes Fluorescentes/química , Técnicas Analíticas Microfluídicas/métodos
2.
Astrobiology ; 11(6): 519-28, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21790324

RESUMO

The oxidizing surface chemistry on Mars argues that any comprehensive search for organic compounds indicative of life requires methods to analyze higher oxidation states of carbon with very low limits of detection. To address this goal, microchip capillary electrophoresis (µCE) methods were developed for analysis of carboxylic acids with the Mars Organic Analyzer (MOA). Fluorescent derivatization was achieved by activation with the water soluble 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) followed by reaction with Cascade Blue hydrazide in 30 mM borate, pH 3. A standard containing 12 carboxylic acids found in terrestrial life was successfully labeled and separated in 30 mM borate at pH 9.5, 20 °C by using the MOA CE system. Limits of detection were 5-10 nM for aliphatic monoacids, 20 nM for malic acid (diacid), and 230 nM for citric acid (triacid). Polyacid benzene derivatives containing 2, 3, 4, and 6 carboxyl groups were also analyzed. In particular, mellitic acid was successfully labeled and analyzed with a limit of detection of 300 nM (5 ppb). Analyses of carboxylic acids sampled from a lava tube cave and a hydrothermal area demonstrated the versatility and robustness of our method. This work establishes that the MOA can be used for sensitive analyses of a wide range of carboxylic acids in the search for extraterrestrial organic molecules.


Assuntos
Ácidos Carboxílicos/análise , Derivados de Benzeno/análise , Biomarcadores/análise , Eletroforese em Microchip , Etildimetilaminopropil Carbodi-Imida/química , Exobiologia/métodos , Hidrazinas/química , Marte , Pirenos/química
3.
Forensic Sci Int Genet ; 5(5): 484-92, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21071298

RESUMO

A twelve-lane capillary array electrophoresis (CAE) microsystem is developed that utilizes an efficient inline capture injection process together with the classical radial microfabricated capillary array electrophoresis (µCAE) format for high-sensitivity forensic short tandem repeat (STR) analysis. Biotin-labeled 9-plex STR amplicons are captured in a photopolymerized gel plug via the strong binding of streptavidin and biotin, followed by efficient washing and thermal release for CE separation. The analysis of 12 STR samples is completed in 30 min without any manual process intervention. A comparison between capture inline injection and conventional cross injection demonstrated at least 10-fold improvement in sensitivity. The limit-of-detection of the capture-CAE system was determined to be 35 haploid copies (17-18 diploid copies) of input DNA; this detection limit approaches the theoretical limits calculated using Poisson statistics and the spectral sensitivity of the instrument. To evaluate the capability of this microsystem for low-copy-number (LCN) analysis, three touch evidence samples recovered from unfired bullet cartridges in a pistol submerged in water for an hour were successfully analyzed, providing 53, 71, and 59% of the DNA profile. The high-throughput capture-CAE microsystem presented here provides a more robust and more sensitive platform for conventional as well as LCN and degraded DNA analysis.


Assuntos
Eletroforese em Microchip/métodos , Genética Forense , Repetições de Microssatélites , Haploidia , Humanos , Limite de Detecção
4.
Anal Chem ; 82(24): 10102-9, 2010 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-21114282

RESUMO

We developed a two-layer, four-channel polymerase chain reaction (PCR)-capillary electrophoresis microdevice that integrates nucleic acid amplification, sample cleanup and concentration, capillary electrophoretic separation, and detection for multiplex analysis of four human respiratory viral pathogens, influenza A, influenza B, coronavirus OC43, and human metapneumovirus. Biotinylated and fluorescently labeled double-stranded (ds) deoxyribonucleic acid (DNA) amplification products are generated in a 100 nL PCR reactor incorporating an integrated heater and a temperature sensor. After amplification, the products are captured and concentrated in a cross-linked acrylamide gel capture matrix copolymerized with acrydite-functionalized streptavidin-capture agents. Thermal dehybridization releases the fluorescently labeled DNA strand for capillary electrophoresis injection, separation, and detection. Using plasmid standards containing the viral genes of interest, each target can be detected starting from as few as 10 copies/reactor. When a two-step reverse transcription PCR amplification is employed, the device can detect ribonucleic acid (RNA) analogues of all four viral targets with detection limits in the range of 25-100 copies/reactor. The utility of the microdevice for analyzing samples from nasopharyngeal swabs is demonstrated. When size-based separation is combined with four-color detection, this platform provides excellent product discrimination, making it readily extendable to higher-order multiplex assays. This portable microsystem is also suitable for performing automated assays in point-of-care diagnostic applications.


Assuntos
Eletroforese Capilar/métodos , Reação em Cadeia da Polimerase/métodos , Sistema Respiratório/virologia , Coronavirus/isolamento & purificação , Eletroforese Capilar/instrumentação , Humanos , Vírus da Influenza A/isolamento & purificação , Vírus da Influenza B/isolamento & purificação , Metapneumovirus/isolamento & purificação , RNA Viral/análise
5.
Electrophoresis ; 31(22): 3642-9, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20967779

RESUMO

A microchip CE method is developed for the analysis of two oxidized forms of carbon, aldehydes and ketones, with the Mars Organic Analyzer (MOA). Fluorescent derivitization is achieved in ∼ 15 min by hydrazone formation with Cascade Blue hydrazide in 30 mM borate pH 5-6. The microchip CE separation and analysis method is optimized via separation in 30 mM borate buffer, pH 9.5, at 20°C. A carbonyl standard consisting of ten aldehydes and ketones found in extraterrestrial matter is successfully separated; the resulting LOD depends on the reactivity of the compound and range from 70 pM for formaldehyde to 2 µM for benzophenone. To explore the utility of this method for analyzing complex samples, analyses of several fermented beverages are conducted, identifying ten aldehydes and ketones ranging from 30 nM to 5 mM. A Martian regolith simulant sample, consisting of a basalt matrix spiked with soluble ions and acetone, is designed and analyzed, but acetone is found to have a limited detectable lifetime under simulant Martian conditions. This work establishes the capability of the MOA for studying aldehydes and ketones, a critical class of oxidized organic molecules of interest in planetary and in terrestrial environmental and health studies.


Assuntos
Aldeídos/análise , Biomarcadores/análise , Eletroforese em Microchip/métodos , Cetonas/análise , Modelos Químicos , Boratos/química , Exobiologia/métodos , Concentração de Íons de Hidrogênio , Marte , Compostos Organometálicos/química , Compostos Organofosforados/química , Solo/química
6.
Anal Chem ; 82(6): 2372-9, 2010 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-20151682

RESUMO

The Multichannel Mars Organic Analyzer (McMOA), a portable instrument for the sensitive microchip capillary electrophoresis (CE) analysis of organic compounds such as amino acid biomarkers and polycyclic aromatic hydrocarbons (PAHs), is developed. The instrument uses a four-layer microchip, containing eight CE analysis systems integrated with a microfluidic network for autonomous fluidic processing. The McMOA has improved optical components that integrate 405 nm laser excitation with a linear-scanning optical system capable of multichannel real-time fluorescence spectroscopic analysis. The instrumental limit of detection is 6 pM (glycine). Microfluidic programs are executed to perform the automated sequential analysis of an amine-containing sample in each channel as well as eight consecutive analyses of alternating samples on the same channel, demonstrating less than 1% cross-contamination. The McMOA is used to identify the unique fluorescence spectra of nine components in a PAH standard and then applied to the analysis of a sediment sample from Lake Erie. The presence of benzo[a]pyrene and perylene in this sample is confirmed, and a peak coeluting with anthanthrene is disqualified based on spectral analysis. The McMOA exploits lab-on-a-chip technologies to fully integrate complex autonomous operations demonstrating the facile engineering of microchip-CE platforms for the analysis of a wide variety of organic compounds in planetary exploration.


Assuntos
Aminoácidos/isolamento & purificação , Eletroforese em Microchip/instrumentação , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Biomarcadores/análise , Desenho de Equipamento , Limite de Detecção
7.
Astrobiology ; 9(9): 823-31, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19968460

RESUMO

The Mars Organic Analyzer (MOA) has enabled the sensitive detection of amino acid and amine biomarkers in laboratory standards and in a variety of field sample tests. However, the MOA is challenged when samples are extremely acidic and saline or contain polyvalent cations. Here, we have optimized the MOA analysis, sample labeling, and sample dilution buffers to handle such challenging samples more robustly. Higher ionic strength buffer systems with pK(a) values near pH 9 were developed to provide better buffering capacity and salt tolerance. The addition of ethylaminediaminetetraacetic acid (EDTA) ameliorates the negative effects of multivalent cations. The optimized protocol utilizes a 75 mM borate buffer (pH 9.5) for Pacific Blue labeling of amines and amino acids. After labeling, 50 mM (final concentration) EDTA is added to samples containing divalent cations to ameliorate their effects. This optimized protocol was used to successfully analyze amino acids in a saturated brine sample from Saline Valley, California, and a subcritical water extract of a highly acidic sample from the Río Tinto, Spain. This work expands the analytical capabilities of the MOA and increases its sensitivity and robustness for samples from extraterrestrial environments that may exhibit pH and salt extremes as well as metal ions.


Assuntos
Ácidos/análise , Aminas/análise , Aminoácidos/análise , Eletroforese Capilar/instrumentação , Meio Ambiente Extraterreno , Marte , Salinidade , Soluções Tampão , California , Cátions/química , Ácido Edético/química , Eletroforese Capilar/métodos , Cloreto de Magnésio/química , Padrões de Referência , Sais/química , Cloreto de Sódio/química , Espanha
8.
Electrophoresis ; 30(12): 2014-24, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19582705

RESUMO

In 2009, electrophoretically driven DNA separations in slab gels and capillaries have the sepia tones of an old-fashioned technology in the eyes of many, even while they remain ubiquitously used, fill a unique niche, and arguably have yet to reach their full potential. For comic relief, what is old becomes new again: agarose slab gel separations are used to prepare DNA samples for "next-gen" sequencing platforms (e.g. the Illumina and 454 machines) - dsDNA molecules within a certain size range are "cut out" of a gel and recovered for subsequent "massively parallel" pyrosequencing. In this review, we give a Barron lab perspective on how our comprehension of DNA migration mechanisms in electrophoresis has evolved, since the first reports of DNA separations by CE ( approximately 1989) until now, 20 years later. Fused-silica capillaries and borosilicate glass and plastic microchips quietly offer increasing capacities for fast (and even "ultra-fast"), efficient DNA separations. While the channel-by-channel scaling of both old and new electrophoresis platforms provides key flexibility, it requires each unique DNA sample to be prepared in its own micro or nanovolume. This Achilles' heel of electrophoresis technologies left an opening through which pooled sample, next-gen DNA sequencing technologies rushed. We shall see, over time, whether sharpening understanding of transitions in DNA migration modes in crosslinked gels, nanogel solutions, and uncrosslinked polymer solutions will allow electrophoretic DNA analysis technologies to flower again. Microchannel electrophoresis, after a quiet period of metamorphosis, may emerge sleeker and more powerful, to claim its own important niche applications.


Assuntos
DNA/química , Eletroforese Capilar/métodos , Eletroforese em Microchip/métodos , Acrilamidas/química , Resinas Acrílicas/química , Fenômenos Químicos , DNA de Cadeia Simples/isolamento & purificação , Interações Hidrofóbicas e Hidrofílicas , Processos Estocásticos , Viscosidade
9.
Anal Chem ; 81(7): 2537-44, 2009 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-19245228

RESUMO

The fluorescent amine reactive probe Pacific Blue succinimidyl ester (PB) is used for the detection of trace amounts of amines and amino acids by microchip capillary electrophoresis on the Mars Organic Analyzer (MOA). The spectral and chemical properties of PB provide a 200-fold increase in sensitivity and improved resolution compared to fluorescamine derivatization. With the use of cross injection and PB labeling, the MOA detected amino acids at concentrations as low as 75 pM (sub-parts-per-trillion). Micellar electrokinetic chromatography (MEKC) which separates PB-labeled amino acids by their hydrophobicity is also demonstrated. The optimized MEKC conditions (45 mM CHAPSO, pH 6 at 5 degrees C) effectively separated amines and 25 amino acids with enantiomeric resolution of alanine, serine, and citrulline. Samples from the Yungay Hills region in the Atacama Desert, Chile, and from the Murchison meteorite are successfully analyzed using both techniques, and amino acids are found in the parts-per-billion range. Abiotic amino acids such as beta-alanine and epsilon-aminocaprioc acid are detected along with several neutral and acidic amino acids in the Murchison sample. The Atacama Desert sample is found to contain homochiral L-alanine and L-serine indicating the presence of extant or recently extinct life.


Assuntos
Aminas/análise , Aminoácidos/análise , Eletroforese em Microchip/métodos , Corantes Fluorescentes/química , Marte , Succinimidas/química , Cromatografia , Clima Desértico , Exobiologia , Cinética , Meteoroides , Micelas , Sensibilidade e Especificidade
10.
Anal Chem ; 81(2): 790-6, 2009 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-19072718

RESUMO

The Mars Organic Analyzer (MOA), a portable microchip capillary electrophoresis (CE) instrument developed for sensitive amino acid analysis on Mars, is used to analyze laboratory standards and real-world samples for polycyclic aromatic hydrocarbons (PAHs). The microfabricated CE separation and analysis method for these hydrophobic analytes is optimized, resulting in a separation buffer consisting of 10 mM sulfobutylether-beta-cyclodextrin, 40 mM methyl-beta-cyclodextrin, 5 mM carbonate buffer at pH 10, 5 degrees C. A PAH standard consisting of seven PAHs found in extraterrestrial matter and two terrestrial PAHs is successfully baseline separated. Limits of detection for the components of the standard ranged from 2000 ppm to 6 ppb. Analysis of an environmental contamination standard from Lake Erie and of a hydrothermal vent chimney sample from the Guaymas Basin agreed with published composition. A Martian analogue sample from the Yungay Hills region of the Atacama Desert was analyzed and found to contain 9,10-diphenylanthracene, anthracene, anthanthrene, fluoranthene, perylene, and benzo[ghi]fluoranthene at ppm levels. This work establishes the viability of the MOA for detecting and analyzing PAHs in in situ planetary exploration.

11.
Electrophoresis ; 29(23): 4669-76, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19053064

RESUMO

By using a microfluidic electrophoresis platform to perform DNA sequencing, genomic information can be obtained more quickly and affordably than the currently employed capillary array electrophoresis instruments. Previous research in our group has shown that physically cross-linked, hydrophobically modified polyacrylamide matrices separate dsDNA more effectively than linear polyacrylamide (LPA) solutions. Expanding upon this work, we have synthesized a series of LPA-co-dihexylacrylamide block copolymers specifically designed to electrophoretically sequence ssDNA quickly and efficiently on a microfluidic device. By incorporating very small amounts of N,N-dihexylacrylamide, a hydrophobic monomer, these copolymer solutions achieved up to approximately 10% increases in average DNA sequencing read length over LPA homopolymer solutions of matched molar mass. Additionally, the inclusion of the small amount of hydrophobe does not significantly increase the polymer solution viscosities, relative to LPA solutions, so that channel loading times between the copolymers and the homopolymers are similar. The resulting polymer solutions are capable of providing enhanced sequencing separations in a short period of time without compromising the ability to rapidly load and unload the matrix from a microfluidic device.


Assuntos
Eletroforese em Microchip/métodos , Análise de Sequência de DNA/métodos , Resinas Acrílicas/síntese química , Resinas Acrílicas/química , DNA de Cadeia Simples/química , DNA de Cadeia Simples/genética , Humanos , Interações Hidrofóbicas e Hidrofílicas , Microscopia de Fluorescência , Reologia , Viscosidade
12.
J Forensic Sci ; 53(4): 828-37, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18540973

RESUMO

Miniaturization of capillary electrophoresis onto a microchip for forensic short tandem repeat analysis is the initial step in the process of producing a fully integrated and automated analysis system. A prototype of the Berkeley microfabricated capillary array electrophoresis device was installed at the Virginia Department of Forensic Science for testing. Instrument performance was verified by PowerPlex 16 System profiling of single source, sensitivity series, mixture, and casework samples. Mock sexual assault samples were successfully analyzed using the PowerPlex Y System. Resolution was assessed using the TH01, CSF1PO, TPOX, and Amelogenin loci and demonstrated to be comparable with commercial systems along with the instrument precision. Successful replacement of the Hjerten capillary coating method with a dynamic coating polymer was performed. The accurate and rapid typing of forensic samples demonstrates the successful technology transfer of this device into a practitioner laboratory and its potential for advancing high-throughput forensic typing.


Assuntos
Impressões Digitais de DNA/instrumentação , Eletroforese Capilar , Humanos , Masculino , Reação em Cadeia da Polimerase , Estupro , Espermatozoides , Sequências de Repetição em Tandem
13.
Electrophoresis ; 29(11): 2251-9, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18435498

RESUMO

A fluorescence energy transfer (ET) dye-labeled STR typing system (ET 16-plex) is developed for the markers used in the commercial STR typing kit PowerPlex 16, and its performance assessed using a 96-lane microfabricated capillary array electrophoresis (muCAE) system. The ET 16-plex amplicons displayed 1.6-9-fold higher fluorescence intensities compared to those produced using the single-dye (SD)-labeled multiplex kits. The ET multiplex delivered full STR profiles from 62.5 pg of DNA; half the input required for the SD kits while maintaining a similar heterozygote allele balance. This increased sensitivity should improve typing of poor-quality DNA samples by making minor or imbalanced alleles more readily detectable at the low copy number (LCN) threshold. The ET 16-plex also generated complete profiles with only 28 PCR cycles; this capability should improve LCN typing by reducing the amplification time and drop-in allele incidence. To confirm the practical advantages of ET-labeled primers, six previously problematic casework samples were tested and only the ET 16-plex kit was able to capture additional allele data. The successful development and demonstration of ET primers for higher sensitivity STR typing offers a simple solution to improving current commercial multiplex typing capability. The superior spectral properties and universal compatibility with any primer sequence provided by ET cassettes will make future multiplex construction more facile and straightforward. The pairing of ET cassette technology with the muCAE system illustrates not only an enhanced STR typing platform, but a significant step toward a higher-efficiency forensic laboratory enabled by better chemistry and microfluidics.


Assuntos
Impressões Digitais de DNA/métodos , Genética Forense/métodos , Eletroforese Capilar/métodos , Humanos , Sensibilidade e Especificidade , Espectrometria de Fluorescência
14.
Proc Natl Acad Sci U S A ; 105(2): 476-81, 2008 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-18184818

RESUMO

To realize the immense potential of large-scale genomic sequencing after the completion of the second human genome (Venter's), the costs for the complete sequencing of additional genomes must be dramatically reduced. Among the technologies being developed to reduce sequencing costs, microchip electrophoresis is the only new technology ready to produce the long reads most suitable for the de novo sequencing and assembly of large and complex genomes. Compared with the current paradigm of capillary electrophoresis, microchip systems promise to reduce sequencing costs dramatically by increasing throughput, reducing reagent consumption, and integrating the many steps of the sequencing pipeline onto a single platform. Although capillary-based systems require approximately 70 min to deliver approximately 650 bases of contiguous sequence, we report sequencing up to 600 bases in just 6.5 min by microchip electrophoresis with a unique polymer matrix/adsorbed polymer wall coating combination. This represents a two-thirds reduction in sequencing time over any previously published chip sequencing result, with comparable read length and sequence quality. We hypothesize that these ultrafast long reads on chips can be achieved because the combined polymer system engenders a recently discovered "hybrid" mechanism of DNA electromigration, in which DNA molecules alternate rapidly between repeating through the intact polymer network and disrupting network entanglements to drag polymers through the solution, similar to dsDNA dynamics we observe in single-molecule DNA imaging studies. Most importantly, these results reveal the surprisingly powerful ability of microchip electrophoresis to provide ultrafast Sanger sequencing, which will translate to increased system throughput and reduced costs.


Assuntos
Eletroforese em Microchip/instrumentação , Eletroforese em Microchip/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Análise de Sequência de DNA/instrumentação , Análise de Sequência de DNA/métodos , DNA/análise , DNA de Cadeia Simples/química , Desenho de Equipamento , Genoma Humano , Humanos , Microscopia de Vídeo/métodos , Polímeros/química , Reprodutibilidade dos Testes , Fatores de Tempo
15.
Anal Chem ; 79(20): 7740-7, 2007 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-17874850

RESUMO

We have studied the effects of polymer molar mass and concentration on the electrophoretic migration modalities of individual molecules of DNA in LPA, HEC, and PEO solutions via epifluorescent videomicroscopy. While both transient entanglement coupling (TEC) and reptation have been studied in the past, the transition between them has not. Understanding this transition will allow for polymer network properties to be optimized to enhance the speed and resolution of DNA separations in microfluidic devices. Near the overlap threshold concentration, C*, TEC is the dominant observed mode of DNA migration, and the observation frequency of TEC increases with increasing polymer molar mass. As polymer concentration is increased, observed TEC events reduce to zero while DNA reptation events become the only detected mechanism. Individual DNA molecules undergoing both migration mechanisms were counted in solutions of varying polymer molar masses and concentrations and were plotted against a dimensionless polymer concentration, C/C*. The data for LPA reduce to form universal curves with a sharp increase in DNA reptation at approximately 6.5C*. Analogous transition concentrations for PEO and HEC were observed at 5C* and 3.5C*, respectively, reflecting the different physical properties of these polymers. This transition correlates closely with the polymer network entanglement concentration, Ce, as measured by rheological techniques. The electrophoretic mobility of lambda-DNA in LPA polymer solutions was also measured and shows how a balance can be struck between DNA resolution and separation speed by choosing the desired prevalence of DNA reptation.


Assuntos
DNA/análise , Eletroforese em Gel de Ágar/métodos , Microscopia de Vídeo/métodos , Polímeros/química , Técnicas de Diluição do Indicador , Probabilidade , Soluções , Viscosidade
16.
Anal Chem ; 79(5): 1848-54, 2007 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-17256875

RESUMO

We report a new, bioconjugate approach to performing highly multiplexed single-base extension (SBE) assays, which we demonstrate by genotyping a large panel of point mutants in exons 5-9 of the p53 gene. A series of monodisperse polyamide "drag-tags" was created using both chemical and biological synthesis and used to achieve the high-resolution separation of genotyping reaction products by microchannel electrophoresis without a polymeric sieving matrix. A highly multiplexed SBE reaction was performed in which 16 unique drag-tagged primers simultaneously probe 16 p53 gene loci, with an abbreviated thermal cycling protocol of only 9 min. The drag-tagged SBE products were rapidly separated by free-solution conjugate electrophoresis (FSCE) in both capillaries and microfluidic chips with genotyping accuracy in excess of 96%. The separation requires less than 70 s in a glass microfluidic chip, or about 20 min in a commercial capillary array sequencing instrument. Compared to gel electrophoresis, FSCE offers greater freedom in the design of SBE primers by essentially decoupling the length of the primer and the electrophoretic mobility of the genotyping products. FSCE also presents new possibilities for the facile implementation of SBE on integrated microfluidic electrophoresis devices for rapid, high-throughput genetic mutation detection or SNP scoring.


Assuntos
Análise Mutacional de DNA/métodos , Eletroforese em Microchip , Proteína Supressora de Tumor p53/genética , Primers do DNA/química , Genótipo , Humanos , Nylons/síntese química , Nylons/química , Soluções/química
17.
Lab Chip ; 6(10): 1293-9, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17102842

RESUMO

Functionalized nanoparticles hold great promise in realizing highly sensitive and selective biodetection. We report a single disposable chip which is capable of carrying out a multi-step process that employs nanoparticles--a bio-barcode assay (BCA) for single protein marker detection. To illustrate the capability of the system, we tested for the presence of prostate specific antigen (PSA) in buffer solution and goat serum. Detection was accomplished at PSA concentrations as low as 500 aM. This corresponds to only 300 copies of protein analytes using 1 microL total sample volume. We established that the on-chip BCA for PSA detection offers four orders of magnitude higher sensitivity compared to commercially available ELISA-based PSA tests.


Assuntos
Técnicas Analíticas Microfluídicas , Nanopartículas/química , Antígeno Prostático Específico/sangue , Animais , Ensaio de Imunoadsorção Enzimática , Cabras , Sensibilidade e Especificidade
18.
Electrophoresis ; 27(19): 3823-35, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16972304

RESUMO

With the complete sequencing of the human genome, there is a growing need for rapid, highly sensitive genetic mutation detection methods suitable for clinical implementation. DNA-based diagnostics such as single-strand conformational polymorphism (SSCP) and heteroduplex analysis (HA) are commonly used in research laboratories to screen for mutations, but the slab gel electrophoresis (SGE) format is ill-suited for routine clinical use. The translation of these assays from SGE to microfluidic chips offers significant speed, cost, and sensitivity advantages; however, numerous parameters must be optimized to provide highly sensitive mutation detection. Here we present a methodical study of system parameters including polymer matrix, wall coating, analysis temperature, and electric field strengths on the effectiveness of mutation detection by tandem SSCP/HA for DNA samples from exons 5-9 of the p53 gene. The effects of polymer matrix concentration and average molar mass were studied for linear polyacrylamide (LPA) solutions. We determined that a matrix of 8% w/v 600 kDa LPA provides the most reliable SSCP/HA mutation detection on chips. The inclusion of a small amount of the dynamic wall-coating polymer poly-N-hydroxyethylacrylamide in the matrix substantially improves the resolution of SSCP conformers and extends the coating lifetime. We investigated electrophoresis temperatures between 17 and 35 degrees C and found that the lowest temperature accessible on our chip electrophoresis system gives the best condition for high sensitivity of the tandem SSCP/HA method, especially for the SSCP conformers. Finally, the use of electrical fields between 350 and 450 V/cm provided rapid separations (<10 min) with well-resolved DNA peaks for both SSCP and HA.


Assuntos
Análise Mutacional de DNA/métodos , Eletroforese em Microchip/normas , Genes p53/genética , Análise Heteroduplex/métodos , Polimorfismo Conformacional de Fita Simples , Resinas Acrílicas/química , Análise Mutacional de DNA/normas , Éxons/genética , Humanos , Temperatura
19.
Anal Chem ; 78(13): 4409-15, 2006 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-16808448

RESUMO

We describe a novel class of DNA separation media for microchip electrophoresis, "physically cross-linked" block copolymer networks, which provide rapid (<4.5 min) and remarkably enhanced resolution of DNA in a size range critical for genotyping. Linear poly(acrylamide-co-dihexylacrylamide) (LPA-co-DHA) comprising as little as 0.13 mol % dihexylacrylamide yields substantially improved electrophoretic DNA separations compared to matched molar mass linear polyacrylamide. Single-molecule videomicroscopic images of DNA electrophoresis reveal novel chain dynamics in LPA-co-DHA matrixes, resembling inchworm movement, to which we attribute the increased DNA resolution. Substantial improvements in DNA peak separation are obtained, in particular, in LPA-co-DHA solutions at polymer/copolymer concentrations near the interchain entanglement threshold. Higher polymer concentrations yield enhanced separations only for small DNA molecules (<120 base pairs). Hydrophobically cross-linked networks offer advantages over conventional linear polymers based on enhanced separation performance (or speed) and over chemically cross-linked gels because hydrophobic cross-links can be reversibly broken, allowing facile microchannel loading.


Assuntos
DNA/isolamento & purificação , Eletroforese em Microchip/métodos , Polímeros/química
20.
Proc Natl Acad Sci U S A ; 102(28): 9745-50, 2005 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-15985549

RESUMO

Microfluidic laboratory-on-a-chip (LOC) systems based on a modular architecture are presented. The architecture is conceptualized on two levels: a single-chip level and a multiple-chip module (MCM) system level. At the individual chip level, a multilayer approach segregates components belonging to two fundamental categories: passive fluidic components (channels and reaction chambers) and active electromechanical control structures (sensors and actuators). This distinction is explicitly made to simplify the development process and minimize cost. Components belonging to these two categories are built separately on different physical layers and can communicate fluidically via cross-layer interconnects. The chip that hosts the electromechanical control structures is called the microfluidic breadboard (FBB). A single LOC module is constructed by attaching a chip comprised of a custom arrangement of fluid routing channels and reactors (passive chip) to the FBB. Many different LOC functions can be achieved by using different passive chips on an FBB with a standard resource configuration. Multiple modules can be interconnected to form a larger LOC system (MCM level). We demonstrated the utility of this architecture by developing systems for two separate biochemical applications: one for detection of protein markers of cancer and another for detection of metal ions. In the first case, free prostate-specific antigen was detected at 500 aM concentration by using a nanoparticle-based bio-bar-code protocol on a parallel MCM system. In the second case, we used a DNAzyme-based biosensor to identify the presence of Pb(2+) (lead) at a sensitivity of 500 nM in <1 nl of solution.


Assuntos
Bioquímica/métodos , Microquímica/métodos , Procedimentos Analíticos em Microchip/métodos , Miniaturização/métodos , Nanotecnologia/métodos , Biomarcadores , Dimetilpolisiloxanos , Metais/química , Silicones
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...