Non-contact vibration measurements are relevant for non-invasively characterizing the mechanical behavior of structures. This paper presents a novel methodology for full-field vibrational analysis at high frequencies using the three-dimensional digital image correlation technique combined with the projection of a speckle pattern. The method includes stereo calibration and image processing routines for accurate three-dimensional data acquisition. Quantitative analysis allows the extraction of several deformation parameters, such as the cross-correlation coefficients, shape and intensity, as well as the out-of-plane displacement fields and mode shapes. The potential of the methodology is demonstrated on an Unmanned Aerial Vehicle wing made of composite material, followed by experimental validation with reference accelerometers. The results obtained with the projected three-dimensional digital image correlation show a percentage of error below 5% compared with the measures of accelerometers, achieving, therefore, high sensitivity to detect the dynamic modes in structures made of composite material.