Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 188: 113401, 2020 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-32563056

RESUMO

Cleaning verification (CV) is a critical step in the pharmaceutical manufacturing process to eliminate or reduce unacceptable contamination of a product as a result of insufficiently cleaned equipment surfaces. The main concern is cross contamination with active pharmaceutical ingredients (APIs) from previous runs that may impact patient safety. Current conventional approaches involve rather tedious sample preparation and analytical methods with relative lengthy analysis time. Potent APIs possessing low acceptable daily intake (ADI) values require analytical methods for CV with very low detection limits to confirm that these APIs are below their acceptance limits prior to the next manufacturing process. In this work, a novel end to end CV workflow was developed, which includes the automated sample and calibration solution preparation as well as high throughput analysis by ultra-high-performance liquid chromatography (UHPLC) coupled with single quadrupole mass spectrometry in multiple injection chromatography and selected ion monitoring mode (MIC-MS-SIM). The method was validated using ten model compounds. Acceptable specificity, linearity (R2 > 0.997) and single digit ng/mL LOQ and LOD were achieved for all model compounds. This approach was also successfully applied to the analysis of 22 internal CV samples from an internal program.


Assuntos
Contaminação de Medicamentos , Preparações Farmacêuticas , Cromatografia Líquida de Alta Pressão , Contaminação de Medicamentos/prevenção & controle , Humanos , Espectrometria de Massas , Fluxo de Trabalho
2.
Anal Chem ; 89(16): 8351-8357, 2017 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-28727449

RESUMO

Matrix-assisted laser desorption/ionization (MALDI) coupled with a time-of-flight (TOF) mass-spectrometry (MS) detector is acknowledged to be very useful for analysis of biological molecules. At the same time, hydrogen-deuterium exchange (HDX) is a well-known technique for studying protein higher-order structure. However, coupling MALDI with HDX has been challenging because of undesired back-exchange reactions during analysis. In this report, we survey an approach that utilizes MALDI coupled with an automated sample preparation to compare global conformational changes of proteins under different solution conditions using differential HDX. A nonaqueous matrix was proposed for MALDI sample preparation to minimize undesirable back-exchange. An automated experimental setup based on the use of a liquid-handling robot and automated data acquisition allowed for tracking protein conformational changes as a difference in the number of protons exchanged to deuterons at specified solution conditions. Experimental time points to study the deuteration-labeling kinetics were obtained in a fully automated manner. The use of a nonaqueous matrix solution allowed experimental error to be minimized to within 1% RSD. We applied this newly developed MALDI-HDX workflow to study the effect of several common excipients on insulin folding stability. The observed results were corroborated by literature data and were obtained in a high-throughput and automated manner. The proposed MALDI-HDX approach can also be applied in a high-throughput manner for batch-to-batch higher-order structure comparison, as well as for the optimization of protein chemical modification reactions.


Assuntos
Insulina/química , Ubiquitina/química , Animais , Bovinos , Medição da Troca de Deutério , Humanos , Conformação Proteica , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...