ArXiv ; 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38106457

RESUMO

We present a deep learning framework for volumetric speckle reduction in optical coherence tomography (OCT) based on a conditional generative adversarial network (cGAN) that leverages the volumetric nature of OCT data. In order to utilize the volumetric nature of OCT data, our network takes partial OCT volumes as input, resulting in artifact-free despeckled volumes that exhibit excellent speckle reduction and resolution preservation in all three dimensions. Furthermore, we address the ongoing challenge of generating ground truth data for supervised speckle suppression deep learning frameworks by using volumetric non-local means despeckling-TNode to generate training data. We show that, while TNode processing is computationally demanding, it serves as a convenient, accessible gold-standard source for training data; our cGAN replicates efficient suppression of speckle while preserving tissue structures with dimensions approaching the system resolution of non-local means despeckling while being two orders of magnitude faster than TNode. We demonstrate fast, effective, and high-quality despeckling of the proposed network in different tissue types acquired with three different OCT systems compared to existing deep learning methods. The open-source nature of our work facilitates re-training and deployment in any OCT system with an all-software implementation, working around the challenge of generating high-quality, speckle-free training data.

2.
Artigo em Inglês | MEDLINE | ID: mdl-34398752

RESUMO

Shear-wave elastography (SWE) measures shear-wave speed (SWS), which is related to the underlying shear modulus of soft tissue. SWS in soft tissue changes depending on the amount of external strain that soft tissue is subjected to due to the acoustoelastic (AE) phenomenon. In the literature, variations of SWS as a function of applied uniaxial strain were used for nonlinear characterization, assuming soft tissues to be elastic, although soft tissues are indeed viscoelastic in nature. Hence, nonlinear characterization using SWS alone is insufficient. In this work, we use SWS together with shear-wave attenuation (SWA) during incremental quasi-static compressions in order to derive biomechanical characterization based on the AE theory in terms of well-defined storage and loss moduli. As part of this study, we also quantify the effect of applied strain on measurements of SWS and SWA since such confounding effects need to be taken into account when using SWS and/or SWA, e.g., for staging a disease state, while such effects can also serve as an additional imaging biomarker. Our results from tissue-mimicking phantoms with varying oil percentages and ex vivo porcine liver experiments demonstrate the feasibility of our proposed methods. In both experiments, SWA was observed to decrease with applied strain. For 10% compression in ex vivo livers, shear-wave attenuation decreased, on average, by 28% (93 Np/m), while SWS increased, on average, by 20% (0.26 m/s).


Assuntos
Compressão de Dados , Técnicas de Imagem por Elasticidade , Animais , Fígado/diagnóstico por imagem , Imagens de Fantasmas , Suínos , Viscosidade
3.
Sensors (Basel) ; 19(4)2019 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-30791437

RESUMO

Medical ultrasonic arrays are typically characterized in controlled water baths using measurements by a hydrophone, which can be translated with a positioning stage. Characterization of 3D acoustic fields conventionally requires measurements at each spatial location, which is tedious and time-consuming, and may be prohibitive given limitations of experimental setup (e.g., the bath and stage) and measurement equipment (i.e., the hydrophone). Moreover, with the development of new ultrasound sequences and modalities, multiple measurements are often required to characterize each imaging mode to ensure performance and clinical safety. Acoustic holography allows efficient characterization of source transducer fields based on single plane measurements. In this work, we explore the applicability of a re-radiation method based on the Rayleigh⁻Sommerfeld integral to medical imaging array characterization. We show that source fields can be reconstructed at single crystal level at wavelength resolution, based on far-field measurements. This is herein presented for three practical application scenarios: for identifying faulty transducer elements; for characterizing acoustic safety parameters in focused ultrasound sequences from 2D planar measurements; and for estimating arbitrary focused fields based on calibration from an unfocused sound field and software beamforming. The results experimentally show that the acquired pressure fields closely match those estimated using our technique.

4.
Ultrason Imaging ; 39(3): 189-204, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28091280

RESUMO

It is well-documented in literature that benign breast lesions, such as fibroadenomas, are loosely bonded to their surrounding tissue and tend to slip under a small quasi-static compression, whereas malignant lesions being firmly bonded to their surrounding tissue do not slip. Recent developments in quasi-static ultrasound elastography have shown that an image of the axial-shear strain distribution can provide information about the bonding condition at the lesion-surrounding tissue boundary. Further studies analyzing the axial-shear strain elastograms revealed that nonzero axial-shear strain values appear inside the lesion, referred to as fill-in, only when a lesion is loosely bonded and asymmetrically oriented to the axis of compression. It was argued that the fill-in observed in axial-shear strain elastogram is a surrogate of the actual rigid-body rotation undergone by such a benign lesion due to slip boundary condition. However, it may be useful and perhaps easy to interpret, if the actual rigid-body rotation of the lesion can itself be visualized directly. To estimate this rotation tensor and its spatial distribution map (called a Rotation Elastogram [RE]), it would be necessary to improve the quality of lateral displacement estimates. Recently, it has been shown in the context of Non-Invasive Vascular Elastography (NIVE) that the Synthetic Transmit Aperture (STA) technique can be adapted for elastography to improve the lateral displacement estimates. Therefore, the focus of this work was to investigate the feasibility of employing the STA technique to improve the lateral displacement estimation and assess the resulting improvement in the RE quality. This investigation was done using both simulation and experimental studies. The image quality metric of contrast-to-noise ratio (CNR) was used to evaluate the quality of rotation elastograms. The results demonstrate that the contrast appeared in RE only in the case of loosely bonded inclusion, and the quality of RE improved considerably by employing the STA technique.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Processamento de Imagem Assistida por Computador/métodos , Estudos de Viabilidade , Imagens de Fantasmas , Rotação , Ultrassonografia
5.
Ultrasound Med Biol ; 43(1): 258-272, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27720521

RESUMO

This study was aimed at developing a method for automatically selecting a few representative frames from several hundred axial-shear strain elastogram frames typically obtained during freehand compression elastography of the breast in vivo. This may also alleviate some inter-observer variations that arise at least partly because of differences in selection of representative frames from a cine loop for evaluation and feature extraction. In addition to the correlation coefficient and frame-average axial strain that have been previously used as quality indicators for axial strain elastograms, we incorporated the angle of compression, which has unique effects on axial-shear strain elastogram interpretation. These identified quality factors were computed for every frame in the elastographic cine loop. The algorithm identifies the section having N contiguous frames (N = 10) that possess the highest cumulative quality scores from the cine loop as the one containing representative frames. Data for total of 40 biopsy-proven malignant or benign breast lesions in vivo were part of this study. The performance of the automated algorithm was evaluated by comparing its selection against that by trained radiologists. The observer- identified frame that consisted of a sonogram, axial strain elastogram and axial-shear strain elastogram was compared with the respective images in the frames of the algorithm-identified section using cross-correlation as a similarity measure. It was observed that there was, on average (∼standard deviation), 82.2% (∼2.2%), 83.4% (∼3.8%) and 78.4% (∼3.6%) correlation between corresponding images of the observer-selected and algorithm-selected frames, respectively. The results indicate that the automatic frame selection method described here may provide an objective way to select a representative frame while saving time for the radiologist. Furthermore, the frame quality metric described and used here can be displayed in real time as feedback to guide elastographic data acquisition and for training purposes.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia Mamária/métodos , Algoritmos , Mama/diagnóstico por imagem , Feminino , Humanos , Variações Dependentes do Observador