Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Neurologia (Engl Ed) ; 38(6): 412-418, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35842129

RESUMO

INTRODUCTION: Ischaemic stroke (IS) due to cervical and cerebral artery dissection (CAD) is a rare entity, and few data are available on the use of such reperfusion therapies as intravenous fibrinolysis and mechanical thrombectomy in these patients. We analysed the use of these treatments in patients with IS due to CAD and compared them against patients receiving reperfusion treatment for IS of other aetiologies. METHODS: We conducted an observational, retrospective, multicentre study of patients with IS due to CAD recorded in the National Stroke Registry of the Spanish Society of Neurology during the period 2011-2019. Comparative analyses were performed between: a) patients with CAD treated and not treated with reperfusion therapies and b) patients treated with reperfusion for IS due to CAD and patients treated with reperfusion for IS due to other causes. Epidemiological data, stroke variables, and outcomes at discharge and at 3 months were included in the analysis. RESULTS: The study included 21,037 patients with IS: 223 (1%) had IS due to CAD, of whom 68 (30%) received reperfusion treatment. Reperfusion treatments were used less frequently in cases of vertebral artery dissection and more frequently in patients with carotid artery occlusion. Compared to patients with IS due to other causes, patients with CAD were younger, more frequently underwent mechanical thrombectomy, and less frequently received intravenous fibrinolysis. Rates of haemorrhagic complications, mortality, and independence at 3 months were similar in both groups. CONCLUSIONS: Reperfusion therapy is frequently used in patients with IS due to CAD. The outcomes of these patients demonstrate the efficacy and safety of reperfusion treatments, and are comparable to the outcomes of patients with IS due to other aetiologies.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/etiologia , Isquemia Encefálica/terapia , Isquemia Encefálica/complicações , Estudos Retrospectivos , Resultado do Tratamento , AVC Isquêmico/complicações , Reperfusão/métodos , Artérias Cerebrais
2.
Neurologia (Engl Ed) ; 2020 Dec 21.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33358059

RESUMO

INTRODUCTION: Ischaemic stroke (IS) due to cervical and cerebral artery dissection (CAD) is a rare entity, and few data are available on the use of such reperfusion therapies as intravenous fibrinolysis and mechanical thrombectomy in these patients. We analysed the use of these treatments in patients with IS due to CAD and compared them against patients receiving reperfusion treatment for IS of other aetiologies. METHOD: We conducted an observational, retrospective, multicentre study of patients with IS due to CAD recorded in the National Stroke Registry of the Spanish Society of Neurology during the period 2011-2019. Comparative analyses were performed between: a) patients with CAD treated and not treated with reperfusion therapies and b) patients treated with reperfusion for IS due to CAD and patients treated with reperfusion for IS due to other causes. Epidemiological data, stroke variables, and outcomes at discharge and at 3 months were included in the analysis. RESULTS: The study included 21,037 patients with IS: 223 (1%) had IS due to CAD, of whom 68 (30%) received reperfusion treatment. Reperfusion treatments were used less frequently in cases of vertebral artery dissection and more frequently in patients with carotid artery occlusion. Compared to patients with IS due to other causes, patients with CAD were younger, more frequently underwent mechanical thrombectomy, and less frequently received intravenous fibrinolysis. Rates of haemorrhagic complications, mortality, and independence at 3 months were similar in both groups. CONCLUSIONS: Reperfusion therapy is frequently used in patients with IS due to CAD. The outcomes of these patients demonstrate the efficacy and safety of reperfusion treatments, and are comparable to the outcomes of patients with IS due to other aetiologies.

3.
Cryobiology ; 84: 20-26, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30114383

RESUMO

The warming of cryopreserved samples supported by small volume devices is governed by heat transfer phenomena which are mathematically described by the solution of the transient heat conduction partial differential equations; the convective heat transfer coefficient (h) is an important parameter involved in the boundary condition which is related to the fluid dynamic behavior at the interface device-warming fluid (water, sucrose solution or air). Unfortunately, h values for small volume devices (i.e. Cryotop®) have not been experimentally determined. Moreover, heat transfer coefficients during warming of Cryotop® cannot be obtained through classical dimensionless correlations expressed in terms of Nusselt vs. Reynolds and Prandtl numbers that are available for regular geometries and single materials. It is the purpose of present work to determine the convective heat transfer coefficients (h) by numerically solving the heat transfer equation applying the finite element method. Numerical simulations allowed to predict time-temperature histories and warming rates under different protocols in Cryotop® system which were compared with literature warming rates reported for this device. The h values were calculated considering the heterogeneous structure of the domain (microdrop, plastic-support) and the irregular three-dimensional geometry. The warming conditions analyzed were: a) open system in contact with air and sucrose solution at 23 °C) and b) closed system in contact with air and water at 23 °C. The h values of the Cryotop® open system immersed in sucrose solution (23 °C), that according to literature achieved a survival in the order of 80%, are in the range of 1800-2200 W/m2K. The h values obtained in this work for warming conditions are critical parameters for cryobiologists when studying heat transfer rate in this small volume device.


Assuntos
Criopreservação , Modelos Teóricos , Vitrificação , Criopreservação/instrumentação , Temperatura Alta , Temperatura
4.
Cryo Letters ; 38(2): 119-124, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28534055

RESUMO

BACKGROUND: Dry ice-ethanol bath (-78 degree C) have been widely used in low temperature biological research to attain rapid cooling of samples below freezing temperature. The prediction of cooling rates of biological samples immersed in dry ice-ethanol bath is of practical interest in cryopreservation. The cooling rate can be obtained using mathematical models representing the heat conduction equation in transient state. Additionally, at the solid cryogenic-fluid interface, the knowledge of the surface heat transfer coefficient (h) is necessary for the convective boundary condition in order to correctly establish the mathematical problem. OBJECTIVE: The study was to apply numerical modeling to obtain the surface heat transfer coefficient of a dry ice-ethanol bath. MATERIALS AND METHODS: A numerical finite element solution of heat conduction equation was used to obtain surface heat transfer coefficients from measured temperatures at the center of polytetrafluoroethylene and polymethylmetacrylate cylinders immersed in a dry ice-ethanol cooling bath. The numerical model considered the temperature dependence of thermophysical properties of plastic materials used. RESULTS: A negative linear relationship is observed between cylinder diameter and heat transfer coefficient in the liquid bath, the calculated h values were 308, 135 and 62.5 W/(m2K) for PMMA 1.3, PTFE 2.59 and 3.14 cm in diameter, respectively. CONCLUSION: The calculated heat transfer coefficients were consistent among several replicates; h in dry ice-ethanol showed an inverse relationship with cylinder diameter.


Assuntos
Criopreservação , Gelo-Seco , Etanol/química , Manejo de Espécimes , Propriedades de Superfície , Condutividade Térmica , Temperatura Baixa , Criopreservação/instrumentação , Criopreservação/métodos , Análise de Elementos Finitos , Modelos Teóricos , Projetos de Pesquisa , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos
5.
Cryo Letters ; 36(6): 413-23, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26963888

RESUMO

BACKGROUND: The use of mathematical models describing heat transfer during the freezing process is useful for the improvement of cryopreservation protocols. A widespread practice for cryopreservation of spermatozoa of domestic animal species consists of suspending plastic straws in nitrogen vapor before plunging into liquid nitrogen. Knowledge of surface heat transfer coefficient (h) is mandatory for computational modelling; however, h values for nitrogen vapor are not available. OBJECTIVE: In the present study, surface heat transfer coefficients for plastic French straws immersed in nitrogen vapor over liquid nitrogen was determined; vertical and horizontal positions were considered. MATERIALS AND METHODS: Heat transfer coefficients were determined from the measurement of time-temperature curves and from numerical solution of heat transfer partial differential equation under transient conditions using finite elements. The h values experimentally obtained for horizontal and vertically placed straws were compared to those calculated using correlations based on the Nusselt number for natural convection. RESULTS: For horizontal straws the average obtained value was h=12.5 ± 1.2 W m(2) K and in the case of vertical straws h=16 ± 2.48 W m(2) K. The numerical simulation validated against experimental measurements, combined with accurate h values provides a reliable tool for the prediction of freezing curves of semen-filled straws immersed in nitrogen vapor. CONCLUSION: The present study contributes to the understanding of the cryopreservation techniques for sperm freezing based on engineering concepts, improving the cooling protocols and the manipulation of the straws.


Assuntos
Criopreservação/veterinária , Nitrogênio/química , Preservação do Sêmen/veterinária , Espermatozoides , Condutividade Térmica , Animais , Bovinos , Criopreservação/instrumentação , Criopreservação/métodos , Gases/química , Masculino , Modelos Químicos , Preservação do Sêmen/instrumentação , Preservação do Sêmen/métodos
6.
Cryobiology ; 69(3): 488-95, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25445573

RESUMO

The knowledge of the thermodynamic process during the cooling of reproductive biological systems is important to assess and optimize the cryopreservation procedures. The time-temperature curve of a sample immersed in liquid nitrogen enables the calculation of cooling rates and helps to determine whether it is vitrified or undergoes phase change transition. When dealing with cryogenic liquids, the temperature difference between the solid and the sample is high enough to cause boiling of the liquid, and the sample can undergo different regimes such as film and/or nucleate pool boiling. In the present work, the surface heat transfer coefficients (h) for plastic French straws plunged in liquid nitrogen were determined using the measurement of time-temperature curves. When straws filled with ice were used the cooling curve showed an abrupt slope change which was attributed to the transition of film into nucleate pool boiling regime. The h value that fitted each stage of the cooling process was calculated using a numerical finite element program that solves the heat transfer partial differential equation under transient conditions. In the cooling process corresponding to film boiling regime, the h that best fitted experimental results was h=148.12±5.4 W/m(2) K and for nucleate-boiling h=1355±51 W/m(2) K. These values were further validated by predicting the time-temperature curve for French straws filled with a biological fluid system (bovine semen-extender) which undergoes freezing. Good agreement was obtained between the experimental and predicted temperature profiles, further confirming the accuracy of the h values previously determined for the ice-filled straw. These coefficients were corroborated using literature correlations. The determination of the boiling regimes that govern the cooling process when plunging straws in liquid nitrogen constitutes an important issue when trying to optimize cryopreservation procedures. Furthermore, this information can lead to improvements in the design of cooling devices in the cryobiology field.


Assuntos
Criopreservação/instrumentação , Preservação do Sêmen/instrumentação , Animais , Bovinos , Criopreservação/métodos , Criopreservação/veterinária , Análise de Elementos Finitos , Congelamento , Temperatura Alta , Modelos Biológicos , Modelos Químicos , Nitrogênio/química , Preservação do Sêmen/métodos , Preservação do Sêmen/veterinária
7.
Cryo Letters ; 34(2): 158-65, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23625084

RESUMO

The subject of present work was to predict internal temperature gradients developed during freezing of bovine sperm diluted in extender, packaged in 0.5 ml French plastic straws and suspended in static liquid nitrogen vapor at -100 degree C. For this purpose, a mathematical heat transfer model previously developed to predict freezing times (phase change was considered) of semen/extender packaged in straw was extended to predict internal temperature gradients during the cooling/freezing process. Results showed maximum temperature differences between the centre and the periphery of semen/extender "liquid" column was 1.5 degree C for an external heat transfer coefficient, h = 15 W per (m(2) K), and only 0.5 degree C for h = 5 W per (m(2) K). It is concluded that if a thermocouple wire were inserted in a 0.5 ml plastic straw to monitor the freezing process in nitrogen vapor, its radial position would have little importance since expected internal gradients may be safely neglected. This finding facilitates the interpretation of freezing rates in 0.5 ml plastic straws immersed in nitrogen vapor over liquid nitrogen, a widely used method for cryopreservation of bovine spermatozoa.


Assuntos
Criopreservação/veterinária , Preservação do Sêmen/veterinária , Animais , Bovinos , Simulação por Computador , Criopreservação/instrumentação , Congelamento , Gases/química , Masculino , Modelos Químicos , Nitrogênio/química , Preservação do Sêmen/instrumentação , Espermatozoides/citologia , Temperatura
8.
Cryobiology ; 66(1): 30-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23159803

RESUMO

A widespread practice in cryopreservation is to freeze spermatozoa by suspending the straws in stagnant nitrogen vapor over liquid nitrogen (N(2)V/LN(2)) for variable periods of time before plunging into liquid nitrogen (-196°C) for indefinite storage. A mathematical heat transfer model was developed to predict freezing times (phase change was considered) required for bull semen and extender packaged in 0.5ml plastic straws and suspended in static liquid nitrogen vapor. Thermophysical properties (i.e. thermal conductivity, specific heat, density, initial freezing temperature) of bovine semen and extender as a function of temperature were determined considering the water change of phase. The non-stationary heat transfer partial differential equations with variable properties (nonlinear mathematical problem) were numerically solved considering in series thermal resistances (semen suspension-straw) and the temperature profiles were obtained for both semen suspension and plastic straw. It was observed both the external heat transfer coefficient in stagnant nitrogen vapor and its temperature (controlled by the distance from the surface of liquid nitrogen to the straw) affected freezing times. The accuracy of the model to estimate freezing times of the straws was further confirmed by comparing with experimental literature data. Results of this study will be useful to select "safe" holding times of bull semen in plastic straws placed N(2)V/LN(2) to ensure that complete freezing of the sample has occurred in the nitrogen vapor and avoid cryodamage when plunging in LN(2). Freezing times predicted by the numerical model can be applied to optimize freezing protocols of bull semen in straws.


Assuntos
Criopreservação/veterinária , Preservação do Sêmen/veterinária , Animais , Bovinos , Criopreservação/métodos , Congelamento , Masculino , Modelos Químicos , Sêmen/citologia , Preservação do Sêmen/métodos , Condutividade Térmica
9.
Cryo Letters ; 33(1): 31-40, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22434120

RESUMO

In oocyte vitrification, plunging directly into liquid nitrogen favor film boiling and strong nitrogen vaporization. A survey of literature values of heat transfer coefficients (h) for film boiling of small metal objects with different geometries plunged in liquid nitrogen revealed values between 125 to 1000 W per per square m per K. These h values were used in a numerical simulation of cooling rates of two oocyte vitrification devices (open-pulled straw and Cryotop), plunged in liquid and slush nitrogen conditions. Heat conduction equation with convective boundary condition was considered a linear mathematical problem and was solved using the finite element method applying the variational formulation. COMSOL Multiphysics was used to simulate the cooling process of the systems. Predicted cooling rates for OPS and Cryotop when cooled at -196 degree C (liquid nitrogen) or -207 degree C (average for slush nitrogen) for heat transfer coefficients estimated to be representative of film boiling, indicated lowering the cooling temperature produces only a maximum 10 percent increase in cooling rates; confirming the main benefit of plunging in slush over liquid nitrogen does not arise from their temperature difference. Numerical simulations also demonstrated that a hypothetical four-fold increase in the cooling rate of vitrification devices when plunging in slush nitrogen would be explained by an increase in heat transfer coefficient. This improvement in heat transfer (i.e., high cooling rates) in slush nitrogen is attributed to less or null film boiling when a sample is placed in slush (mixture of liquid and solid nitrogen) because it first melts the solid nitrogen before causing the liquid to boil and form a film.


Assuntos
Simulação por Computador , Criopreservação/métodos , Nitrogênio/química , Oócitos/citologia , Animais , Temperatura Baixa , Feminino , Temperatura Alta , Mamíferos , Transição de Fase , Condutividade Térmica , Vitrificação , Volatilização
10.
Theriogenology ; 77(8): 1717-21, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22225685

RESUMO

Slush nitrogen (SN(2)) is a mixture of solid nitrogen and liquid nitrogen, with an average temperature of -207 °C. To investigate whether plunging a French plastic straw (commonly used for sperm cryopreservation) in SN(2) substantially increases cooling rates with respect to liquid nitrogen (LN(2)), a numerical simulation of the heat conduction equation with convective boundary condition was used to predict cooling rates. Calculations performed using heat transfer coefficients in the range of film boiling confirmed the main benefit of plunging a straw in slush over LN(2) did not arise from their temperature difference (-207 vs. -196 °C), but rather from an increase in the external heat transfer coefficient. Numerical simulations using high heat transfer (h) coefficients (assumed to prevail in SN(2)) suggested that plunging in SN(2) would increase cooling rates of French straw. This increase of cooling rates was attributed to a less or null film boiling responsible for low heat transfer coefficients in liquid nitrogen when the straw is placed in the solid-liquid mixture or slush. In addition, predicted cooling rates of French straws in SN(2) tended to level-off for high h values, suggesting heat transfer was dictated by heat conduction within the liquid filled plastic straw.


Assuntos
Criopreservação/veterinária , Temperatura Alta , Nitrogênio , Espermatozoides/fisiologia , Animais , Criopreservação/instrumentação , Criopreservação/métodos , Masculino , Temperatura
11.
Cryobiology ; 63(1): 32-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21540134

RESUMO

Oocyte cryopreservation is of key importance in the preservation and propagation of germplasm. Interest in oocyte cryopreservation has increased in recent years due to the application of assisted reproductive technologies in farm animals such as in vitro fertilization, nuclear transfer and the need for the establishment of ova/gene banks worldwide. However, the cryopreservation of the female gamete has been met with limited success mainly due to its small surface-area:volume ratio. In the past decade, several vitrification devices such as open pulled straws (OPS), fine and ultra fine pipette tips, nylon loops and polyethylene films have been introduced in order to manipulate minimal volumes and achieve high cooling rates. However, experimental comparison of cooling rates presents difficulties mainly because of the reduced size of these systems. To circumvent this limitation, a numerical simulation of cooling rates of various vitrification systems immersed in liquid nitrogen was conducted solving the non-stationary heat transfer partial differential equation using finite element method. Results indicate the nylon loop (Cryoloop®) is the most efficient heat transfer system analyzed, with a predicted cooling rate of 180,000°C/min for an external heat transfer coefficient h= 1000 W/m(2)K when cooling from 20 to -130°C; in contrast, the open pulled straw method (OPS) showed the lowest performance with a cooling rate of 5521°C/min considering the same value of external heat transfer coefficient. Predicted cooling rates of Miniflex® and Cryotop® (polyethylene film system) were 6164 and 37,500°C/min, respectively, for the same heat transfer coefficient.


Assuntos
Simulação por Computador , Criopreservação/métodos , Oócitos , Vitrificação , Animais , Temperatura Baixa , Criopreservação/instrumentação , Feminino , Temperatura Alta
12.
Cryo Letters ; 31(2): 120-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20687454

RESUMO

Heat transfer plays a key role in cryopreservation of liquid semen in plastic straws. The effect of several parameters on the cooling rate of a liquid-filled polypropylene straw when plunged into liquid nitrogen was investigated using a theoretical model. The geometry of the straw containing the liquid was assimilated as two concentric finite cylinders of different materials: the fluid and the straw; the unsteady-state heat conduction equation for concentric cylinders was numerically solved. Parameters studied include external (convection) heat transfer coefficient (h), the thermal properties of straw manufacturing material and wall thickness. It was concluded that the single most important parameter affecting the cooling rate of a liquid column contained in a straw is the external heat transfer coefficient in LN2. Consequently, in order to attain maximum cooling rates, conditions have to be designed to obtain the highest possible heat transfer coefficient when the plastic straw is plunged in liquid nitrogen.


Assuntos
Criopreservação/instrumentação , Polipropilenos , Preservação do Sêmen/instrumentação , Condutividade Térmica , Animais , Análise de Elementos Finitos , Humanos , Masculino , Modelos Teóricos
13.
Rev. argent. microbiol ; 39(4): 237-242, oct.-dic. 2007. graf, tab
Artigo em Inglês | LILACS | ID: lil-634564

RESUMO

In this work, a simplified method is used to estimate the growth of Staphylococcus aureus in a pasteurized meat product left for several hours at environmental temperatures (diurnal time) in warm climates of different cities in Argentina. Hourly temperature data for a warm January (the hottest month of the year) day, and literature data on the kinetics of S. aureus growth inoculated in a pasteurized meat product were used for calculations. As shown by results, if a cooked meat product is left exposed to environmental temperature at diurnal time, predictions made when using a constant temperature value (i.e. average daily) may not be accurate. Growth estimations in contaminated food left under ambient conditions during diurnal time, should consider the changing environmental temperature for correct results.


En este trabajo se utiliza un método simplificado para predecir el crecimiento de Staphylococcus aureus en un producto cárnico pasteurizado dejado por varias horas a temperatura ambiente diurna en zonas de clima cálido. En la predicción, se utilizaron datos de la temperatura horaria para un día caluroso típico de enero (mes más caliente del año) en varias ciudades de la Argentina y datos de la literatura sobre tiempos de generación y tiempo lag de la bacteria inoculada en un producto cárnico pasteurizado. Los resultados indicaron que cuando el producto se deja a temperatura ambiente diurna durante varias horas, no se debe utilizar para la predicción un valor de temperatura promedio (ej.: temperatura media diaria), sino que hay que tener en cuenta la evolución de este parámetro a lo largo del período considerado.


Assuntos
Animais , Bovinos , Produtos da Carne/microbiologia , Staphylococcus aureus/crescimento & desenvolvimento , Temperatura , Altitude , Argentina , Clima , Culinária , Conservação de Alimentos , Modelos Biológicos , Saúde da População Urbana
14.
Rev Argent Microbiol ; 39(4): 237-42, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18390161

RESUMO

In this work, a simplified method is used to estimate the growth of Staphylococcus aureus in a pasteurized meat product left for several hours at environmental temperatures (diurnal time) in warm climates of different cities in Argentina. Hourly temperature data for a warm January (the hottest month of the year) day, and literature data on the kinetics of S. aureus growth inoculated in a pasteurized meat product were used for calculations. As shown by results, if a cooked meat product is left exposed to environmental temperature at diurnal time, predictions made when using a constant temperature value (i.e. average daily) may not be accurate. Growth estimations in contaminated food left under ambient conditions during diurnal time, should consider the changing environmental temperature for correct results.


Assuntos
Produtos da Carne/microbiologia , Staphylococcus aureus/crescimento & desenvolvimento , Temperatura , Altitude , Animais , Argentina , Bovinos , Clima , Culinária , Conservação de Alimentos , Modelos Biológicos , Saúde da População Urbana
15.
Rev Argent Microbiol ; 32(2): 63-70, 2000.
Artigo em Espanhol | MEDLINE | ID: mdl-10885005

RESUMO

The water activity (aw) and pH of acidified (vinegar) bottled vegetables and meat with vegetables--mostly home-canned--was examined in relation to the potential growth of Clostridium botulinum. Most products (vegetables or meat with vegetables) had water activity above the "per se" inhibitory limit (aw < 0.95) for growth of C. botulinum. Regarding pH, 96% of canned vegetables had a pH lower than 4.6, but 81% of the canned meat with vegetables had a pH above 4.6. This was attributed to the well known buffer effect of food proteins, which makes it difficult to lower food pH during acidification with vinegar. It is concluded that most bottled meat with vegetables constitute a potential hazard since these foods are marketed at room temperature, and botulism toxin may be produced if spores are present.


Assuntos
Clostridium botulinum/crescimento & desenvolvimento , Manipulação de Alimentos , Microbiologia de Alimentos , Carne/microbiologia , Verduras/microbiologia , Concentração de Íons de Hidrogênio , Água
16.
J Food Prot ; 63(7): 965-9, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10914670

RESUMO

The water activity (a(w)) and pH values of commercially available filled fresh pasta and gnocchi packed under modified atmosphere and manufactured in Argentina and Uruguay were examined. The retail survey included 58 samples (several brands) of filled pasta and 11 samples of gnocchi. Fillings consisted of different combinations of cheese (various types), beef, ricotta, ham, chicken, and spinach. The survey revealed that the a(w) values of the 58 samples of filled pasta ranged from 0.916 to 0.973, and their pH values ranged from 5.2 to 7.0. The a(w) of gnocchi was consistently higher and ranged from 0.936 to 0.983, with pH values from 4.8 to 6.4. Some samples of filled pasta and most gnocchi samples were found to have a(w) and pH values that would support growth of spores of Clostridium botulinum, if present, under conditions of temperature abuse (i.e., 30 degrees C).


Assuntos
Clostridium botulinum/isolamento & purificação , Microbiologia de Alimentos , Água/química , Animais , Argentina , Câmaras de Exposição Atmosférica , Clostridium botulinum/crescimento & desenvolvimento , Humanos , Concentração de Íons de Hidrogênio , Esporos Bacterianos/crescimento & desenvolvimento , Esporos Bacterianos/isolamento & purificação , Temperatura , Uruguai
17.
Rev. argent. microbiol ; 32(2): 63-70, abr.-jun. 2000.
Artigo em Espanhol | BINACIS | ID: bin-6718

RESUMO

The water activity (aw) and pH of acidified (vinegar) bottled vegetables and meat with vegetables--mostly home-canned--was examined in relation to the potential growth of Clostridium botulinum. Most products (vegetables or meat with vegetables) had water activity above the "per se" inhibitory limit (aw < 0.95) for growth of C. botulinum. Regarding pH, 96 of canned vegetables had a pH lower than 4.6, but 81 of the canned meat with vegetables had a pH above 4.6. This was attributed to the well known buffer effect of food proteins, which makes it difficult to lower food pH during acidification with vinegar. It is concluded that most bottled meat with vegetables constitute a potential hazard since these foods are marketed at room temperature, and botulism toxin may be produced if spores are present.(AU)


Assuntos
RESEARCH SUPPORT, NON-U.S. GOVT , Clostridium botulinum/crescimento & desenvolvimento , Manipulação de Alimentos , Microbiologia de Alimentos , Carne/microbiologia , Plantas/microbiologia , Concentração de Íons de Hidrogênio , Água
18.
Rev. argent. microbiol ; 32(2): 63-70, abr.-jun. 2000.
Artigo em Espanhol | LILACS | ID: lil-332535

RESUMO

The water activity (aw) and pH of acidified (vinegar) bottled vegetables and meat with vegetables--mostly home-canned--was examined in relation to the potential growth of Clostridium botulinum. Most products (vegetables or meat with vegetables) had water activity above the "per se" inhibitory limit (aw < 0.95) for growth of C. botulinum. Regarding pH, 96 of canned vegetables had a pH lower than 4.6, but 81 of the canned meat with vegetables had a pH above 4.6. This was attributed to the well known buffer effect of food proteins, which makes it difficult to lower food pH during acidification with vinegar. It is concluded that most bottled meat with vegetables constitute a potential hazard since these foods are marketed at room temperature, and botulism toxin may be produced if spores are present.


Assuntos
Clostridium botulinum , Manipulação de Alimentos , Microbiologia de Alimentos , Carne , Plantas , Concentração de Íons de Hidrogênio , Água
19.
Biotechnol Prog ; 16(2): 163-8, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10753440

RESUMO

Differential scanning calorimetry thermograms of various samples of commercial instant active dry yeasts revealed a clear glass transition typical of amorphous carbohydrates and sugars. The resulting glass transition temperatures were found to decrease with increasing moisture content. The observed glass curve was similar to that of pure trehalose, which is known to accumulate in large amounts in baker's yeast. The effect of heat treatment at various temperatures on the fermentative activity (as measured by the metabolic production of CO(2)) of dry yeast was studied. First-order plots were obtained representing the loss of fermentative activity as a function of heating time at the various temperatures assayed. Significant losses of fermentative activity were observed in vitrified yeast samples. The dependence of rate constants with temperature was found to follow Arrhenius behavior. The relationship between the loss of fermentative activity and glass transition was not verified, and the glass transition was not reflected on the temperature dependence of fermentative activity loss.


Assuntos
Temperatura Alta , Leveduras/metabolismo , Biotecnologia/métodos , Varredura Diferencial de Calorimetria , Dióxido de Carbono/metabolismo , Fermentação , Temperatura , Leveduras/química , Leveduras/fisiologia
20.
Rev. argent. microbiol ; 32(2): 63-70, 2000 Apr-Jun.
Artigo em Espanhol | BINACIS | ID: bin-39870

RESUMO

The water activity (aw) and pH of acidified (vinegar) bottled vegetables and meat with vegetables--mostly home-canned--was examined in relation to the potential growth of Clostridium botulinum. Most products (vegetables or meat with vegetables) had water activity above the [quot ]per se[quot ] inhibitory limit (aw < 0.95) for growth of C. botulinum. Regarding pH, 96


of canned vegetables had a pH lower than 4.6, but 81


of the canned meat with vegetables had a pH above 4.6. This was attributed to the well known buffer effect of food proteins, which makes it difficult to lower food pH during acidification with vinegar. It is concluded that most bottled meat with vegetables constitute a potential hazard since these foods are marketed at room temperature, and botulism toxin may be produced if spores are present.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...