Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39013705

RESUMO

BACKGROUND: PROTECT IV is a current enrolling randomized controlled trial evaluating high-risk percutaneous coronary intervention (HR-PCI) with prophylactic Impella versus no Impella to reduce the composite primary endpoint of all-cause death, stroke, myocardial infarction (MI), or cardiovascular hospitalization. In a PROTECT IV-like cohort of patients who underwent HR-PCI without Impella, we aimed to report the rate of major adverse events to determine whether the trial is adequately powered. METHODS AND RESULTS: A total of 700 patients meeting similar inclusion/exclusion criteria of PROTECT IV who underwent HR-PCI without Impella at a single tertiary center from 2008 to 2022 were included in the analysis. The composite rates of all-cause death, MI, target lesion revascularization, and target vessel revascularization at 1, 2, and 3 years were estimated using the Kaplan-Meier method, and the results were used to calculate the sample size under the constant hazard ratio assumption and expected number of events to be observed used in planning PROTECT IV. The primary endpoint occurred in 30.8 % of patients at 2 years. PROTECT IV assumes a hazard ratio of 0.75 using a multivariate Cox regression, which, under a 5 % level and 90 % power, yields 516 events. This implies a 2-year primary outcome rate of 50 % for the non-Impella arm. CONCLUSION: Therefore, PROTECT IV estimates that a sample size of 1252 patients is required for Impella to be declared superior to the non-Impella group. Using our observed 2-year outcome of 30.8 %, we estimate that PROTECT IV requires 1966 patients, demonstrating that PROTECT IV is probably underpowered.

2.
Circ Cardiovasc Interv ; 17(7): e014143, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38853766

RESUMO

Bioprosthetic aortic valve thrombosis is frequently detected after transcatheter and surgical aortic valve replacement due to advances in cardiac computed tomography angiography technology and standardized surveillance protocols in low-surgical-risk transcatheter aortic valve replacement trials. However, evidence is limited concerning whether subclinical leaflet thrombosis leads to clinical adverse events or premature structural valve deterioration. Furthermore, there may be net harm in the form of bleeding from aggressive antithrombotic treatment in patients with subclinical leaflet thrombosis. This review will discuss the incidence, mechanisms, diagnosis, and optimal management of bioprosthetic aortic valve thrombosis after transcatheter aortic valve replacement and bioprosthetic surgical aortic valve replacement.


Assuntos
Valva Aórtica , Bioprótese , Fibrinolíticos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Desenho de Prótese , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/terapia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Fibrinolíticos/efeitos adversos , Fibrinolíticos/administração & dosagem , Incidência , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Anticoagulantes/administração & dosagem , Medição de Risco , Valor Preditivo dos Testes
3.
Am J Cardiol ; 225: 52-60, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38906395

RESUMO

Spontaneous coronary artery dissection (SCAD) is a rare cause of ST-segment elevation myocardial infarction (STEMI), predominantly affecting women. Because primary percutaneous coronary intervention (PPCI) is reserved for a select group of patients, vulnerable and minority patients may experience delays in appropriate management and adverse outcomes. We examined the racial differences in the outcomes for patients with SCAD who underwent PPCI for STEMI. Records of patients aged ≥18 years who underwent PPCI for SCAD-related STEMI between 2016 and 2020 were identified from the National Inpatient Sample database. Clinical, socioeconomic, and hospital characteristics were compared between non-White and White patients. Weighted multivariate analysis assessed the association of race with inpatient mortality, length of stay (LOS), and hospitalization costs. The total weighted estimate of patients with SCAD-STEMI who underwent PPCI was 4,945, constituting 25% non-White patients. Non-White patients were younger (56 vs 60.7 years, p <0.001); had a higher prevalence of diabetes, acute renal failure, and obesity; and were more likely to be uninsured and be in the lowest income group. Inpatient mortality (7.7% vs 8.4%, p = 0.74) and hospitalization costs ($34,213 vs $31,858, p = 0.27) were similar for non-White and White patients, and the adjusted analysis did not show any association between the patients' race and inpatient mortality (odds ratio 0.60, 95% confidence interval [CI] 0.32 to 1.13, p = 0.11) or hospitalization costs (ß [ß coefficient]: 215, 95% CI -4,193 to 4,623, p >0.90). Similarly, there was no association between the patients' race and LOS (incident rate ratio 1.20, 95% CI 1.00 to 1.45, p = 0.054). The weighted multivariate analysis showed that age; clinical co-morbidities such as diabetes, acute renal failure, valvular dysfunction, and obesity; low-income status; and hospitalization in the western region were associated with adverse outcomes. In conclusion, our study does not show any differences in inpatient mortality, LOS, and hospitalization costs between non-White and White patients who underwent PPCI for SCAD-related STEMI.

6.
Catheter Cardiovasc Interv ; 104(1): 34-43, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38713867

RESUMO

Hypertension continues to be a prominent, avoidable factor contributing to major vascular issues on a global scale. Even with lifestyle adjustments and more aggressive medical treatments, maintaining optimal blood pressure levels remains challenging. This challenge has driven the emergence of device-oriented approaches to address hypertension. To assess the safety and efficacy of the Recor Paradise Ultrasound Renal Denervation System, the Circulatory System Devices Panel was convened by the US Food and Drug Administration (FDA). This manuscript provides a condensed overview of the information put forth by the sponsor and the FDA, along with an account of the considerations and conversations that took place during the meeting.


Assuntos
Pressão Sanguínea , Aprovação de Equipamentos , Hipertensão , Artéria Renal , Simpatectomia , United States Food and Drug Administration , Humanos , Estados Unidos , Simpatectomia/efeitos adversos , Simpatectomia/instrumentação , Hipertensão/fisiopatologia , Hipertensão/cirurgia , Artéria Renal/inervação , Artéria Renal/diagnóstico por imagem , Resultado do Tratamento , Rim/irrigação sanguínea , Comitês Consultivos , Desenho de Equipamento , Fatores de Risco
7.
Am Heart J ; 275: 21-34, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38815781

RESUMO

Tricuspid regurgitation (TR) is common and associated with significant mortality and morbidity. Because the effectiveness and safety of medical and surgical treatments are limited, there is a significant unmet need for the treatment of this disease. Therefore, there is a growing market for percutaneous devices that offer safer, less invasive, and more effective treatment options in this patient population. On February 13, 2024, the US Food and Drug Administration (FDA) convened a meeting of the Circulatory System Devices Panel to discuss the safety and effectiveness of the TriClip Transcatheter Valve Repair System (Abbott, Santa Clara, CA, USA). Several important points were discussed, including newly published data from the TRILUMINATE Pivotal study, the use of patient-oriented outcomes for device approval, and a discussion about training requirements and rollout plans when approving a breakthrough device. In this manuscript, we summarize the data presented by the sponsor and FDA and describe the deliberations and discussions during the meeting.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38789341

RESUMO

BACKGROUND: The intricate relationship between mental health disorders, notably anxiety and depression, and chest pain associated with non-obstructive coronary artery disease has become a focus of investigation. METHODS: This study from the Coronary Microvascular Disease Registry (CMDR) evaluated the association of mental health disorders and coronary microvascular dysfunction (CMD) among patients with angina with no obstructive coronary artery disease (ANOCA) who had undergone comprehensive invasive physiological testing for CMD. Clinical data regarding baseline characteristics, comorbidities, and noninvasive cardiac testing were obtained from chart review. The primary outcome of interest was the potential relationship between mental health diagnoses and the presence of CMD. RESULTS: Of patients included in the CMDR, 27 % (41/152) had at least one documented mental health disorder diagnosis (International Classification of Diseases, Tenth Revision codes) and CMD. There was no difference in mental health diagnosis prevalence between CMD-positive and CMD-negative patients (21.1 % vs. 28.9 %, p = 0.34). The most common mental health diagnoses were depression (15.8 %) and anxiety (15.8 %). Furthermore, 46.3 % (19/41) of patients with mental health disorders were prescribed psychiatric medications, with the most common being benzodiazepines (26.8 %). CONCLUSION: Patients with chest pain not due to CMD did not have an increased prevalence of mental health disorders compared with patients with ANOCA due to CMD, challenging the notion of a psychosomatic component in the pathogenesis of ANOCA.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38789342

RESUMO

BACKGROUND: Coronary microvascular dysfunction (CMD) is associated with various inflammatory conditions that worsen endothelial dysfunction. This study aimed to investigate the relationship between CMD and inflammation using common inflammatory markers derived from complete blood count (CBC) analysis. METHODS: Information was gathered from the Coronary Microvascular Disease Registry to examine the neutrophil-to-lymphocyte ratio (NLR), eosinophil-to-monocyte ratio (EMR), and monocyte-to-high-density lipoprotein ratio (MHR) in a cohort of patients with angina who showed non-obstructive coronary arteries and underwent invasive physiological assessments for CMD. RESULTS: Of the 171 patients studied, 126 were CMD-negative and 45 were CMD-positive, constituting two groups of interest. The average age of all patients was 61.7 ± 11.1 years, and 63.7 % were female. No significant differences were observed between the two groups in terms of baseline characteristics, cardiovascular risk factors, or potential anti-inflammatory medications. Furthermore, there were no statistically significant differences in NLR (2.54 ± 3.71 vs. 2.52 ± 2.28, p = 0.97), EMR (0.3 ± 0.21 vs. 0.34 ± 0.29, p = 0.31), or MHR (0.02 ± 0.01 vs. 0.01 ± 0.01, p = 0.54) between CMD-positive and CMD-negative patients. CONCLUSION: Our findings did not show a noteworthy connection between CMD and inflammation, as suggested by various simple CBC-based biomarkers.

13.
Artigo em Inglês | MEDLINE | ID: mdl-38789343

RESUMO

BACKGROUND: Coronary microvascular dysfunction (CMD) has been implicated as a potential mechanism in the pathophysiology of different clinical presentations, including ischemia and no obstructive coronary artery disease (INOCA), myocardial infarction and nonobstructive coronary arteries (MINOCA), stress cardiomyopathy, heart failure, and myocarditis. There are limited data about the role of CMD in cancer therapy-related cardiovascular toxicities. CASE PRESENTATIONS: Four women with a diagnosis of active cancer receiving treatment who developed subsequent MINOCA or INOCA presented for cardiac catheterization. Upon coronary angiography showing no obstructive coronary arteries, coronary function testing was performed to evaluate for CMD. METHODS: Coronary physiology was assessed measuring non-hyperemic (resting full-cycle ratio [RFR]) and hyperemic (fractional flow reserve [FFR]) indices using a physiologic pressure wire. The wire also measured coronary flow reserve (CFR), index of microcirculatory resistance (IMR), and RFR using thermodilution technology. CMD was confirmed if the CFR was <2.5 and the IMR was >25. RESULTS: Among 4 patients with diagnosis of active cancer presenting with chest pain, there was no evidence of obstructive coronary artery disease, leading to separate diagnoses of INOCA, MINOCA, stress cardiomyopathy, and myocarditis. We found CMD in 2 patients (1 with INOCA and 1 with immune checkpoint inhibitor-related myocarditis). CONCLUSIONS: CMD may play a role in cardiovascular toxicities. Further coronary physiology studies are needed to understand the mechanisms of cancer therapy-related cardiovascular toxicity and CMD, as well as optimal preventive and treatment options.

14.
Cardiovasc Revasc Med ; 65: 75-80, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38565427

RESUMO

Transcatheter heart valve (THV) procedures require careful planning and consideration to prevent coronary artery obstruction (CAO), which poses a significant and potentially life-threatening condition, especially in patients undergoing valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR). Despite identifying predictors of CAO and utilization of computed tomography and inputting THV features, a significant uncertainty remains in predicting CAO. The ShortCut™ device (Pi-Cardia, Rehovot, Israel) was purposefully designed to modify the leaflets in patients undergoing TAVR, especially prior to ViV procedures, to overcome the risk for CAO. This review aims to detail the device's objectives, structure, procedural steps, the available clinical data, and future directions for its intended utilization in the structural arena for the prevention of CAO.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Resultado do Tratamento , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/prevenção & controle , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia
15.
Artigo em Inglês | MEDLINE | ID: mdl-38637194

RESUMO

BACKGROUND: Coronary functional testing to formally diagnose coronary microvascular dysfunction (CMD) reduces cardiovascular events and alleviates angina. This study aims to investigate the extensive and complex journey that patients with CMD undergo, from the onset of chest pain to eventual diagnosis. METHODS: Data from the Coronary Microvascular Disease Registry (CMDR) were analyzed, including information on the date of first documentation of chest pain, number of non-invasive and invasive tests the patient underwent, emergency department visits, and hospitalizations. In addition, we estimated the total cost per patient. A total of 61 patients with CMD diagnosis were included in this analysis. RESULTS: Most patients in our cohort were older than 50 years of age. The median time from initial chest pain symptoms to diagnosis was 0.62 (interquartile range [IQR]: 0.06-2.96) years. During this period, patients visited the emergency department a median of 1.0 (IQR: 0.0-2.0) times. Diagnostic tests included 3.0 (IQR: 2.0-6.0) electrocardiograms, 3.0 (IQR: 0.0-6.0) high-sensitivity troponin tests, and 1.0 (IQR: 1.0-2.0) echocardiograms. Prior to diagnosis of CMD, 13 (21.3 %) patients had left heart catheterization without coronary functional testing. Non-invasive testing for ischemia was conducted in 43 (70.5 %) patients. Alternative non-cardiac diagnoses were given to 11 (18.0 %) patients during the diagnostic process, with referrals made to gastroenterology for 16 (26.2 %) and pulmonology for 10 (16.4 %) patients. The cost was almost $2000/patient. CONCLUSION: Timely identification of CMD offers promising opportunities for prompt symptom alleviation, accompanied by reduced visits to the emergency department, cardiovascular testing, invasive medical procedures, and consequently reduced healthcare expenses.

17.
Am Heart J ; 269: 108-117, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38128897

RESUMO

Hypertension remains a leading preventable cause of myocardial infarction, stroke, kidney disease, and cardiovascular death worldwide. Despite lifestyle modifications and intensification of medical therapy, suboptimal blood pressure control is common, spurring the development of device-based therapies for hypertension. The US Food and Drug Administration (FDA) assembled the Circulatory System Devices Panel on August 22-23, 2023, to discuss the safety and effectiveness of renal denervation devices manufactured by Recor Medical and Medtronic. After reviewing the ultrasound-based Recor Paradise renal denervation system the day prior, the panel reconvened to discuss the radiofrequency-based Medtronic Symplicity Spyral Renal Denervation System. In this manuscript, we summarize the data presented by the sponsor and FDA and detail the deliberation and discussion during the meeting.


Assuntos
Sistema Cardiovascular , Hipertensão , Estados Unidos , Humanos , United States Food and Drug Administration , Rim/cirurgia , Pressão Sanguínea , Simpatectomia , Resultado do Tratamento , Anti-Hipertensivos/uso terapêutico
18.
Cardiovasc Revasc Med ; 43: 115-119, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35610138

RESUMO

BACKGROUND: How to implement robotic-assisted PCI safely and when to escalate to more complex cases has not been previously described. We sought to evaluate clinical outcomes in patients undergoing robotic-assisted PCI in the first year of a newly established robotic-assisted PCI program. METHODS: All patients who underwent robotic-assisted PCI in the first 12 months at a single academic center were included in the study. Lesion complexity was characterized as "PRECISE-like", "CORA-PCI-like", or "CORA-PCI excluded" based on established criteria. The primary outcome was clinical success, defined as <30% residual stenosis after stenting with a final TIMI flow grade 2-3 and no procedural complications. Secondary outcomes included robotic success, defined as clinical success with robotic completion, unintentional manual conversion rate, procedure time, and procedural complications. RESULTS: Of the 57 consecutive lesions treated, 12 (22.6%) had a PRECISE-like lesion complexity while 32 (56.1%) had a CORA- PCI-like, and 13 (22.8%) a CORA-PCI excluded lesion complexity. There was no significant difference in clinical success (100.0% vs. 96.7% vs. 100.0%, p = 1.00) among the groups but robotic success was numerically lower as complexity increased (100.0% vs. 80.0% vs. 72.7%, p = 0.15), with an increased frequency of manual conversion. There was no significant difference in procedural complication rates among the groups. The robotic completion rate improved during the study period. CONCLUSION: Robotic-assisted PCI, can be safely implemented in a moderate-sized academic center, with a rapid escalation in patient and lesion complexity.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Fatores de Risco , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
19.
Cardiovasc Revasc Med ; 41: 1-9, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35398010

RESUMO

OBJECTIVES: This study aimed to evaluate whether baseline tricuspid regurgitation (TR) impacted clinical outcomes after mitral valve transcatheter edge-to-edge repair (M-TEER) for severe secondary mitral regurgitation (MR). BACKGROUND: Baseline TR is common among patients undergoing M-TEER for secondary MR, although its impact on clinical outcomes is unclear. METHODS: The Cochrane Library, PubMed/MEDLINE, and Google Scholar were searched according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines from January 1, 2011 through January 31, 2021. Randomized controlled trials and nonrandomized prospective studies that evaluated baseline TR by echocardiography before M-TEER for MR were included. The primary outcome was a composite of mortality and heart failure hospitalization (HFH) at 1-year. RESULTS: A total of 5 studies (n = 1395 patients) were included in the primary analysis. Concurrent moderate/severe TR was associated with a worse 1 year composite of all-cause mortality and HFH (OR: 2.13; 95% CI: 1.12-4.05; p = 0.02) after M-TEER for severe MR. In studies that reported TR grade pre- and post-M-TEER for severe MR, 32% of patients with moderate-to-severe baseline TR had a reduction in TR severity after the intervention. CONCLUSIONS: Baseline moderate-to-severe TR was associated with increased 1-year mortality and heart failure hospitalizations among patients undergoing M-TEER. Further randomized studies are needed to assess the interaction of TR among patients undergoing M-TEER.


Assuntos
Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Insuficiência Cardíaca/terapia , Humanos , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento , Insuficiência da Valva Tricúspide/cirurgia
20.
Curr Oncol Rep ; 24(4): 475-491, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35192115

RESUMO

PURPOSE OF REVIEW: Tyrosine kinase inhibitors (TKI) and monoclonal antibodies (mAbs) that target the epidermal growth factor receptor (EGFR) have changed the therapeutic landscape across a range of solid malignancies. However, there is little data regarding the cardiovascular (CV) impact of these agents. The purpose of this review is to discuss reported CV effects, pathophysiology, pre-treatment screening, diagnostic workup, and treatment recommendations in this patient population. RECENT FINDINGS: It is apparent that CV events are not class dependent, and while infrequently reported in clinical trials, unique CV toxicity may occur with EGFR inhibitors, including structural, electrical, and vascular events. There remains an unmet need to fully elucidate the spectrum of CV events associated with EGFR inhibitors. Early CV screening, close clinical monitoring, coupled with a multidisciplinary approach between medical and cardio-oncology is needed to minimize the potentially detrimental impact of cardiotoxicity in this patient population.


Assuntos
Antineoplásicos , Doenças Cardiovasculares , Neoplasias Pulmonares , Neoplasias , Anticorpos Monoclonais/efeitos adversos , Antineoplásicos/efeitos adversos , Doenças Cardiovasculares/induzido quimicamente , Doenças Cardiovasculares/tratamento farmacológico , Receptores ErbB , Fatores de Risco de Doenças Cardíacas , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Mutação , Neoplasias/tratamento farmacológico , Inibidores de Proteínas Quinases/efeitos adversos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...