Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Minerva Anestesiol ; 87(10): 1109-1116, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34676743

RESUMO

BACKGROUND: I-gelTM is a second-generation supraglottic airway device with a non-inflatable cuff. In this prospective randomized investigation, we evaluated the effects of two-handed jaw thrust technique on i-gel insertion in anesthetized non-paralyzed patients. METHODS: Seventy-four adult patients were allocated to two groups (N.=37 each). In the jaw thrust group, two-handed jaw thrust technique was applied to facilitate i-gel insertion. In the control group, conventional i-gel insertion was performed. The success rate at the first attempt, air leakage pressure, insertion time, and postoperative sore throat incidence were recorded. RESULTS: The success rate at the first attempt was higher in the jaw thrust group (37 [100%] vs. 31 [84%], difference of 16%, 95% confidence interval for the difference: 1 to 33%, P=0.03). The median air leakage pressure was higher in the jaw thrust group than in the control group (20 [interquartile range 13] vs. 17 [interquartile range 3] cmH2O, difference: 6, 95% confidence interval of the difference: 3 to 8, P<0.01). The mean insertion time was shorter in the jaw thrust group (27±14 vs. 41±29 seconds, difference: 14 seconds, 95% confidence interval of the difference: 3 to 24, P=0.01). The incidence of postoperative sore throat at the postoperative one hour was lower in the jaw thrust group (seven [20%] vs. 15 [41%], difference 22%, 95% confidence interval for the difference: -1 to 42%, P=0.04). CONCLUSIONS: The two-handed jaw thrust technique facilitated i-gel insertion compared to the conventional technique in anesthetized non-paralyzed patients.


Assuntos
Máscaras Laríngeas , Faringite , Adulto , Anestesia Geral , Humanos , Intubação Intratraqueal , Faringite/epidemiologia , Faringite/etiologia , Estudos Prospectivos
2.
Eur J Anaesthesiol ; 37(2): 105-112, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31860598

RESUMO

BACKGROUND: Tracheal intubation using a double-lumen endobronchial tube (DLT) causes postoperative sore throat. OBJECTIVE: To determine the effect of two-handed jaw thrust on postoperative sore throat in patients requiring insertion of a DLT. DESIGN: A randomised study. SETTING: A tertiary teaching hospital from December 2017 to May 2018. PATIENTS: One-hundred and six patients undergoing one-lung anaesthesia. INTERVENTIONS: Patients were allocated to one of two groups (n=53 each). In the jaw thrust group, the two-handed jaw thrust manoeuvre was applied at intubation and advancement of the DLT. In the control group, conventional intubation with a sham jaw thrust was performed. MAIN OUTCOME MEASURES: Incidence of sore throat at 1, 6 and 24 h postoperatively. RESULTS: The incidence of sore throat at 6 h postoperatively was higher in the control group than in the jaw thrust group [31 (59%) vs. 14 (26%), risk ratio (95% confidence interval) 0.45 (0.27 to 0.75), P < 0.01]. The overall incidence of sore throat was higher in the control group than in the jaw thrust group [35 (66%) vs. 18 (34%), risk ratio (95% confidence interval) 0.51 (0.34 to 0.78), P < 0.01]. CONCLUSION: The jaw thrust manoeuvre can reduce the incidence of sore throat in patients undergoing DLT insertion for one-lung ventilation. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03331809.


Assuntos
Faringite , Complicações Pós-Operatórias , Humanos , Incidência , Intubação Intratraqueal/efeitos adversos , Faringite/diagnóstico , Faringite/epidemiologia , Faringite/etiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Período Pós-Operatório
4.
Reg Anesth Pain Med ; 32(2): 102-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17350519

RESUMO

BACKGROUND AND OBJECTIVES: Epidural cannulation is technically difficult in children who have small anatomic structures. Ultrasound information regarding the distance of skin-to-ligament flavum may be useful, leading to an increase in success rate without dural puncture. This study was performed to assess whether ultrasound-measured, skin-to-ligament flavum distance would reflect the needle depth during epidural puncture in infants and children. METHODS: The study compromised 180 children, aged 2 to 84 months, undergoing urologic surgery. After induction of anesthesia, ultrasound images of the longitudinal median and transverse views were acquired from L4-L5 in lateral decubitus position. Measured distance of skin-to-ligament flavum in each view was compared with the perpendicular skin-to-epidural depth, which was obtained from needle depth and angle by use of a trigonometric ratio equation. Additionally, we evaluated the ultrasound visibility of the ligament flavum and dura mater, number of puncture attempts, and complications. RESULTS: The correlation coefficient between measured distance and perpendicular epidural depth was slightly higher in longitudinal median view (R2 = 0.848) than in transverse view (R2 = 0.788). The visibility of ligament flavum and dura mater was "good" in 91 and 170 of 180 patients, respectively, and "sufficient" in the remaining subjects. The epidural space was located on first puncture attempt in 179 of 180 cases (99.4%). No incidents of dural puncture or bloody tap occurred. CONCLUSIONS: Ultrasound, particularly in the longitudinal median view, provides accurate information on the distance of skin-to-ligament flavum in infants and children. With reference to the measured distance, epidural puncture can be performed with minimal risk of dural puncture (upper limit of 95% CI = 1.67%).


Assuntos
Anestesia Epidural/instrumentação , Ligamento Amarelo/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Pré-Escolar , Espaço Epidural/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Análise de Regressão , Punção Espinal/instrumentação , Punção Espinal/métodos , Ultrassonografia
5.
J Med Virol ; 79(2): 118-26, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17177309

RESUMO

Lentiviruses are unique in their ability to infect both dividing and non-dividing cells. This makes the vectors derived from them particularly useful for gene transfer into non-dividing cells, including stem cells. Lentiviral vectors are becoming the vectors of choice for si/shRNA delivery. The utility of the lentiviral vectors will be enhanced if additional elements of safety are built into their design. One safety concern is the generation of replication competent virus by recombination. We reasoned that HIV-1 and HIV-2 hybrid or chimeric lentiviral vectors will have added safety insurance in this regard. This is based on the premise that HIV-1 and HIV-2 are dissimilar enough in sequence to curtail recombination, yet similar enough to complement functionally. For hybrid vectors, we found that both HIV-1 and HIV-2 transfer vector RNAs could be packaged to equivalent titer by the HIV-1 packaging machinery. However, HIV-2 packaging machinery was unable to package HIV-1 transfer vector as well as it did HIV-2 transfer vector. This non-reciprocacity suggested that the requirement for HIV-2 vectors was more stringent and that for HIV-1 vectors more promiscuous. When the HIV-1 transfer vector was packaged with the chimeric packaging construct where the leader-gag region of HIV-2 was replaced with that of HIV-1 packaging construct, the titer of the vector went up. This suggests that at least some of the determinants of specificity for vector assembly reside in the leader-gag region. Incorporation of central polypurine tract (cPPT) and woodchuck post-transcriptional enhance element (WPRE) into the HIV-2 vectors had only modest effect on vector titer. Thus, chimeric lentiviral vectors with added safety features can be designed without compromising transduction efficiency.


Assuntos
Vetores Genéticos/normas , HIV-1/genética , HIV-2/genética , Recombinação Genética , Segurança , Linhagem Celular , Elementos Facilitadores Genéticos , Produtos do Gene gag/genética , Produtos do Gene gag/metabolismo , HIV-1/metabolismo , HIV-1/fisiologia , HIV-2/metabolismo , HIV-2/fisiologia , Humanos , Lentivirus/genética , Lentivirus/metabolismo , Mutagênese Insercional , Montagem de Vírus , Replicação Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...