1.
Rhinology ; 54(4): 329-335, 2016 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-27395040

RESUMO

BACKGROUND: We aimed to compare the prevalence and risk factors of chronic rhinosinusitis (CRS) using two different diagnostic criteria with the same statistical data from the Korean National Health and Nutrition Examination Survey in 2009. METHODS: Symptom-based CRS was defined as CRS diagnosed by questionnaires related to nasal symptoms. Endoscopy-based CRS was defined based on endoscopic findings and nasal symptoms of symptom-based CRS. RESULTS: The overall prevalence of CRS based on the different diagnostic criteria was as follows: symptom-based CRS was 10.78% (797 of 7,394) and endoscopy-based CRS was 1.20% (88 of 7,343). Comparing symptom-based CRS to endoscopy-based CRS showed slight agreement (kappa = 0.183 (0.150-0.216, 95% confidence interval)). Allergic rhinitis was identified as a common risk factor for CRS based on the two diagnostic criteria. CONCLUSIONS: The prevalence and risk factors of CRS were quite different from each other according to the different criteria, even in the same population. Therefore, it would be important to consider what specific diagnostic criteria have been adopted in the studies comparing the prevalence of CRS.


Assuntos
Asma/epidemiologia , Diabetes Mellitus/epidemiologia , Hipertensão/epidemiologia , Rinite/epidemiologia , Sinusite/epidemiologia , Fumar/epidemiologia , Estresse Psicológico/epidemiologia , Adolescente , Adulto , Criança , Doença Crônica , Endoscopia , Dor Facial , Feminino , Humanos , Vacinas contra Influenza/uso terapêutico , Masculino , Pessoa de Meia-Idade , Obstrução Nasal , Septo Nasal/anormalidades , Transtornos do Olfato , Prevalência , República da Coreia/epidemiologia , Rinite/diagnóstico , Rinite Alérgica/epidemiologia , Fatores de Risco , Sinusite/diagnóstico , Inquéritos e Questionários , Adulto Jovem
2.
Br J Radiol ; 88(1050): 20140468, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25873479

RESUMO

OBJECTIVE: To evaluate whether switching bipolar radiofrequency ablation (SB-RFA) using three internally cooled wet (ICW) electrodes can induce coagulations >5 cm in porcine livers with better efficiency than consecutive monopolar (CM) or switching monopolar (SM) modes. METHODS: A total of 60 coagulations were made in 15 in vivo porcine livers using three 17-gauge ICW electrodes and a multichannel radiofrequency (RF) generator. RF energy (approximately 200 W) was applied in CM mode (Group A, n = 20) for 24 min, SM mode for 12 min (Group B, n = 20) or switching bipolar (SB) mode for 12 min (Group C, n = 20) in in vivo porcine livers. Thereafter, the delivered RFA energy, as well as the shape and dimension of coagulations were compared among the groups. RESULTS: Spherical- or oval-shaped ablations were created in 30% (6/20), 85% (17/20) and 90% (18/20) of coagulations in the CM, SM and SB groups, respectively (p = 0.003). SB-RFA created ablations >5 cm in minimum diameter (Dmin) in 65% (13/20) of porcine livers, whereas SM- or CM-RFA created ablations >5 cm in only 25% (5/20) and 20% (4/20) of porcine livers, respectively (p = 0.03). The mean Dmin of coagulations was significantly larger in Group C than in Groups A and B (5.1 ± 0.9, 3.9 ± 1.2 and 4.4 ± 1.0 cm, respectively, p = 0.002) at a lower delivered RF energy level (76.8 ± 14.3, 120.9 ± 24.5 and 114.2 ± 18.3 kJ, respectively, p < 0.001). CONCLUSION: SB-RFA using three ICW electrodes can create coagulations >5 cm in diameter with better efficiency than do SM- or CM-RFA. ADVANCES IN KNOWLEDGE: SB-RFA can create large, regular ablation zones with better time-energy efficiency than do CM- or SM-RFA.


Assuntos
Ablação por Cateter/instrumentação , Eletrodos , Fígado/cirurgia , Animais , Desenho de Equipamento , Modelos Animais , Ondas de Rádio , Suínos
3.
Ultraschall Med ; 34(1): 11-29, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23129518

RESUMO

Initially, a set of guidelines for the use of ultrasound contrast agents was published in 2004 dealing only with liver applications. A second edition of the guidelines in 2008 reflected changes in the available contrast agents and updated the guidelines for the liver, as well as implementing some non-liver applications. Time has moved on, and the need for international guidelines on the use of CEUS in the liver has become apparent. The present document describes the third iteration of recommendations for the hepatic use of contrast enhanced ultrasound (CEUS) using contrast specific imaging techniques. This joint WFUMB-EFSUMB initiative has implicated experts from major leading ultrasound societies worldwide. These liver CEUS guidelines are simultaneously published in the official journals of both organizing federations (i.e., Ultrasound in Medicine and Biology for WFUMB and Ultraschall in der Medizin/European Journal of Ultrasound for EFSUMB). These guidelines and recommendations provide general advice on the use of all currently clinically available ultrasound contrast agents (UCA). They are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis and improve the management of patients worldwide.


Assuntos
Carcinoma Hepatocelular/ultraestrutura , Meios de Contraste/administração & dosagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Hepatopatias/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Anafilaxia/induzido quimicamente , Anafilaxia/mortalidade , Biópsia por Agulha/métodos , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Transformação Celular Neoplásica/patologia , Contraindicações , Meios de Contraste/efeitos adversos , Diagnóstico Diferencial , Hipersensibilidade a Drogas/etiologia , Hipersensibilidade a Drogas/mortalidade , Interações Medicamentosas , Compostos Férricos/efeitos adversos , Fluorocarbonos/efeitos adversos , Humanos , Ferro/efeitos adversos , Fígado/patologia , Fígado/cirurgia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Hepatopatias/patologia , Hepatopatias/cirurgia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Transplante de Fígado/patologia , Óxidos/efeitos adversos , Fosfolipídeos/efeitos adversos , Fatores de Risco , Hexafluoreto de Enxofre/efeitos adversos , Ultrassonografia Doppler/métodos , Ultrassonografia de Intervenção/métodos
4.
Br J Radiol ; 85(1018): e891-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22972978

RESUMO

OBJECTIVE: To investigate the potential diagnostic value of dual-energy CT (DECT) with virtual non-enhanced (VNE) and iodine-only images, and to determine the optimal mixed ratio of blended images for evaluation of pancreatic diseases. METHODS: Multiphasic DECT was performed in 44 patients with focal pancreatic disease. DECT was used during the pancreatic and hepatic venous phases, and a peak kilovoltage of 120 kVp was used for both non-contrast phases. For qualitative analysis of the CT images, two radiologists assessed three image sets (VNE, iodine-only and blended images) in order to determine the acceptability of VNE in replacing true non-enhanced (TNE) images, the added value of iodine-only images and the preferred blending ratio. For quantitative analyses, the CT numbers and image noise of the pancreatic parenchyma, lesions, aorta and psoas muscle were measured. The contrast-to-noise ratio of the lesion was calculated on the pancreatic phase images. The effective radiation dose for DECT and TNE images was calculated. Statistical comparisons were made using the Friedman test, the Wilcoxon test, the paired t-test and repeated measures of analysis of variation with Bonferroni correction for multiple comparisons. RESULTS: The level of acceptance of the VNE images in replacing TNE images was 90.9%. Regarding the iodine-only images, 50% of the cases were found to have an added value. The linear-blended images with a weighting factor of 0.5 were preferred. CONCLUSIONS: DECT was able to provide high-quality VNE images that could replace TNE images and iodine-only images showing an added value. Blended images with a weighting factor of 0.5 were preferred by the reviewers.


Assuntos
Tomografia Computadorizada Multidetectores/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doses de Radiação , Estudos Retrospectivos
5.
Br J Radiol ; 85(1017): e573-83, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22919011

RESUMO

OBJECTIVE: The objective of this study was to determine the incidence of typical and atypical enhancement patterns of hepatocellular carcinomas (HCCs) on multiphasic multidetector row CT (MDCT) and to correlate the enhancement patterns and morphological image findings of HCC with the degree of tumour differentiation. METHODS: MDCT images of 217 patients with 243 surgically proven HCCs were evaluated through consensus reading by two radiologists. Our MDCT protocol was composed of precontrast, arterial, portal and delayed phases. The reviewers analysed the CT images for degree of attenuation; relative timing of washout; presence of dysmorphic intratumoral vessels, aneurysms and necrosis; tumour size; tumour margin; presence of pseudocapsule; intratumoral heterogeneity; and determined enhancement pattern. The imaging features were correlated with tumour differentiation using Fisher's exact test or the χ(2) test. RESULTS: Among 243 HCCs, 137 (56.4%) showed the typical enhancement pattern of HCC, which is arterial enhancement and washout on portal or equilibrium phase images. In the arterial phase, 190 of 243 (78.2%) HCCs showed hypervascularity, with approximately three quarters of poorly differentiated (PD) (34 of 45, 75.6%) and moderately differentiated (MD) HCCs (92 of 123, 74.8%) showing washout during the portal or delayed phases, vs only 50% of well-differentiated (WD) HCCs (11 of 22; p<0.048). The presence of intratumoral vessels and aneurysms, tumour necrosis, attenuation of precontrast, the relative timing of washout, intratumoral attenuation heterogeneity, tumour margin and tumour size were correlated with the pathological differentiation of HCCs (p<0.05). CONCLUSION: A typical enhancement of HCCs on MDCT was not unusual (43.6%) and WD and PD HCCs account for most of the atypical enhancement patterns. Early washout favoured MD and PD HCCs rather than WD HCCs, whereas in our study the presence of intratumoral aneurysm was a highly specific finding for PD HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/epidemiologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/epidemiologia , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , República da Coreia/epidemiologia , Fatores de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
6.
Br J Radiol ; 85(1017): e609-15, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22422385

RESUMO

OBJECTIVES: The objective of this study was to determine the in vivo efficacy of radiofrequency ablation (RFA) in porcine liver using Octopus® electrodes for creating a large coagulation compared with RFA using clustered electrodes. METHODS: A total of 39 coagulations were created using a 200-W generator and clustered electrodes or Octopus electrodes during laparotomy in 19 pigs. Radiofrequency was applied to the livers using four protocols: (1) Group A-1, monopolar mode using a clustered electrode (n=11); (2) Group A-2, monopolar mode using an Octopus electrode (n=11); (3) Group B-1, consecutive monopolar mode using three, clustered electrodes (n=8); and (4) Group B-2, switching monopolar mode using two Octopus electrodes (n=9). The energy efficiency, shape, diameters (D) and volume (V) of the coagulation volume were compared in each of the two groups. RESULTS: The mean maximum D and V of the coagulations in Group A-2 (4.7 cm and 33.1 cm(3), respectively) were significantly larger than those in Group A-1 (4.1 cm and 20.3 cm(3), respectively) (p<0.05). Furthermore, the mean minimum D, maximum D and V of the coagulations in Group B-2 were significantly larger than those in Group B-1, i.e. 5.3 vs 4.0 cm, 6.6 vs 4.9 cm and 66.9 vs 30.2 cm(3), respectively (p<0.05). The energy efficiencies were also significantly higher in Groups A-2 and B-2 than in Groups A-1 and B-1 (p<0.05). CONCLUSION: The Octopus electrodes were more efficient for creating a large ablation zone than clustered electrodes, and the efficacy of RFA with Octopus electrodes can be amplified in the switching monopolar mode.


Assuntos
Ablação por Cateter/instrumentação , Eletrodos , Hepatectomia/instrumentação , Fígado/patologia , Fígado/cirurgia , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Masculino , Suínos
8.
Abdom Imaging ; 36(3): 230-1, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21267564

RESUMO

These review articles will enhance the knowledge of radiologists about current imaging modalities and various contrast agents for the detection and characterization hepatocellular nodules including hepatocellular carcinoma (HCC) in liver cirrhosis, and new concepts of imaging findings, and enable to understand these nodules more completely and thus accurately diagnose HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Cirrose Hepática/complicações , Neoplasias Hepáticas/diagnóstico , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/complicações , Meios de Contraste , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/complicações , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Ultrassonografia
9.
Br J Radiol ; 79(943): 562-71, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16823060

RESUMO

The purpose of this study was to compare the amounts of in vivo coagulation obtained by radiofrequency (RF) ablation in porcine lung, using three types of electrodes. 15 in vivo ablation procedures were performed in the lungs of five pigs using three kinds of currently available RF devices under CT guidance. After placing an electrode in the lung, three ablation zones were created at each of three different regimens: Group A: RF ablation with an internally cooled electrode; Group B: RF ablation with a perfusion electrode, with instillation of 0.9% NaCl solution at a rate of 1.5 ml min(-1); Group C: RF ablation with a multitined expandable electrode. According to the manufacturer's recommendations, RF application times were 12 min in group A and 20 min in group B. In group C, RF energy was delivered for 7 min after a mean temperature of 110 degrees C was reached at 5 cm deployment. 36 min after the procedures, contrast-enhanced CT scans were obtained to evaluate the volume of zone of coagulation, and lungs were harvested for gross measurements. After macroscopic and histopathological analyses of 5 mm-thick lung sections, diameters, volumes and variation coefficients of regions of central coagulation were assessed. During RF ablation, the perfusion electrode allowed a larger energy delivery than the internally cooled or the multitined expandable electrodes, i.e. 33.6+/-4.7 kJ in group A, 40.0+/-8.2 kJ in group B and 23.5+/-6.1 kJ in group C (p<0.05). On gross observation, the cut surface of the gross specimen containing RF-induced coagulation showed that the ablated tissue appeared to be a central, firm, dark-brown area surrounded by an irregular outer margin (approximately 3-10 mm thick) of bright red tissue. In vivo studies showed that RF ablation using the perfusion electrode achieved larger coagulation volume than RF ablation using the other electrodes (p<0.05): 7.2+/-4.1 cm3 in group A; 16.9+/-5.5 cm3 in group B; 7.5+/-3.3 cm3 in group C. The corresponding variation coefficients were 0.55, 0.31, and 0.45, respectively. Our study shows that RF ablation using a perfusion electrode achieves a larger coagulation volume with an irregular margin than RF ablation using internally cooled or multitined expandable electrodes in the porcine lung.


Assuntos
Ablação por Cateter/métodos , Pulmão/cirurgia , Animais , Ablação por Cateter/instrumentação , Eletrodos , Desenho de Equipamento , Pulmão/anatomia & histologia , Neoplasias Pulmonares/cirurgia , Distribuição Aleatória , Suínos , Tomografia Computadorizada por Raios X
10.
Clin Radiol ; 61(6): 483-94, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16713419

RESUMO

AIM: To compare wet and dry preparation methods for computed tomography colonography (CTC) in terms of preparation quality, interpretation time, and diagnostic performance for polyp detection in a population with a high residue diet. MATERIALS AND METHODS: Eighty-six patients were divided into two groups. Group 1 (n=24) received a wet preparation of 4l polyethylene glycol (PEG) solution, and group 2 (n=62) received a dry preparation of phosphor-soda. Abnormal findings, including polyps, and the time required to interpret the CTC images in both groups were documented by a radiologist. CTC findings were compared to those of colonoscopy as a reference standard. Two radiologists evaluated the quality of CTC with regard to residual fluid, faeces, and colonic distension using a four-point scale in consensus. Statistical differences for residual fluid, faeces, distensibility on CTC, and interpretation time between the two groups were analysed. The diagnostic performance of CTC in both groups was also compared. RESULTS: One-hundred and ninety polyps in 70 patients were identified using colonoscopy. Regarding the quality of images produced the wet preparation was significantly better than the dry preparation (p<0.05). The average interpretation time was significantly shorter for the wet group (11.7 min) than the dry group (16.4 min) (p<0.05). For per-patient analysis, the positive predictive value (PPV) was significantly better for the wet (100%) than the dry group (79.6%; p=0.025). Sensitivities and PPV for >or=10 mm polyps were comparable between two groups (p>0.05). CONCLUSION: In a population with a high-residue diet, CTC with wet preparation can be interpreted in a time-efficient manner and is comparable with CTC with dry preparation.


Assuntos
Polipose Adenomatosa do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Dieta , Polipose Adenomatosa do Colo/etnologia , Adulto , Idoso , Povo Asiático , Catárticos , Colonografia Tomográfica Computadorizada/normas , Enema/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polietilenoglicóis/uso terapêutico , Sensibilidade e Especificidade , Solventes/uso terapêutico
11.
Acta Radiol ; 46(5): 443-51, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16224916

RESUMO

PURPOSE: To determine optimal parameters for bipolar radiofrequency ablation (RFA) using perfusion-cooled electrodes to create a large ablation volume in ex vivo bovine liver. MATERIAL AND METHODS: Three sets of RF experiments were performed using a 200-Watt generator and two 15-gauge perfusion-cooled or internally cooled electrodes in ex vivo bovine livers. In the first set of experiments, to find the ideal inter-electrode distance for creating large coagulation necrosis, 30 ablation lesions were created by bipolar RFAs at inter-electrode spacings of 3 cm, 4 cm, and 5 cm. In the second set of experiments, to explore the ideal duration of RF application, bipolar RFAs were performed for 10 min and 20 min. In the first and second experiments, 10 lesions were made for each condition with infusion of 6% hypertonic saline (HS) at 2 ml/min. In the third set of experiments, 10 ablation lesions were created by bipolar RFAs using internally cooled electrodes without HS infusion. The mean volume of those ablation lesions was then compared to that of the lesions created by bipolar RFA using perfusion-cooled electrodes in the second experiments. Tissue impedance, dimension, and shape of the ablated areas were compared in each condition. RESULTS: In the first set of experiments, bipolar RFA created a homogeneous oval or spherical-shaped ablation area between the electrodes at 3-5 cm spacing, but showed a more spherical-shaped lesion at 3 cm inter-electrode spacing than at 4 cm and 5 cm spacing. In the second set of experiments, RF energy delivered for 20 min created a larger dimension of coagulation necrosis than energy delivered for 10 min: 107.6 +/- 34 cm3 versus 59.5 +/- 27 cm3 (P<0.05). In addition, the mean volume of ablation regions obtained with bipolar RFA using the internally cooled electrode was 47.5+/- 17 cm3, which was significantly less than that with bipolar RFA using perfusion-cooled electrodes (P <0.05). CONCLUSION: Bipolar RFA using perfusion-cooled electrodes achieves homogeneous areas of coagulation necrosis between two electrodes, preferably at 3 or 4 cm inter-electrode distance for 20 min, and is better in creating large coagulation necrosis than bipolar RFA using internally cooled electrodes.


Assuntos
Ablação por Cateter/instrumentação , Temperatura Baixa , Eletrodos , Fígado/cirurgia , Análise de Variância , Animais , Temperatura Corporal/fisiologia , Ablação por Cateter/métodos , Bovinos , Desenho de Equipamento , Fígado/patologia , Necrose , Solução Salina Hipertônica/administração & dosagem , Fatores de Tempo
12.
Clin Radiol ; 60(3): 384-8, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15710143

RESUMO

AIM: To describe the pathology of focal areas of low attenuation in small gastrointestinal stromal tumours on contrast-enhanced computed tomography (CT), and to investigate the association of these areas as predictors of malignant potential. MATERIALS AND METHODS: Contrast-enhanced helical CT images were obtained of 39 small (up to 5 cm) gastrointestinal stromal tumours. Focal areas of low attenuation were retrospectively evaluated and correlated with histopathological findings. The relation between the mitotic rate of and the presence of focal areas of low attenuation in the tumours was analyzed using Fisher's exact test. RESULTS: Of the 39 small gastrointestinal stromal tumours, 15 contained focal areas of low attenuation on CT. These were found to be due to solid tumour (n=5), haemorrhage (n=3), haemorrhage with necrosis (n=2), cystic degeneration (n=2), fluid in ulcer (n=2), and fibrous septum (n=1); they were not found to be associated with a high mitotic rate (p=0.45). CONCLUSION: Focal areas of low attenuation on CT in small gastrointestinal stromal tumours represent varying pathological conditions and do not predict malignant potential.


Assuntos
Tumores do Estroma Gastrointestinal/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Tumores do Estroma Gastrointestinal/patologia , Tumores do Estroma Gastrointestinal/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
13.
Abdom Imaging ; 30(1): 90-2, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15647877

RESUMO

Calcification is a relatively uncommon manifestation of malignant liver neoplasm. Calcifications in peripheral cholangiocarcinomas but not in Klatskin tumor have been reported. We present a rare case of Klatskin tumor that had dystrophic calcification mimicking a intrahepatic stone in a 65-year-old man.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico por imagem , Ducto Hepático Comum , Tumor de Klatskin/diagnóstico por imagem , Idoso , Neoplasias dos Ductos Biliares/patologia , Calcinose , Ducto Hepático Comum/diagnóstico por imagem , Ducto Hepático Comum/patologia , Humanos , Tumor de Klatskin/patologia , Masculino , Radiografia , Ultrassonografia
14.
Br J Radiol ; 77(923): 944-9, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15507420

RESUMO

The purpose of this paper was to demonstrate the efficacy of the dual probe bipolar radiofrequency (RF) system with the perfused-cooled electrodes inducing coagulation necrosis in the ex vivo bovine liver. The perfused-cooled electrode that allows simultaneous internal cooling and interstitial hypertonic saline perfusion has been developed for RF ablation (RFA). RF was applied to excised bovine liver in a bipolar mode at 150 W using a 200 W generator with two perfused-cooled electrodes for 10 min. After placing the electrodes at 3 cm spacing in the explanted liver, 45 ablation zones were created with three different regimens: Group A, using both intraelectrode cooling and interstitial perfusion; group B, using only the intraelectrode cooling; and group C, using only interstitial perfusion. In groups A and C, RFA was performed with the infusion of 6% hypertonic saline at the rate of 2 ml min(-1). During RFA, we measured the tissue temperature at the midpoint between the two electrodes. The dimensions of the ablation zones and the changes in impedance, currents and liver temperature during RFA were compared in these three groups. The mean tissue impedance during RFA in group A (56.7+/-21.7 Omega) and group C (56.9+/-20.6 Omega) was significantly lower than group B (112+/-19.7 Omega) (p<0.001). The mean current was higher in group A (1765+/-128 mA) than groups B (760+/-321 mA) and C (1298+/-349 mA) (p<0.05). In addition, the shortest vertical diameter of coagulation necrosis was greater in groups A (4.9+/-0.5 cm) and C (4.6+/-0.7 cm) than in group B (3.5+/-0.4 cm) (p<0.05). The temperature at the mid-point between the two probes was higher in group A than other groups: 99 degrees C in group A, 88.9 degrees C in group B, and 94.3 degrees C in group C (p>0.05). The ratios of the diameter of the long-axis to the diameter of the vertical-axis of groups A, B and C were 1.1+/-0.1, 1.2+/-0.1, and 1.1+/-0.2, respectively (p<0.05). Bipolar RFA using intraelectrode cooling and the interstitial saline perfusion simultaneously produced ablation zones significantly larger than the area produced by only one measure.


Assuntos
Ablação por Cateter/instrumentação , Fígado/cirurgia , Animais , Bovinos , Temperatura Baixa , Eletrodos , Desenho de Equipamento , Fígado/patologia , Necrose
16.
Abdom Imaging ; 29(4): 491-7, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15136893

RESUMO

The purposes of this essay are to illustrate the technology overview and theoretical benefits of real-time compound ultrasonography (US) and to present our preliminary clinical experience in the evaluation of normal and diseased abdomens. The application of compounding principles to real-time US and its recent reintroduction into mainstream commercial systems have offered new opportunities for its clinical application to the routine examination of the abdomen. In our early preliminary experience, this technique effectively suppressed many of the US artifacts, better depicted the margin or boundary of the lesion, and increased contrast resolution or lesion conspicuity. Therefore, we believe that real-time compound US is a promising technique that may enhance the diagnostic confidence of the examination in the evaluation of normal and diseased abdomens.


Assuntos
Abdome/diagnóstico por imagem , Ultrassonografia/métodos , Abdome/anatomia & histologia , Humanos , Aumento da Imagem/métodos , Ilustração Médica , Fatores de Tempo , Ultrassonografia/instrumentação
17.
Abdom Imaging ; 28(5): 617-23, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14628862

RESUMO

BACKGROUND: We assessed computed tomographic (CT) features of postoperative complications and recurrent tumors in gastric cancer patients who underwent radical surgery. METHODS: We performed a retrospective study of 397 patients who had undergone radical surgery for the treatment of gastric carcinoma and underwent postoperative CT in our institution over a 2-year period. Patients were assigned to one of two groups: group A consisted of 47 patients who underwent CT for complications in the early postoperative period, and group B consisted of 355 patients who underwent CT for evidence of tumor recurrence during the follow-up period. We classified recurrent tumors into four categories: local recurrence, lymph node metastasis, peritoneal seeding, and remote metastasis. RESULTS: In group A, localized fluid collections or abscesses in the surgical bed were found in 38 patients (81%) and usually involved the left subphrenic area (74%) or the superior recess of the lesser sac (47%). In group B, recurrent tumors were found in 196 patients (55%). Among these, lymph node metastasis was the most common pattern (52%), followed by peritoneal seeding (44%), local recurrence (40%), and remote metastasis (37%). CONCLUSION: CT after radical surgery for the treatment of gastric carcinoma frequently shows postoperative complications or tumor recurrence. Familiarity with the common postoperative complications and patterns of the tumor recurrence is a prerequisite to accurate interpretation of CT findings in these patients.


Assuntos
Recidiva Local de Neoplasia/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Radiografia Intervencionista , Neoplasias Gástricas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Gastrectomia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias Gástricas/cirurgia
18.
Abdom Imaging ; 28(5): 624-30, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14628863

RESUMO

BACKGROUND: We reviewed the computed tomographic (CT) findings of afferent loop obstruction and assessed the value of helical CT in determining the underlying cause. METHODS: Helical CT scans of 18 patients (12 men and six women; age range = 35-67, mean age = 50 years) with afferent loop obstruction were reviewed. All patients had gastric cancer. Ten patients had undergone radical subtotal gastrectomy with Billroth II gastrojejunostomy, and eight had undergone total gastrectomy with Roux-en-Y esophagojejunostomy. CT images were analyzed retrospectively, and the presumed cause of obstruction on CT was compared with surgical findings (n = 8) and clinical courses (n = 10). RESULTS: Local recurrence (n = 15), peritoneal seeding (n = 1), internal hernia (n = 1), and adhesion (n = 1) were the presumed causes of obstruction on CT. In all eight patients who underwent a second operation, the cause of afferent loop obstruction was correctly suggested on CT (local recurrence in six patients and adhesion and internal hernia in one patient). In 10 patients who were not re-explored, the clinical findings or biopsy indicated recurrent tumor as suggested on CT. CONCLUSION: Recurrent tumors and other potential causes of afferent loop obstruction can be correctly predicted with CT in most cases.


Assuntos
Síndrome da Alça Aferente/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Neoplasias Gástricas/cirurgia , Tomografia Computadorizada por Raios X , Adulto , Síndrome da Alça Aferente/etiologia , Idoso , Feminino , Gastrectomia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Neoplasias Gástricas/diagnóstico por imagem
19.
Abdom Imaging ; 28(5): 652-6, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14628869

RESUMO

BACKGROUND: To optimize hepatic arterial phase timing in contrast-enhanced dynamic ultrasonography (US) of the liver. METHODS: Dynamic US was performed by using a microbubble-specific mode in 22 healthy volunteers after bolus injection of SH U 508A. Images were analyzed to determine whether hepatic arterial and portal venous phases could be temporally discriminated. Delay times to contrast enhancement at the hepatic artery (A(ini)) and portal vein (P(ini)) and the delay time until the signals between both vessels became inseparable (A(end)) were determined. RESULTS: The hepatic arterial and portal venous phases could be temporally discriminated in all subjects. A(ini), P(ini), and A(end) (mean +/- standard deviation) were 11.0 +/- 2.0, 14.8 +/- 3.6, and 22.6 +/- 5.1 s, respectively. CONCLUSION: In hepatic contrast-enhanced dynamic US, hepatic arterial phase scanning should be commenced earlier than 11 s and terminated after 23 s postinjection.


Assuntos
Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Adulto , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Polissacarídeos , Ultrassonografia
20.
Clin Radiol ; 58(8): 610-20, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12887954

RESUMO

Amyloidosis is a disease characterized by the deposition of fibrillar protein amyloid of beta-structure in organs or tissues. It is usually classified as either a primary disease or secondary to a co-existent condition, such as rheumatoid arthritis, tuberculosis, or neoplasm (particularly multiple myeloma or renal cell carcinoma). Amyloid protein deposition can be seen in a variety of organs though it occurs with higher frequency in the gastrointestinal tract, kidney, and heart. Amyloidosis can have a wide spectrum of manifestations in nearly every abdominal organ. Some of these, for example, multiple cystic submucosal masses of the stomach, amyloidosis of the gallbladder, and dirty soft tissue infiltration of the subcutaneous fat, have not yet been covered in the radiological literature. The combination of various imaging techniques and the identification of characteristic computed tomography (CT) hepatic features may help in the differentiation of amyloidosis from other infiltrative diseases; however, confirmative diagnosis can usually only be achieved by tissue biopsy.


Assuntos
Amiloidose/diagnóstico por imagem , Radiografia Abdominal/métodos , Adulto , Idoso , Colecistografia/métodos , Feminino , Humanos , Intestino Grosso/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Baço/diagnóstico por imagem , Estômago/diagnóstico por imagem , Tela Subcutânea/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia