Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bone Marrow Transplant ; 46(1): 105-9, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20383213

RESUMO

We investigated the feasibility of i.v. BU, CY and etoposide (BUCYE), followed by auto-SCT (ASCT) in patients with newly diagnosed primary central nervous system lymphoma (PCNSL). The planned treatment consisted of induction chemotherapy with five cycles of high-dose MTX and two cycles of high-dose cytarabine followed by conditioning with BUCYE (BU 3.2 mg/m², day -7 to day -5; CY 50 mg/kg, day -3 to day -2 and etoposide 200 mg/m², twice a day, days -5 and -4) and then ASCT. Between May 2005 and November 2008, 11 consecutive PCNSL patients were treated. All patients completed the treatment as planned, with no cases of treatment-related death or veno-occlusive disease. After BUCYE and ASCT, 10 patients achieved complete response (CR) or unconfirmed CR (CRu). Two patients, one partial response and one CRu, received further whole-brain radiotherapy, with all achieving CR. At a median follow-up of 25.0 months (8.8-50.7 months), six patients had relapsed, with a median event-free interval of 15.0 months (95% confidence interval, 4.5-25.6 months). Median survival time was not reached yet with a 2-year survival rate of 88.9%. The current treatment was feasible with a favorable tolerance profile. However, further regimen optimization is necessary because of high relapse rate.


Assuntos
Antineoplásicos/uso terapêutico , Bussulfano/uso terapêutico , Neoplasias do Sistema Nervoso Central/terapia , Ciclofosfamida/uso terapêutico , Etoposídeo/uso terapêutico , Transplante de Células-Tronco Hematopoéticas , Linfoma/terapia , Adulto , Idoso , Antineoplásicos/administração & dosagem , Antineoplásicos/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Bussulfano/administração & dosagem , Bussulfano/efeitos adversos , Neoplasias do Sistema Nervoso Central/tratamento farmacológico , Neoplasias do Sistema Nervoso Central/radioterapia , Terapia Combinada/efeitos adversos , Ciclofosfamida/administração & dosagem , Ciclofosfamida/efeitos adversos , Etoposídeo/administração & dosagem , Etoposídeo/efeitos adversos , Estudos de Viabilidade , Feminino , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Humanos , Linfoma/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Recidiva , Indução de Remissão , Análise de Sobrevida , Condicionamento Pré-Transplante/efeitos adversos , Condicionamento Pré-Transplante/métodos , Transplante Autólogo
3.
Med Dosim ; 26(4): 315-8, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11747997

RESUMO

Fractionated stereotactic radiotherapy (FSRT) offers a technique to minimize the absorbed dose to normal tissues; therefore, quality assurance is essential for these procedures. In this study, quality assurance for FSRT of 58 cases, between August 1995 and August 1997 are described, and the errors for each step and overall accuracy were estimated. Some of the important items for FSRT procedures are: accuracy in CT localization, transferred image distortion, laser alignment, isocentric accuracy of linear accelerator, head frame movement, portal verification, and various human errors. A geometric phantom, that has known coordinates was used to estimate the accuracy of CT localization. A treatment planning computer was used for checking the transferred image distortion. The mechanical isocenter standard (MIS), rectilinear phantom pointer: (RLPP), and laser target localizer frame (LTLF) were used for laser alignment and target coordinates setting. Head-frame stability check was performed by a depth confirmation helmet (DCH). A film test was done to check isocentric accuracy and portal verification. All measured data for the 58 patients were recorded and analyzed for each item. 4-MV x-rays from a linear accelerator, were used for FSRT, along with homemade circular cones with diameters from 20 to 70 mm (interval: 5 mm). The accuracy in CT localization was 1.2+/-0.5 mm. The isocentric accuracy of the linear accelerator, including laser alignment, was 0.5+/-0.2 mm. The reproducibility of the head frame was 1.1+/-0.6 mm. The overall accuracy was 1.7+/-0.7 mm, excluding human errors.


Assuntos
Neoplasias Encefálicas/radioterapia , Fracionamento da Dose de Radiação , Estudos de Avaliação como Assunto , Erros Médicos , Garantia da Qualidade dos Cuidados de Saúde , Técnicas Estereotáxicas , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Computação Matemática , Aceleradores de Partículas , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
5.
Phys Med Biol ; 45(11): 3367-72, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11098910

RESUMO

A modified sector-integration method is presented that can predict the output factors of irregular shaped electron fields even in the case of extended source to surface distance (SSD). The model takes as input measured output factors for circular inserts of various radii. These circular fields were measured at SSDs of 100, 105 and 110 cm to determine the effective source distance as a function of radius (ESD(r)). For an arbitrary electron field at any SSD, the shape is divided into small sectors, and the contribution calculated from the radius and ESD(r). The calculated output factors were verified by direct measurements of various types of electron fields mainly based on clinical use. The energies modelled were 8, 10 and 12 MeV for applicator sizes of 10 cm x 10 cm and 14 cm x 14 cm (defined at 95 cm). The calculated values agreed with the measured data within 1% for the various rectangular cutouts including extended source to surface distance. We retrospectively modelled 97 patient inserts of irregular shape, and found agreement within 2% of measured values.


Assuntos
Elétrons , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/métodos , Algoritmos , Modelos Estatísticos
6.
Int J Radiat Oncol Biol Phys ; 48(2): 541-4, 2000 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-10974474

RESUMO

PURPOSE: A new collimator cone system has been developed at the Samsung Medical Center that overcomes some of the limitations of present commercially supplied collimator cones. The physical properties of the newly developed cone system are described in this report. METHODS AND MATERIALS: The new cones have relatively larger aperture sizes (3.0-7.0 cm in diameter) and are 16 cm in length. Each new cone is fabricated with cerrobend alloy melted and poured into a stainless steel housing that is permanently fixed to a mounting plate. The mounting plate of the new cone is designed to insert into the wedge mount slot of the gantry head. The mechanical accuracy of the central axis of the cone pointing to the isocenter was tested using film, a steel ball positioned at the isocenter by the mechanical isocenter device. For the evaluation of beam flatness and penumbra, off-axis ratios at 5 cm depth were measured by film dosimetry using polystyrene phantom. RESULTS: The average error of the mechanical isocenter was 0.27 mm (+/- 0.16 mm). The beam flatness was excellent in the central region of the beam, and the average penumbra width was 3.35 mm (+/- 0.25 mm). The new cone design has more clearance between the patient's head and the gantry, and can more easily be removed from the gantry head because it slides in and out of the wedge slot. This facilitates changing cone sizes during one treatment session, and makes the process of double exposure port films easier. CONCLUSIONS: A new collimator cone system for stereotactic radiation therapy has been developed. The mechanical accuracy and physical properties are satisfactory for clinical use, and the new design permits a wider range of clinical applications for stereotactic radiation therapy.


Assuntos
Radiocirurgia/instrumentação , Ligas , Desenho de Equipamento , Estudos de Avaliação como Assunto , Física Médica
7.
Radiat Med ; 17(4): 289-93, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10510902

RESUMO

PURPOSE: To investigate the correlation between late rectal complications and rectal dose in uterine cervix cancer patients treated with high dose rate intracavitary radiotherapy (HDR ICR) and to analyze dose factors reducing complications. METHODS: A retrospective analysis was done of 74 patients treated with external beam RT and HDR ICR between 1995 and 1997. Radiotherapy (RT) consisted of a median 50.4 Gy external beam plus six fractions of HDR ICR given two times per week, concurrent with the last three weeks of external beam therapy, to a total dose of median 24 Gy to point A or the reference point. Rectal doses were calculated at rectal reference points using barium contrast criteria. In vivo measurement of rectal dose was performed with thermoluminescent dosimeters (TLD) immediately prior to the first fraction of HDR ICR. RESULTS: Eight patients developed rectal complications (11%). There was a significant difference between measured rectal doses for patients with rectal complications and those without (p < 0.05), and the doses were higher in complicated patients. A significant increase in the probability of development of complications was found for patients receiving measured rectal doses of ICR fractional dose 320 cGy or more, ICR total dose 2000 cGy or more, and ICR% to point A 80% or more. CONCLUSIONS: This study showed that in vivo dosimetry using TLD during HDR ICR could have a useful role as a predictor of late rectal complications. Dose limitation to the rectum could possibly be achieved by thorough vaginal packing or use of an applicator with proper shielding while maintaining a high dose to the tumor.


Assuntos
Braquiterapia/efeitos adversos , Lesões por Radiação/etiologia , Doenças Retais/etiologia , Reto/efeitos da radiação , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Lesões por Radiação/diagnóstico , Dosagem Radioterapêutica , Doenças Retais/diagnóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Taxa de Sobrevida , Neoplasias do Colo do Útero/mortalidade , Neoplasias do Colo do Útero/patologia
8.
Int J Radiat Oncol Biol Phys ; 44(2): 435-8, 1999 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-10760440

RESUMO

PURPOSE: In stereotactic radiotherapy using X-Knife system, the commercially supplied collimator cone system had a few mechanical limitations. The authors have developed new collimator cones to overcome these limitations and named them "SMC type" collimator cones. METHODS: We made use of cadmium-free cerrobend alloy within the stainless steel cylinder housing. We made nine cones of relatively larger sizes (3.0 cm to 7.0 cm in diameter) and of shorter length with bigger clearance from the isocenter than the commercial cones. The cone housing and the collimator cones were designed to insert into the wedge mount of the gantry head to enable double-exposure linac-gram taking. RESULTS: The mechanical accuracy of pointing to the isocenter was tested by ball test and cone rotation test, and the dosimetric measurements were performed, all of which were with satisfactory results. A new innovative quality assurance procedure using linac-grams on the patients at the actual treatment setup was attempted after taking 10 sets of AP and lateral linac-grams and the overall mechanical isocenter accuracy was excellent (average error = 0.4 +/- 0.2 mm). CONCLUSIONS: We have developed the SMC type collimator cone system mainly for fractionated stereotactic radiation therapy use with our innovative ideas. The new cones' mechanical accuracy and physical properties were satisfactory for clinical use, and the verification of the isocenter accuracy on the actual treatment setup has become possible.


Assuntos
Radiocirurgia/instrumentação , Ligas , Fracionamento da Dose de Radiação , Desenho de Equipamento , Fenômenos Físicos , Física , Controle de Qualidade , Radiocirurgia/normas
9.
Int J Radiat Oncol Biol Phys ; 40(3): 623-7, 1998 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-9486612

RESUMO

PURPOSE: Authors designed a customized small bowel displacement system (SBDS) to displace the small bowel out of the pelvic radiation fields and to minimize treatment related bowel morbidity. METHODS AND MATERIALS: From August 1995 to May 1996, 55 consecutive patients who received pelvic radiation therapy with the SBDS were included in this study. The SBDS consists of a customized Styrofoam compression device that can displace the small bowel out of the radiation fields and an individualized immobilization abdominal board for easy daily setup of the patient in prone position. After opacifying the small bowel with barium, the patients were laid prone and posterior-anterior (PA) and lateral (LAT) simulation films were taken with and without the SBDS. The volume of the small bowel included in the radiation fields with and without the SBDS were compared. RESULTS: Using the SBDS, the mean small bowel volume was reduced by 59% on PA and 51% on LAT films (p = 0.0001). In six patients (6 of 55, 11%), it was possible that no small bowel was included within the treatment fields. The mean upward displacement of the most caudal small bowel was 4.8 cm using the SBDS. Patients treated with the SBDS manifested a significantly lower incidence of diarrhea requiring medication (8 of 55, 15%) vs. those without the SBDS (24 of 39, 62%) (p < 0.05). CONCLUSION: The SBDS is a novel method that can be used to displace the small bowel away from the treatment portal effectively and to reduce the radiation therapy morbidity. Compliance with setup is excellent.


Assuntos
Intestino Delgado , Pelve , Radioterapia (Especialidade)/instrumentação , Adulto , Idoso , Neoplasias do Endométrio/radioterapia , Desenho de Equipamento , Feminino , Humanos , Intestino Delgado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Decúbito Ventral , Radiografia , Neoplasias Retais/radioterapia , Neoplasias do Colo do Útero/radioterapia
10.
Bioorg Med Chem Lett ; 8(12): 1547-50, 1998 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-9873387

RESUMO

Novel 1-(1-benzoylindoline-5-sulfonyl)-4-phenyl-4,5-dihydroimidazolon es 3 synthesized show highly potent and broad cytotoxicities. Among them compound 3b (DW2143) exhibits much more potent cytotoxicities than doxorubicin and highly effective antitumor activities against murine (3LL, Colon 26) and human xenograft (NCI-H23, SW620) tumor models.


Assuntos
Antineoplásicos/síntese química , Antineoplásicos/farmacologia , Imidazóis/síntese química , Imidazóis/farmacologia , Animais , Ensaios de Seleção de Medicamentos Antitumorais , Humanos , Camundongos , Sulfonas/síntese química , Sulfonas/farmacologia , Transplante Heterólogo , Células Tumorais Cultivadas
11.
Med Dosim ; 22(1): 53-8, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9136109

RESUMO

The accuracy in target localization of CT, MRI, and digital angiography and the isocentric deviation of linear accelerator were investigated for stereotactic radiosurgery. Twenty-five slice images using CT and MRI were obtained out of geometrical phantom which was designed to produce exact 3-dimensional coordinates of several points within a 0.1 mm error range. These diagnostic images were transferred to a 3-D treatment planning system through ethernet. Measured 3-D coordinates of these images from the planning system were compared to known values by geometrical phantom. Anterior-posterior and lateral films were taken by digital angiography for measurement of spatial accuracy. The accuracy of gantry isocenter aligned by laser localizer was also measured. Lead ball was located at the isocenter of linear accelerator and x-ray films were taken by 4-MV photon beam with gantry angles of 0, 90, 180 and 270 degrees, Overall procedure from CT scanning to treatment was carried out using the geometrical phantom. The target accuracy was verified by high energy x-ray portal film. The accuracy of diagnostic machines were within 2.1 mm except MR-axial images. In case of linear accelerator, the deviation of isocenter was within 0.7 mm. Finally, the total isocentric deviation of overall procedure was 1.3 +/- 0.5 mm (using CT localization).


Assuntos
Aceleradores de Partículas , Radiocirurgia , Radioterapia de Alta Energia , Angiografia Digital , Humanos , Imageamento por Ressonância Magnética , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
12.
J Nematol ; 23(2): 175-81, 1991 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19283109

RESUMO

In greenhouse experiments, massive application of the fungivorous nematode, Aphelenchus avenae, in summer at 26-33 C (1 x l0 nematodes/500 cm(3) autoclaved soil) or in autumn at 18-23 C (5 x 10 nematodes/500 cm(3) autoclaved soil) suppressed pre-emergence damping-off of cucumber seedlings due to Rhizoctonia solani AG-4 by 67% or 87%, respectively. Application of 2 x l0 A. avenae to sterilized soil infested with R. solani caused leafminer-like symptom on the cotyledons, which did not occur in mixed inoculations with the entomopathogenic nematode, Steinernema carpocapsae. When 1 x 10 A. avenae were applied 3 days before inoculation with 100 Meloidogyne incognita juveniles, gall numbers on tomato roots were reduced to 50% of controls. Gall numbers also were suppressed by S. carpocapsae (str. All). Reduction in gall numbers was no greater with mixed application of A. avenae and S. carpocapsae than with application of single species, even though twice the number of nematodes were added in the former case. These nematodes were positively attracted to tomato root tips. Aphelenchus avenae suppressed infection of the turnip moth, Agrotis segetum, but not the common cutworm, Spodoptera litura, by S. carpocapsae.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...