Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hip Pelvis ; 28(2): 82-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27536649

RESUMO

PURPOSE: The purpose of this study was to retrospectively evaluate the short-term clinical and radiological outcomes of total hip arthroplasty (THA) with short metaphyseal loading femoral stem. MATERIALS AND METHODS: We retrospectively reviewed the records of 56 cases in 47 patients who had undergone THA with short metaphyseal loading femoral stem from April 2010 to December 2011. There were 20 males and 27 females. The mean age was 54 years (range, 26-77 years). The average follow up period was 4.6 years. Clinical results were evaluated by Harris hip scores (HHS) before the operation and at the last follow-up. Radiographic analysis was done by evaluating osteolysis, loosening, stress shielding, and alignement. RESULTS: The mean HHS significantly improved from 45 (range, 15-58) preoperatively to 98 (range, 85-100) at the last follow-up. In radiographic analyses, there was no evidence of osteolysis or loosening around the stems and the acetabuluar components. All cases showed rounding off of the calcar, grade 1 bone resorption of the proximal femur. With regard to implant alignment, 51 femoral component (91.1%) were in neutral position, and 5 (8.9%) were in varus position. There was 1 intraoperative fracture treated by cerclage wiring and no case was revised during follow-up period. CONCLUSION: Although longer follow-up is needed to confirm the durability of the short metaphyseal loading femoral stem, this short stem might provide stable fixation without diaphyseal fixation and demonstrated good clinical result at mean 4.6 year short term follow-up.

2.
Arthroscopy ; 31(12): 2380-91.e2, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26343943

RESUMO

PURPOSE: To compare the relation of extrusion of the graft with the position of the allograft between the parapatellar and transpatellar approaches and to show the primary importance of an anatomically correct position by comparing the chondroprotective effects after lateral meniscal allograft transplantation (MAT) with those of normal healthy knees. METHODS: Geometrical data from patients who underwent magnetic resonance imaging evaluation after lateral MAT were used as baseline input data for 3-dimensional and finite element analysis. The inclusion criteria were patients with symptomatic knees that had undergone meniscectomy who underwent lateral MAT with a minimum follow-up of 2 years. Patients with generalized arthritis, lower limb malalignment with greater than 5° valgus or varus, or uncorrected joint instability caused by ligament structure deficiency were excluded from this study. Patients were divided into the parapatellar group (25 patients) and transpatellar group (20 patients) according to surgical approach. RESULTS: The mean width of the extruded meniscus was 4.32 ± 0.58 mm in the parapatellar group and 3.00 ± 0.61 mm in the transpatellar group (P < .0001). The mean relative percentage of extrusion was 42.48% ± 7.82% in the parapatellar group and 28.21% ± 4.49% in the transpatellar group (P < .0001). The mean angle between the bony bridge and the center of the tibial plateau was significantly greater in the parapatellar group (16.69° ± 2.68°) than in the transpatellar group (5.29° ± 1.55°, P < .0001). The mean distance from the entry point of the bony bridge to the center of the tibial plateau was also greater in the parapatellar group (16.68 ± 2.56 mm) than in the transpatellar group (10.81 ± 1.37 mm, P < .0001). The distance from the entry point of the bony bridge to the center of the tibial plateau significantly influenced the obliquity of the bony bridge in the parapatellar group (P = .002). On finite element analysis, the transpatellar approach was more similar to the intact knee model in terms of the contact area and stress of the lateral meniscus and medial meniscus as well as the maximum compressive and maximum shear stresses. Compared with the parapatellar approach, the transpatellar approach had lower maximum contact stress on the menisci and lower maximum compressive stress and maximum shear stress on the femoral and tibial articular surfaces. CONCLUSIONS: The transpatellar approach led to a more anatomically correct positioning of the grafted meniscus with less meniscal extrusion than did the parapatellar approach in lateral MAT. Furthermore, the transpatellar model had lower maximum contact stress on the menisci than did the parapatellar model, and it also had lower maximum compressive stress and maximum shear stress on the femoral and tibial articular surfaces. CLINICAL RELEVANCE: The transpatellar approach is likely to have a more anatomic placement of graft with a subsequent greater chondroprotective effect; thereby, it may reduce the overall risk of degenerative osteoarthritis after lateral MAT.


Assuntos
Instabilidade Articular/diagnóstico , Articulação do Joelho/cirurgia , Meniscos Tibiais/cirurgia , Patela/cirurgia , Transplante Homólogo/efeitos adversos , Aloenxertos , Fenômenos Biomecânicos , Fêmur/cirurgia , Análise de Elementos Finitos , Sobrevivência de Enxerto , Humanos , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Articulação do Joelho/fisiopatologia , Imageamento por Ressonância Magnética , Meniscos Tibiais/fisiopatologia , Procedimentos de Cirurgia Plástica , Estudos Retrospectivos , Estresse Mecânico , Tíbia/cirurgia
3.
J Arthroplasty ; 24(6): 885-91, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18617363

RESUMO

This study compared the clinical and radiographic results and the prevalence of osteolysis between alumina-on-alumina and alumina-on-highly cross-linked polyethylene bearings after cementless total hip arthroplasties in the 100 patients younger than 50 years of age. There were 66 men and 34 women; the mean age at the time of surgery was 45.3 years (range, 25 to 49 years). The mean duration of follow-up was 5.6 years (range, five to seven years). The pre-and postoperative Harris hip scores were similar (39 and 41 points, respectively and 93 points and 94 points, respectively). No acetabular or femoral component had aseptic loosening in either group. The mean annual penetration of the highly cross-linked polyethylene was 0.06 +/- 0.03 mm. No hip in either group had acetabular or femoral osteolysis.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril/instrumentação , Prótese de Quadril , Osteonecrose/cirurgia , Polietileno , Adulto , Óxido de Alumínio/efeitos adversos , Artroplastia de Quadril/métodos , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiologia , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Osteólise/epidemiologia , Polietileno/efeitos adversos , Radiografia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...