Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomech Eng ; 145(12)2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37796636

RESUMO

Model reproducibility is a point of emphasis for the National Institutes of Health (NIH) and in science, broadly. As the use of computational modeling in biomechanics and orthopedics grows, so does the need to assess the reproducibility of modeling workflows and simulation predictions. The long-term goal of the KneeHub project is to understand the influence of potentially subjective decisions, thus the modeler's "art", on the reproducibility and predictive uncertainty of computational knee joint models. In this paper, we report on the model calibration phase of this project, during which five teams calibrated computational knee joint models of the same specimens from the same specimen-specific joint mechanics dataset. We investigated model calibration approaches and decisions, and compared calibration workflows and model outcomes among the teams. The selection of the calibration targets used in the calibration workflow differed greatly between the teams and was influenced by modeling decisions related to the representation of structures, and considerations for computational cost and implementation of optimization. While calibration improved model performance, differences in the postcalibration ligament properties and predicted kinematics were quantified and discussed in the context of modeling decisions. Even for teams with demonstrated expertise, model calibration is difficult to foresee and plan in detail, and the results of this study underscore the importance of identification and standardization of best practices for data sharing and calibration.


Assuntos
Articulação do Joelho , Fluxo de Trabalho , Reprodutibilidade dos Testes , Calibragem , Fenômenos Biomecânicos , Simulação por Computador , Análise de Elementos Finitos
2.
J Orthop Res ; 41(2): 325-334, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35502762

RESUMO

Reproducible research serves as a pillar of the scientific method and is a foundation for scientific advancement. However, estimates for irreproducibility of preclinical science range from 75% to 90%. The importance of reproducible science has not been assessed in the context of mechanics-based modeling of human joints such as the knee, despite this being an area that has seen dramatic growth. Framed in the context of five experienced teams currently documenting knee modeling procedures, the aim of this study was to evaluate reporting and the perceived potential for reproducibility across studies the teams viewed as important contributions to the literature. A cohort of studies was selected by polling, which resulted in an assessment of nine studies as opposed to a broader analysis across the literature. Using a published checklist for reporting of modeling features, the cohort was evaluated for both "reporting" and their potential to be "reproduced," which was delineated into six major modeling categories and three subcategories. Logistic regression analysis revealed that for individual modeling categories, the proportion of "reported" occurrences ranged from 0.31, 95% confidence interval (CI) [0.23, 0.41] to 0.77, 95% CI: [0.68, 0.86]. The proportion of whether a category was perceived as "reproducible" ranged from 0.22, 95% CI: [0.15, 0.31] to 0.44, 95% CI: [0.35, 0.55]. The relatively low ratios highlight an opportunity to improve reporting and reproducibility of knee modeling studies. Ongoing efforts, including our findings, contribute to a dialogue that facilitates adoption of practices that provide both credibility and translation possibilities.


Assuntos
Articulação do Joelho , Joelho , Humanos , Fenômenos Biomecânicos , Reprodutibilidade dos Testes
3.
Ann Biomed Eng ; 51(1): 10-23, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36104640

RESUMO

There is a growing interest in the use of virtual representations of the knee for musculoskeletal research and clinical decision making, and to generate digital evidence for design and regulation of implants. Accessibility to previously developed models and related digital assets can dramatically reduce barriers to entry to conduct simulation-based studies of the knee joint and therefore help accelerate scientific discovery and clinical innovations. Development of models for finite element analysis is a demanding process that is both time consuming and resource intensive. It necessitates expertise to transform raw data to reliable virtual representations. Modeling and simulation workflow has many processes such as image segmentation, surface geometry generation, mesh generation and finally, creation of a finite element representation with relevant loading and boundary conditions. The outcome of the workflow is not only the end-point knee model but also many other digital by-products. When all of these data, derivate assets, and tools are freely and openly accessible, researchers can bypass some or all the steps required to build models and focus on using them to address their research goals. With provenance to specimen-specific anatomical and mechanical data and traceability of digital assets throughout the whole lifecycle of the model, reproducibility and credibility of the modeling practice can be established. The objective of this study is to disseminate Open Knee(s), a cohort of eight knee models (and relevant digital assets) for finite element analysis, that are based on comprehensive specimen-specific imaging data. In addition, the models and by-products of modeling workflows are described along with model development strategies and tools. Passive flexion served as a test simulation case, demonstrating an end-user application. Potential roadmaps for reuse of Open Knee(s) are also discussed.


Assuntos
Articulação do Joelho , Joelho , Humanos , Análise de Elementos Finitos , Reprodutibilidade dos Testes , Fenômenos Biomecânicos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiologia
4.
J Biomech Eng ; 143(11)2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34041519

RESUMO

Accurately capturing the bone and cartilage morphology and generating a mesh remains a critical step in the workflow of computational knee joint modeling. Currently, there is no standardized method to compare meshes of different element types and nodal densities, making comparisons across research teams a significant challenge. The aim of this paper is to describe a method to quantify differences in knee joint bone and cartilages meshes, independent of bone and cartilage mesh topology. Bone mesh-to-mesh distances, subchondral bone boundaries, and cartilage thicknesses from meshes of any type of mesh are obtained using a series of steps involving registration, resampling, and radial basis function fitting after which the comparisons are performed. Subchondral bone boundaries and cartilage thicknesses are calculated and visualized in a common frame of reference for comparison. The established method is applied to models developed by five modeling teams. Our approach to obtain bone mesh-to-mesh distances decreased the divergence seen in selecting a reference mesh (i.e., comparing mesh A-to-B versus mesh B-to-A). In general, the bone morphology was similar across teams. The cartilage thicknesses for all models were calculated and the mean absolute cartilage thickness difference was presented, the articulating areas had the best agreement across teams. The teams showed disagreement on the subchondral bone boundaries. The method presented in this paper allows for objective comparisons of bone and cartilage geometry that is agnostic to mesh type and nodal density.


Assuntos
Articulação do Joelho
5.
Data Brief ; 35: 106824, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33659588

RESUMO

Virtual knees, with specimen-specific anatomy and mechanics, require heterogeneous data collected on the same knee. Specimen-specific data such as the specimen geometry, physiological joint kinematics-kinetics and contact mechanics are necessary in the development of virtual knee specimens for clinical and scientific simulations. These data are also required to capture or evaluate the predictive capacity of the model to represent joint and tissue mechanical response. This document details the collection of magnetic resonance imaging data and, tibiofemoral joint and patellofemoral joint mechanical testing data. These data were acquired for a cohort of eight knee specimens representing different populations with varying gender, age and perceived health of the joint. These data were collected as part of the Open Knee(s) initiative. Imaging data when combined with joint mechanics data, may enable development and assessment of authentic specimen-specific finite element models of the knee. The data may also guide prospective studies for association of anatomical and biomechanical markers in a specimen-specific manner.

6.
J Biomech Eng ; 143(6)2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33537727

RESUMO

The use of computational modeling to investigate knee joint biomechanics has increased exponentially over the last few decades. Developing computational models is a creative process where decisions have to be made, subject to the modelers' knowledge and previous experiences, resulting in the "art" of modeling. The long-term goal of the KneeHub project is to understand the influence of subjective decisions on the final outcomes and the reproducibility of computational knee joint models. In this paper, we report on the model development phase of this project, investigating model development decisions and deviations from initial modeling plans. Five teams developed computational knee joint models from the same dataset, and we compared each teams' initial uncalibrated models and their model development workflows. Variations in the software tools and modeling approaches were found, resulting in differences such as the representation of the anatomical knee joint structures in the model. The teams consistently defined the boundary conditions and used the same anatomical coordinate system convention. However, deviations in the anatomical landmarks used to define the coordinate systems were present, resulting in a large spread in the kinematic outputs of the uncalibrated models. The reported differences and similarities in model development and simulation presented here illustrate the importance of the "art" of modeling and how subjective decision-making can lead to variation in model outputs. All teams deviated from their initial modeling plans, indicating that model development is a flexible process and difficult to plan in advance, even for experienced teams.


Assuntos
Articulação do Joelho
7.
J Mech Behav Biomed Mater ; 112: 104025, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32841833

RESUMO

Articular cartilage mechanics has been extensively studied with various approaches and mechanical characterization strategies. However testing protocols can be highly varying and difficult to reproduce, particularly for specimen-specific analyses. Detailed knowledge of testing protocols is important for reliable use in concordant finite element analyses. This study presents a detailed, robust procedure for cartilage testing-with multiple regions and per sample repeatability data. Samples were taken from femur, tibia and patella of a human cadaver knee and tested in unconfined compression, confined compression and uniaxial tension. Each test was repeated three times. The testing protocols provide elastic and time dependent characterization data. Results, for example equilibrium modulus of 0.28 (0.0024) MPa for patella under unconfined compression indicate that variability is well controlled and that protocol(s) presented here can generate repeatable specimen-specific data. As per the authors' knowledge this is the first study to report in-depth uncertainty assessment of the experimental procedures for multi-region knee cartilage characterization.


Assuntos
Cartilagem Articular , Articulação do Joelho , Elasticidade , Análise de Elementos Finitos , Humanos , Patela , Estresse Mecânico
8.
PLoS One ; 10(9): e0138226, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26381404

RESUMO

Understanding of tibiofemoral joint mechanics at multiple spatial scales is essential for developing effective preventive measures and treatments for both pathology and injury management. Currently, there is a distinct lack of specimen-specific biomechanical data at multiple spatial scales, e.g., joint, tissue, and cell scales. Comprehensive multiscale data may improve the understanding of the relationship between biomechanical and anatomical markers across various scales. Furthermore, specimen-specific multiscale data for the tibiofemoral joint may assist development and validation of specimen-specific computational models that may be useful for more thorough analyses of the biomechanical behavior of the joint. This study describes an aggregation of procedures for acquisition of multiscale anatomical and biomechanical data for the tibiofemoral joint. Magnetic resonance imaging was used to acquire anatomical morphology at the joint scale. A robotic testing system was used to quantify joint level biomechanical response under various loading scenarios. Tissue level material properties were obtained from the same specimen for the femoral and tibial articular cartilage, medial and lateral menisci, anterior and posterior cruciate ligaments, and medial and lateral collateral ligaments. Histology data were also obtained for all tissue types to measure specimen-specific cell scale information, e.g., cellular distribution. This study is the first of its kind to establish a comprehensive multiscale data set for a musculoskeletal joint and the presented data collection approach can be used as a general template to guide acquisition of specimen-specific comprehensive multiscale data for musculoskeletal joints.


Assuntos
Simulação por Computador , Fêmur/fisiologia , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/fisiologia , Modelos Biológicos , Tíbia/fisiologia , Fenômenos Biomecânicos , Cartilagem Articular/anatomia & histologia , Cartilagem Articular/fisiologia , Fêmur/anatomia & histologia , Humanos , Traumatismos do Joelho/patologia , Traumatismos do Joelho/fisiopatologia , Imageamento por Ressonância Magnética , Amplitude de Movimento Articular/fisiologia , Estresse Mecânico , Tíbia/anatomia & histologia
9.
J Biomech Eng ; 134(3): 031002, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22482682

RESUMO

Quantification of plantar tissue behavior of the heel pad is essential in developing computational models for predictive analysis of preventive treatment options such as footwear for patients with diabetes. Simulation based studies in the past have generally adopted heel pad properties from the literature, in return using heel-specific geometry with material properties of a different heel. In exceptional cases, patient-specific material characterization was performed with simplified two-dimensional models, without further evaluation of a heel-specific response under different loading conditions. The aim of this study was to conduct an inverse finite element analysis of the heel in order to calculate heel-specific material properties in situ. Multidimensional experimental data available from a previous cadaver study by Erdemir et al. ("An Elaborate Data Set Characterizing the Mechanical Response of the Foot," ASME J. Biomech. Eng., 131(9), pp. 094502) was used for model development, optimization, and evaluation of material properties. A specimen-specific three-dimensional finite element representation was developed. Heel pad material properties were determined using inverse finite element analysis by fitting the model behavior to the experimental data. Compression dominant loading, applied using a spherical indenter, was used for optimization of the material properties. The optimized material properties were evaluated through simulations representative of a combined loading scenario (compression and anterior-posterior shear) with a spherical indenter and also of a compression dominant loading applied using an elevated platform. Optimized heel pad material coefficients were 0.001084 MPa (µ), 9.780 (α) (with an effective Poisson's ratio (ν) of 0.475), for a first-order nearly incompressible Ogden material model. The model predicted structural response of the heel pad was in good agreement for both the optimization (<1.05% maximum tool force, 0.9% maximum tool displacement) and validation cases (6.5% maximum tool force, 15% maximum tool displacement). The inverse analysis successfully predicted the material properties for the given specimen-specific heel pad using the experimental data for the specimen. The modeling framework and results can be used for accurate predictions of the three-dimensional interaction of the heel pad with its surroundings.


Assuntos
Análise de Elementos Finitos , Calcanhar , Elasticidade , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Estresse Mecânico
10.
J Neurophysiol ; 103(5): 2400-16, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20164397

RESUMO

Although the nature of gaze control regulating single saccades is relatively well documented, how such control is implemented to regulate multisaccade gaze shifts is not known. We used highly eccentric targets to elicit multisaccade gaze shifts and tested the ability of subjects to control the saccade sequence by presenting a second target on random trials. Their response allowed us to test the nature of control at many levels: before, during, and between saccades. Although the saccade sequence could be inhibited before it began, we observed clear signs of truncation of the first saccade, which confirmed that it could be inhibited in midflight as well. Using a race model that explains the control of single saccades, we estimated that it took about 100 ms to inhibit a planned saccade but took about 150 ms to inhibit a saccade during its execution. Although the time taken to inhibit was different, the high subject-wise correlation suggests a unitary inhibitory control acting at different levels in the oculomotor system. We also frequently observed responses that consisted of hypometric initial saccades, followed by secondary saccades to the initial target. Given the estimates of the inhibitory process provided by the model that also took into account the variances of the processes as well, the secondary saccades (average latency approximately 215 ms) should have been inhibited. Failure to inhibit the secondary saccade suggests that the intersaccadic interval in a multisaccade response is a ballistic stage. Collectively, these data indicate that the oculomotor system can control a response until a very late stage in its execution. However, if the response consists of multiple movements then the preparation of the second movement becomes refractory to new visual input, either because it is part of a preprogrammed sequence or as a consequence of being a corrective response to a motor error.


Assuntos
Modelos Neurológicos , Desempenho Psicomotor/fisiologia , Movimentos Sacádicos/fisiologia , Adolescente , Adulto , Simulação por Computador , Medições dos Movimentos Oculares , Humanos , Funções Verossimilhança , Método de Monte Carlo , Atividade Motora/fisiologia , Testes Neuropsicológicos , Probabilidade , Tempo de Reação , Reprodutibilidade dos Testes , Processos Estocásticos , Fatores de Tempo , Volição/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...