Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Orthop Surg ; 13(2): 168-174, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34094007

RESUMO

BACKGROUD: In this study, we report satisfactory clinical and radiological outcomes after autologous oblique structural peg bone and cancellous chip bone grafting without metal augmentation, including the use of a metal wedge, block, or additional stem, for patients with ≥ 10-mm-deep uncontained medial proximal tibial bone defects in primary total knee replacement. METHODS: The study group included 40 patients with primary total knee replacement with ≥ 10-mm-deep uncontained tibial bone defects who underwent autologous oblique structural peg bone and cancellous chip bone grafting and were followed-up for at least 1 year. Tibial cutting was performed up to a depth of 10 mm from the articular surface of the lateral tibial condyle, after which the height and area of the remaining bone defect in the medial condyle were measured. The bone defect was treated by making a peg bone and chip bone using excised segments of the tibia and femur. In all cases, the standard tibial stem and full cemented fixation techniques were used without metal augmentation. Preoperative and final follow-up radiologic changes and clinical measures were compared, and prosthesis loosening and bone union were checked radiologically at final follow-up. RESULTS: The mean depth of the bone defects was 10.9 mm, and the mean percentage of the area occupied by bone defects in the axial plane was 18.4%. The mean mechanical femorotibial angle was corrected from 19.5° varus preoperatively to 0.2° varus postoperatively (p < 0.002). There was no prosthesis loosening, and all cases showed bone union at the 1-year postoperative follow-up. CONCLUSIONS: Even in patients with uncontained tibial bone defects ≥ 10-mm deep in primary total knee replacement, if the defect occupies less than 30% of the cut surface, autologous oblique structural peg bone and cancellous chip bone grafting can be used to achieve satisfactory outcomes with a standard tibial stem and no metal augmentation.


Assuntos
Artroplastia do Joelho/métodos , Transplante Ósseo/métodos , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Tíbia/cirurgia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Prospectivos , Transplante Autólogo
2.
Arthroscopy ; 36(6): 1612-1624, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31785390

RESUMO

PURPOSE: The purpose of this study was to evaluate the clinical efficacy and safety of treating patients with a cartilage defect of the knee with microfractures and porcine-derived collagen-augmented chondrogenesis technique (C-ACT). METHODS: One hundred participants were randomly assigned to the control group (n = 48, microfracture) or the investigational group (n = 52, C-ACT). Clinical and magnetic resonance imaging (MRI) outcomes were assessed 12 and 24 months postoperatively for efficacy and adverse events. Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) assessment was used to analyze cartilage tissue repair. MRI outcomes for 50% defect filling and repaired tissue/reference cartilage (RT/RC) ratio were quantified using T2 mapping. Clinical outcomes were assessed using the visual analogue scale (VAS) for pain and 20% improvement, minimal clinically important difference (MCID), and patient acceptable symptom state for Knee Injury and Osteoarthritis Outcome Score (KOOS) and the International Knee Documentation Committee score. RESULTS: MOCART scores in the investigation group showed improved defect repair and filling (P = .0201), integration with the border zone (P = .0062), and effusion (P = .0079). MRI outcomes showed that the odds ratio (OR) for ≥50% defect filling at 12 months was statistically higher in the investigation group (OR 3.984, P = .0377). Moreover, the likelihood of the RT/RC OR becoming ≥1 was significantly higher (OR 11.37, P = .0126) in the investigation group. At 24 months postoperatively, the OR for the VAS 20% improvement rate was significantly higher in the investigational group (OR 2.808, P = .047). Twenty-three patients (52.3%) in the control group and 35 (77.8%) in the investigation group demonstrated more than the MCID of KOOS pain from baseline to 1 year postoperatively, with a significant difference between groups (P = .0116). CONCLUSION: In this multicenter randomized trial, the addition of C-ACT resulted in better filling of cartilage defect of the knee joint. LEVEL OF EVIDENCE: Level Ⅰ, Multicenter Randomized Controlled Trial.


Assuntos
Doenças das Cartilagens/terapia , Cartilagem Articular/transplante , Condrogênese/fisiologia , Colágeno/farmacologia , Fraturas de Estresse/terapia , Articulação do Joelho/cirurgia , Animais , Doenças das Cartilagens/complicações , Doenças das Cartilagens/diagnóstico , Feminino , Seguimentos , Fraturas de Estresse/etiologia , Fraturas de Estresse/patologia , Humanos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Suínos , Transplante Autólogo , Resultado do Tratamento
3.
Clin Orthop Surg ; 11(4): 416-421, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31788164

RESUMO

BACKGROUND: We investigated whether the patellar tilt angle influences the maximum knee flexion after total knee arthroplasty (TKA) performed by using a posterior cruciate ligament-substituting (PS) fixed-bearing prosthesis in patients with relatively loose or tight flexion gap. METHODS: In this prospective cohort study, we followed up 169 patients for at least 2 years after TKA using PS fixed-bearing prosthesis. The patients were divided into two groups according to the flexion gap value-calculated by subtracting the thickness of the final bearing from the flexion gap measured intraoperatively under 200-cN·m force after patellar reduction and insertion of the final femoral and tibial components-into a relatively tight group (group T; 3-6.5 mm) and a relatively loose group (group L; 7-11 mm). Patellar tilt angles and maximum non-weight-bearing active knee flexion angles were assessed postoperatively. Group T was further divided into subgroup Tn if the patellar tilt angle was < 5° and subgroup Tw if the angle was ≥ 5°. Pearson correlation test was used for the correlation analysis of the flexion gap, patellar tilt angle, and postoperative flexion range. RESULTS: The mean postoperative flexion was 137.3° in group T and 137.5° in group L. The mean patellar tilt angle was 6.5° in group T and 6.9° in group L. In group T, a strong negative correlation (r = -0.78, p < 0.05) was observed between the patellar tilt and postoperative flexion range. However, further analysis revealed that only the subgroup Tw showed a strong negative correlation (r = -0.76, p < 0.05). Significant correlations were not found in the subgroup Tn and group L. CONCLUSIONS: In TKA where a relatively tight flexion gap (≤ 6.5 mm) is created because of concerns about postoperative flexion instability due to a loose flexion gap, the patellar tilt angle should be < 5° for maximal postoperative knee flexion.


Assuntos
Artroplastia do Joelho , Articulação Patelofemoral/fisiopatologia , Amplitude de Movimento Articular , Feminino , Humanos , Masculino , Articulação Patelofemoral/diagnóstico por imagem , Ligamento Cruzado Posterior/cirurgia , Estudos Prospectivos , Radiografia
4.
Clin Orthop Surg ; 11(2): 244-248, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31156779

RESUMO

In comminuted patellar fractures, we performed modified tension band wiring using a FiberWire (Arthrex) instead of the conventional methods. From March 2016 to March 2018, 63 patients with patellar fractures who needed surgical treatment were treated with modified tension band wiring using two Kirschner wires (K-wires) and FiberWire. We inserted two 1.6-mm K-wires perpendicular to the fracture line after accurate reduction. With the knee flexed over 90°, we sutured around the patella using a FiberWire. Visual analog scale score and Levack's score were improved postoperatively. The mean bone union time was 5.6 months. None of the patients had breakage of wires, and nonunion with deformity occurred in one patient. We think that our method can be easier to handle and reduce irritation or breakage of the wires than conventional methods. In addition, early rehabilitation can be allowed. Therefore, we suggest that this method could be a useful method for the treatment of patellar fractures.


Assuntos
Fios Ortopédicos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Fraturas Cominutivas/cirurgia , Patela/lesões , Patela/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Clin Orthop Surg ; 8(2): 157-63, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27247740

RESUMO

BACKGROUND: We investigated the causes of impingement between the patella bone and the bearing post during high flexion in cruciate-substituting total knee arthroplasty and proposed a treatment strategy. METHODS: This prospective cohort study included 218 cases that had undergone cruciate-substituting total knee arthroplasty from February 2014 to January 2015; a single surgeon performed the operation using the same method without patellar resurfacing in all patients. RESULTS: In these patients, the occurrence of impingement was determined by performing more than 120° high knee flexion after inserting a bearing perioperatively. The incidence of impingement was significantly associated with bearing design, femoral implant size, patella bone length, and patella inferior pole angle (p < 0.05). The impingement was resolved by resection of the lower articular side of the patella bone. CONCLUSIONS: In the cruciate-substituting high-flexion total knee arthroplasty, impingement between the patella bone and bearing post was more common in patients with mobile bearing, small-size femoral component, and a long patella or a large inferior pole angle. In cases of intraoperative impingement between the patella bone and the bearing post, resection in the lower portion of the patella prevented impingement of the bearing with soft tissue or the patella by widening the space between the patella and the bearing post, which in turn prevented postoperative reduction in range of motion.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Patela/fisiopatologia , Complicações Pós-Operatórias , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/estatística & dados numéricos , Feminino , Humanos , Prótese do Joelho/efeitos adversos , Prótese do Joelho/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Amplitude de Movimento Articular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...