Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Nucl Med ; 21(3): 159-66, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17561587

RESUMO

OBJECTIVE: The aim of this study was to compare gated blood pool single photon emission computed tomography (SPECT) (GBPS) and multidetector row computed tomography (MDCT) for the determination of right ventricular ejection fraction (RVEF) and right ventricular volumes (RVV) and to compare first-pass radionuclide angiography (FP-RNA) as the gold standard. METHODS: Twenty consecutive patients (11 men, 9 women) referred for MDCT for the evaluation of the presence of coronary artery disease underwent FP-RNA and GBPS. RESULTS: The mean right ventricular end-diastolic volume (EDV) calculated with GBPS revealed a statistically significant lower value than that of MDCT. The mean right ventricular end-systolic volume (ESV) calculated with GBPS was also lower than that of MDCT. A comparison of right ventricular EDV from GBPS and MDCT yielded a correlation coefficient of 0.5972. Right ventricular ESV between GBPS and MDCT showed a correlation coefficient of 0.5650. The mean RVEFs calculated with FP-RNA (39.8% +/- 4.0%), GBPS (43.7% +/-6.9%0), and MDCT (40.4% + 7.7%) showed no statistical differences (Kruskal-Wallis statistics 4.538, P = 0.1034). A comparison of RVEFs from FP-RNA and GBPS yielded a correlation coefficient of 0.7251; RVEFs between FP-RNA and MDCT showed a correlation coefficient of 0.6166 and between GBPS and MDCT showed a correlation coefficient of 0.6367. CONCLUSION: The RVEF, EDV, and ESV calculated by GBPS had good correlation with those obtained with MDCT. In addition, there were no statistical differences of RVEF calculated from FP-RNA, GBPS, and MDCT. However, with regard to RVV, EDV and ESV from GBPS revealed statistically significantly lower values than those of MDCT. Although reasonable correlations among these modalities were obtained, the agreement among these three modalities was not good enough for interchangeable use in the clinical setting. Also, these results should be confirmed in patients with cardiac diseases in future larger population-based studies.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada Espiral/métodos , Disfunção Ventricular Direita/diagnóstico por imagem , Ventriculografia de Primeira Passagem/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada Espiral/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...