Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dis Esophagus ; 26(1): 91-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22394249

RESUMO

The purpose of this study is to apply combined multichannel intraluminal impedance and esophageal manometry (MII-EM) to test esophageal function during solid swallowing in a normal healthy population. We determined whether combined MII-EM with solid bolus is more sensitive than that with viscous bolus in the detection of motility abnormality. Eighteen healthy volunteers (11 men and 7 women; mean age 22 years, range 20-26 years) underwent combined MII-EM with a catheter containing four impedance-measuring segments and five solid-state pressure transducers. Each subject received 10 viscous and 10 solid materials. Tracings were analyzed manually for bolus presence time, total bolus transit time, contraction amplitude, duration, and onset velocity. Three hundred and sixty swallows including viscous and solid materials were analyzed. Contraction amplitude for the viscous swallows was higher at 20 cm above the lower esophageal sphincter (LES) (P= 0.049) but lower at 15 cm above the LES (P < 0.001). Duration of contractions for the solid swallows was longer at 15 cm (P= 0.002) and 10 cm above the LES (P= 0.011) compared with viscous swallows. The total bolus transit time for solid was significantly shorter than that for viscous boluses (6.8 vs. 7.7 seconds, P < 0.001). Bolus presence time appeared to be similar between viscous and solid boluses (except in the proximal esophagus). The percentage of swallows with ineffective peristalsis by manometry, as well as those with incomplete bolus transit by impedance, did not differ between viscous and solid swallows. The proportion of manometrically ineffective solid swallows with incomplete bolus transit was greater than that of viscous swallows (62.1% vs. 34.8%, P= 0.05). Application of solid boluses may potentially enhance diagnostic capability of esophageal function testing. Solid boluses can be regarded as a valuable complement to viscous boluses in the detection of esophageal motility abnormalities when applied with combined MII-EM.


Assuntos
Deglutição/fisiologia , Trânsito Gastrointestinal/fisiologia , Peristaltismo/fisiologia , Adulto , Impedância Elétrica , Feminino , Alimentos , Humanos , Masculino , Manometria/métodos , Valores de Referência , Estudos de Amostragem , Adulto Jovem
2.
Br J Radiol ; 83(988): e83-5, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20335438

RESUMO

CT-guided transthoracic lung biopsy is becoming a widely accepted procedure for the diagnosis of pulmonary lesions. The rate of severe complications following such a procedure has been reported. Of these complications, air embolism is the most likely to be fatal. We report a case of right coronary air embolism resulting in myocardial infarction after a CT-guided percutaneous needle biopsy of the lung. The patient died from underlying malignant disease 4 months later.


Assuntos
Biópsia por Agulha/efeitos adversos , Vasos Coronários , Embolia Aérea/etiologia , Neoplasias Pulmonares/patologia , Pulmão/patologia , Infarto do Miocárdio/etiologia , Adulto , Aorta , Biópsia por Agulha/métodos , Embolia Aérea/diagnóstico por imagem , Evolução Fatal , Humanos , Masculino , Radiografia Intervencionista , Tomografia Computadorizada por Raios X
3.
Br J Radiol ; 79(947): e187-9, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17065285

RESUMO

The coexistence of multiple and synchronous primary neoplasms in the genitourinary system has only rarely been described in the literature. We present the case of a 78-year-old man with haematuria as the initial presentation, finally proven to be transitional cell carcinoma (TCC) combined with renal cell carcinoma (RCC). Intravenous urography (IVU), CT and arterial angiography studies revealed a space-occupying nodule at the right upper renal pelvicalyces showing mild enhancement with contrast medium. Another strong contrast medium enhancing exophytic tumour was found at the lower pole of kidney; there were hypodense foci and calcified components in this lesion. A right nephroureterectomy was performed. Pathological diagnosis was a papillary TCC and a clear cell type RCC. This is a rare case of combined renal malignancies diagnosed by imaging.


Assuntos
Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células de Transição/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Neoplasias Primárias Múltiplas/diagnóstico por imagem , Idoso , Humanos , Masculino , Tomografia Computadorizada por Raios X
4.
Br J Radiol ; 79(942): 526-8, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16714757

RESUMO

Penile lymphoma is extremely rare and secondary involvement of the penis by lymphoma may be due to retrograde spread or to direct extension from neighbouring organ. The appearance of penile lymphoma varies and can be mistaken for other soft tissue tumours. We report on a case with malignant lymphoma of the penis. MRI findings revealed soft-tissue mass of homogeneous isointensity around the middle to distal part of penis on T(1) weighted imaging and T(2) weighted imaging. It was well encapsulated, minimally enhanced and distinct from corpus cavernosum and corpus spongiosum.


Assuntos
Linfoma de Células B/diagnóstico , Neoplasias Penianas/diagnóstico , Idoso , Humanos , Imageamento por Ressonância Magnética , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...