Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 13356, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38858406

RESUMO

Under the presence of nonlinear load, the most existing virtual impedance (VI) methods-based control solution performs poorly in reactive power sharing among droop-operated VSIs in microgrids (MGs). This may be due to the involved estimation techniques for extracting the current harmonics at selected frequencies, which suffer from either poor accuracy of the harmonic estimation and/or the effect of DC offset in the measurements. Such an issue may affect the performance of the virtual impedance control, hence, the system stability. To bridge this gap, the implementation of the virtual impedance based on multiple enhanced second-order generalized integrator (MESOGI) suitable for harmonics and DC-offset estimation/rejection, is proposed in this paper. The MESOGI can offer an accurate estimation of the current quadrature components free from DC offset at selected frequencies, required to implement the virtual impedance control. Therefore, it makes the designed virtual impedance-based control scheme robust to voltage distortions, immune to DC disturbance, and capable of sharing properly the power harmonics. As a result, this may contribute to improving the reactive and harmonic power-sharing between droop-controlled VSIs within an islanded MG. The modeling of the MESOGI scheme and its performance investigation is carried out. In addition, the mathematical model of the implemented virtual impedance is derived. Further, analysis based on the obtained model of the equivalent output impedance including virtual impedance is established to study its effect. Simulation and experimental tests are performed to prove the effectiveness of the control proposal in improving the reactive power sharing under nonlinear load operating conditions.

2.
Sci Rep ; 12(1): 10637, 2022 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-35739302

RESUMO

One of the major challenges in photovoltaic (PV) systems is extracting the maximum power from the PV array, especially when they operate under partial shading conditions (PSCs). To address this challenge, this paper introduces a novel hybrid maximum power point tracking (MPPT) method based on grey wolf optimization and particle swarm optimization (GWO-PSO) techniques. The developed MPPT technique not only avoids the common disadvantages of conventional MPPT techniques (such as perturb and observe (P&O) and incremental conductance) but also provides a simple and robust MPPT scheme to effectively handle partial shading in PV systems, since it requires only two control parameters, and its convergence to the global maximum power point (GMPP) is independent of the search process's initial conditions. The feasibility and effectiveness of the hybrid GWO-PSO-based MPPT method are verified via a co-simulation technique that combines MATLAB/SIMULINK and PSIM software environments, while comparing its performance against GWO, PSO and P&O based MPPT methods. The simulation results carried out under dynamic environmental conditions have shown the satisfactory effectiveness of the hybrid MPPT method in terms of tracking accuracy, convergence speed to GMPP and efficiency, compared to other methods.

3.
ISA Trans ; 105: 278-295, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32482466

RESUMO

DC microgrids are gaining more and more popularity and are becoming a more viable alternative to AC microgrids (MGs) due to their advantages in terms of simpler power converter stages, flexible control algorithms and the absence of synchronization and reactive power. However, DC-MGs are prone to instability issues associated with the presence of nonlinear loads such as constant power loads (CPL) known by their incremental negative impedance (INI), which may lead to voltage collapse of the main DC Bus. In this paper, H∞-based controller of a source side buck converter is designed to avoid the instability issues caused by the load-side converter acting as a CPL. Besides, the proposed controller allows a perfect rejection of all perturbations that may arise from parameter variations, input voltage and CPL current fluctuations. The design process of H∞-based controller is based on the Golver Doyle Optimization Algorithm (GDOA), which requires an augmented system extracted from the small-signal model of the DC/DC converter including the mathematical model of parameter variations and overall external perturbations. The​ H∞ based controller involves the use of weight functions in order to get the desired performances. The proposed controller is easy to implement and lead to reducing the implementation cost and avoid the use of current measurement that may have some disadvantages. The derived controller is validated by simulation performed in Psim software and experimental setup.

4.
ISA Trans ; 74: 111-119, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29336788

RESUMO

Speed ripple at low speed-high torque operation of Permanent Magnet Synchronous Machine (PMSM) drives is considered as one of the major issues to be treated. The presented work proposes an efficient PMSM speed controller based on Grey Wolf (GW) algorithm to ensure a high-performance control for speed ripple reduction at low speed operation. The main idea of the proposed control algorithm is to propose a specific objective function in order to incorporate the advantage of fast optimization process of the GW optimizer. The role of GW optimizer is to find the optimal input controls that satisfy the speed tracking requirements. The synthesis methodology of the proposed control algorithm is detailed and the feasibility and performances of the proposed speed controller is confirmed by simulation and experimental results. The GW algorithm is a model-free controller and the parameters of its objective function are easy to be tuned. The GW controller is compared to PI one on real test bench. Then, the superiority of the first algorithm is highlighted.

5.
Data Brief ; 7: 366-71, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26977439

RESUMO

Four years׳ behavioral data of thin-film single junction amorphous silicon (a-Si) photovoltaic (PV) modules installed in a relatively dry and sunny inland site with a Continental-Mediterranean climate (in the city of Jaén, Spain) are presented in this article. The shared data contributes to clarify how the Light Induced Degradation (LID) impacts the output power generated by the PV array, especially in the first days of exposure under outdoor conditions. Furthermore, a valuable methodology is provided in this data article permitting the assessment of the degradation rate and the stabilization period of the PV modules. Further discussions and interpretations concerning the data shared in this article can be found in the research paper "Characterization of degradation and evaluation of model parameters of amorphous silicon photovoltaic modules under outdoor long term exposure" (Kichou et al., 2016) [1].

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...