Patients with an Eisenmenger syndrome have an instuble hemodynamic status. During a general anaesthesia, the intracardiac shunt has to maintain the correct orientation and volume, adapted to each patient, in such a condition, to avoid the risk of hypoxemia and cardiac failure. The haemodynamic monitoring with a Swan Ganz catheter could be useful. But it is necessary to evaluate the advantage and the risks when the technique is used in these pathological circumstances. Moreover, when the cardiac output is measured with the thermodilution technique, the right-left intra cardiac shunt volume, is not taking into account. The continuous haemodynamic monitoring, with a simplified transoesophageal echo-Doppler system, as it was done in this case, allows appreciate the real quantitative variations of the shunt. In this way the more adequate calculation of some others haemodynamic parameters, over all the total systemic vascular resistances, allows a more precise therapeutic approach.


Assuntos
Anestesia , Complexo de Eisenmenger/complicações , Hemodinâmica/fisiologia , Monitorização Intraoperatória/métodos , Débito Cardíaco , Ecocardiografia Transesofagiana , Complexo de Eisenmenger/fisiopatologia , Feminino , Fibroma/cirurgia , Humanos , Histerectomia , Pessoa de Meia-Idade , Termodiluição