1.
Rev Sci Instrum ; 94(5)2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37232938

RESUMO

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. The spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

2.
Rev Sci Instrum ; 82(11): 113507, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22128975

RESUMO

Recent upgrades to the soft x-ray (SXR) array system on the DIII-D tokamak are described. The system consists of two 32-channel arrays at one toroidal location and three toroidally distributed 12-channel arrays. The 32-channel arrays have been completely rebuilt to allow the switching of SXR filters without breaking vacuum. The 12-channel arrays have had upgrades performed to detectors, view slits, and data acquisition. Absolute extreme ultraviolet (AXUV) photodiodes are used as detectors in all arrays, allowing detection of photons ranging in energy from 2 eV to 10 keV. In the fixed-filter arrays, 127 µm Be filters are used. In the variable-filter arrays, filter wheels are used to switch between five different possible pinhole/filter combinations.

3.
Rev Sci Instrum ; 80(12): 123506, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20073119

RESUMO

We describe a fast reciprocating Langmuir probe and drive system, which has four main new features: (1) use of high-temperature, vacuum, circuit boards instead of cables to reduce weight and increase to 21 the number of possible connections, (2) rotatable and removable shaft, (3) 10 tip construction with designed hardware bandwidth up to 10 MHz, and (4) a detachable and modular tip assembly for easy maintenance. The probe is mounted in a fast pneumatic drive capable of speeds approximately 7 m/s and approximately 20g's acceleration in order to reach the scrape-off layer (SOL) and pedestal regions and remain inserted long enough to obtain good statistics while minimizing the heat deposition to the tips and head in a power density environment of 1-10 MW/m2. The National Spherical Torus Experiment SOL features electron temperature, T(e) approximately 10-30 eV, and electron density, n(e) approximately 0.1-5x10(12) cm(-3) while the pedestal features n(e) approximately 0.5-1.5x10(13) cm(-3) and T(e) approximately 30-150 eV. The probe described here has ten tips which obtain a wide spectrum of plasma parameters: electron temperature profile T(e)(r), electron density profile n(e)(r) and Mach number profile M(r), floating potential V(f)(r), poloidal and radial electric field profiles E(theta)(r) and E(rho)(r), saturation current profile I(sat)(r), and their fluctuations up to 3 MHz. We describe the probe and show representative radial profiles of various parameters.