RESUMO
Aim: Currently, there is lack of data regarding rapid antigen detection (RAD) kits to detect SARS-CoV-2 B.1.617.2 virus. Objective: The purpose of this evaluation is to assess analytical sensitivity of 12 RAD kits against SARS-CoV-2 B.1.617.2. Study design: Analytical sensitivity was determined by limit of detection (LOD). A serial tenfold dilution set from a respiratory specimen collected from a COVID-19 patient infected by SARS-CoV-2 B.1.617.2 was used. RT-PCR was used as a reference method. Results: The LOD results showed that 11 and one RAD kits were 100- and 1000-fold less sensitive than RT-PCR respectively. Conclusion: The results showed that the RAD kits evaluated in this study may be used for first-line screening of the SARS-CoV-2 B.1.617.2 variant.
RESUMO
BACKGROUND: Numerous rapid antigen detection (RAD) kits for diagnosing COVID-19 patients are available in the market recently. OBJECTIVE: To compare analytical sensitivity and clinical sensitivity for the three commercially available RAD kits. STUDY DESIGN: Analytical sensitivity for the detection of SARS-CoV-2 virus was determined by limit of detection (LOD) using RT-PCR as a reference method. Clinical sensitivity was evaluated by using respiratory specimens collected from confirmed COVID-19 patients. RESULTS: The LOD results showed that the three RAD kits varied from 102-105 fold less sensitive than RT-PCR. Clinical sensitivity of RAD kits ranged from 22.9 %-71.4 % for detecting specimens from COVID-19 patients. CONCLUSIONS: Although RAD kits were less sensitive than RT-PCR, understanding the clinical characteristics of different RAD kits can guide us to obtain suitable specimens for testing. The likelihood of positive results for RAD kits will be higher.